Neqsim power generation is an AI agent skill from the GitHub repository equinor/neqsim. Power generation patterns for NeqSim. USE WHEN: modeling gas turbines, steam turbines, HRSG, combined cycle systems, waste heat recovery, or calculating fuel gas consumption and thermal efficiency. Covers GasTurbine, SteamTurbine, HRSG, CombinedCycleSystem classes and heat integration with PinchAnal

How to use this skill

Skill file

Power Generation with NeqSim

Integrated compression supplies

For a common compressor shaft, use CompressorPowerTrain with

directDrive(GasTurbineUnit), electricDrive(ElectricMotor) or

gasElectricDrive(GasTurbineUnit, Generator, ElectricMotor) and attach it with

shaft.setPowerTrain(...). Read the

executable matching guide.

Use actual compressor duty, gearbox efficiency, motor/VFD and generator inverse

maps, supply caps and auxiliaries. Keep turbine-generator rpm separate from motor

rpm. Check the shaft report AND the supply result: isPowerFeasible() tests power;

isFeasible() also rejects a below-minimum-load turbine. A shortfall never makes

the compressor's requested discharge physically achievable.

Use GasTurbinePerformanceMap.setPartLoadHeatRateTable(loadFractions, factors)

for supplied part-load data; load is relative to site-available shaft power and

the last point must be (1, 1). Keep ambient corrections separate and record

data provenance. Catalogue/generic maps and passing synthetic balance tests do

not qualify a turbine package. Follow issue #4909 for component maps, output-speed

surfaces, dynamic controls and independent validation. For shared electricity

use the existing energy-bus solver; this dedicated-train adapter does not dispatch

motor/generator energy ports or create a material exhaust stream.

Guide for modeling power generation equipment — gas turbines, steam turbines,

heat recovery steam generators (HRSG), and combined cycle systems.

When to Use This Skill

Key NeqSim Classes

| Class | Package | Purpose |

|-------|---------|---------|

| GasTurbine | process.equipment.powergeneration | Gas turbine with compressor, combustor, expander |

| GasTurbineVendorPerformance | process.equipment.powergeneration | Vendor ISO-rated GT driver — fuel + CO2 matched to a shaft/electric load demand |

| SteamTurbine | process.equipment.powergeneration | Steam expansion turbine |

| HRSG | process.equipment.powergeneration | Heat recovery steam generator |

| CombinedCycleSystem | process.equipment.powergeneration | GT + HRSG + ST integrated system |

| PinchAnalysis | process.equipment.heatexchanger.heatintegration | Pinch analysis for heat integration |

| HeatStream | process.equipment.heatexchanger.heatintegration | Hot/cold stream for pinch analysis |

Vendor-performance GT driver — matched fuel & power (PREFERRED for drivers)

For a real mechanical-drive or generator gas turbine (e.g. a GE LM2500 driving a

compressor or an AC generator), the built-in simple-cycle GasTurbine is a rough

model and is unreliable for net power / efficiency. Use

GasTurbineVendorPerformance instead: it takes a load demand and returns the

fuel rate and CO2 matched to that load using the fuel gas's rigorous ISO 6976

LCV and stoichiometric carbon.

GasTurbineVendorPerformance gt = new GasTurbineVendorPerformance("GT driver", fuelStream);
gt.setVendorRating(22.4, "MW", 0.37);        // ISO base power, base LHV efficiency
gt.setAmbientDerating(15.0, 0.007);          // design ambient C, power lapse /degC
gt.setSiteAmbientTemperature(15.0);
gt.setPartLoadHeatRateCoefficient(0.15);     // heat-rate rise at part load
gt.setLoadDemand(compressor.getPower("kW"), "kW");  // <-- the process power need
gt.run(UUID.randomUUID());
double fuel = gt.getFuelFlowRate("kg/hr");
double co2  = gt.getCO2EmissionRate("tonne/day");
double loadFrac = gt.getLoadFraction();      // vs site-rated MAX (bottleneck basis)
double spareKW  = gt.getSiteRatedPower("kW") - compressor.getPower("kW");

Matching rule (do this, never hardcode fuel/power):

(compressor.getPower("kW")), so fuel and CO2 track the process automatically.

For a closed mass balance, physically tap it with a Splitter

(setFlowRates([-1.0, fuelKgHr], "kg/hr")) so sales gas = gas − fuel.

priority, do NOT hardcode: (1) measured historian tag (tagreader/Seeq

main-switchboard active power) — the correct primary source; (2) STID

generator installed rating × documented load factor if STID exposes a

structured rating; (3) a clearly-flagged fallback. STID's structured

rating/load fields are frequently empty (they live in the datasheet PDF),

so the historian is the right source for the actual load — record the chosen

source in results.json so the value is never an unsourced magic number.

getSiteRatedPower, getLoadFraction, spare power, and N+1 firm capacity for

the generators; the highest-loaded unit is the power bottleneck.

1. Gas Turbine

// Fuel gas stream — the combustion air is generated internally by the GasTurbine.
SystemInterface fuelGas = new SystemSrkEos(273.15 + 25, 30.0);
fuelGas.addComponent("methane", 0.90);
fuelGas.addComponent("ethane", 0.06);
fuelGas.addComponent("propane", 0.02);
fuelGas.addComponent("nitrogen", 0.02);
fuelGas.setMixingRule("classic");

Stream fuelStream = new Stream("Fuel Gas", fuelGas);
fuelStream.setFlowRate(5000.0, "kg/hr");
fuelStream.run();

// Simplified Brayton-cycle gas turbine: internal air compressor + combustor + expander + cooler.
GasTurbine gt = new GasTurbine("GT-001", fuelStream);
gt.combustionpressure = 18.0;      // firing / combustion pressure [bara]
gt.setExcessAirFactor(2.5);        // excess air over stoichiometric (caps firing temperature)
gt.run();

double power_MW = gt.getPower("MW");           // net shaft power (expander - air compressor)
double rejectHeat_W = gt.getHeat();           // heat rejected by the exhaust cooler [W]
double idealAFR = gt.calcIdealAirFuelRatio(); // stoichiometric air/fuel mass ratio

The legacy GasTurbine is a simplified thermodynamic Brayton model. For

vendor-rated power, part-load + ambient correction, degradation, emissions,

and dispatch use GasTurbineUnit + GasTurbineCatalog (see section 7).

Inverse (power-demand) mode — size fuel to a load

GasTurbine can also run inverse: instead of fuel-in → power-out, give it a

required net power and it sizes the fuel-gas flow so the turbine delivers that

load from the fuel lower heating value (LCV) and its thermalEfficiency. Use

this when a compressor/generator load is known and you want the matching fuel

(and CO₂) consumption as the process solves.

GasTurbine gt = new GasTurbine("GT-driver", fuelStream);
gt.setThermalEfficiency(0.36);          // REQUIRED (> 0) for power-demand mode
gt.setRequiredPower(18.0, "MW");        // driven load; unit: "W", "kW" or "MW"
gt.run();

double fuel_kghr = gt.getFuelFlowRate("kg/hr");  // fuel-gas consumption sized to the load
double fuel_Sm3d = gt.getFuelFlowRate("Sm3/day");
boolean inverse  = gt.isPowerDemandMode();       // true
double reqW      = gt.getRequiredPower();         // required power in Watts

setRequiredPower(0.0, ...) returns the turbine to the normal fuel-to-power

mode. Power-demand mode throws if thermalEfficiency <= 0. For vendor-accurate

fuel/CO₂ vs a load demand, prefer GasTurbineVendorPerformance (top of this

skill) or the catalog-driven GasTurbineUnit (section 7).

Reading CO₂ off a load-driven turbine — three traps

addDrivenLoad(compressor) is the cleanest way to size fuel to a real duty: the

turbine sums Compressor.getPower() over its loads each solve, so the fuel gas

tracks the process. Getting an emission number out of it has three traps.

GasTurbine gt = new GasTurbine("GT-driver");
gt.setInletStream(fuelStream);
gt.setThermalEfficiency(0.32);      // REQUIRED
gt.addDrivenLoad(exportCompressor); // loads must be run before the turbine
gt.run();
double fuel_kghr = gt.getFuelFlowRate("kg/hr");
  1. Pseudo-components abort the combustion balance. The stoichiometry asks the

element database for each hydrocarbon's C and H count, and a characterised

fluid's C7P/C10A… pseudo-components are not in it. Older builds threw

Element:getNumberOfElements - Input C component not in element database;

current builds estimate the atom counts from molar mass. Either way, prefer

building the fuel from real named components (`nitrogen, CO2, methane,

ethane, propane, i-butane, n-butane, i-pentane, n-pentane, n-hexane`) —

renormalising an export-gas composition onto that set typically captures

>99.8 mol% and matches what a plant actually burns.

  1. The combustion air carries CO₂ of its own. Fluid.create("combustion air")

is an unnormalised N2 0.78084 / O2 0.20946 / CO2 0.033 / water 0.1, i.e.

2.9 mol% CO₂ against atmospheric 0.04 %. Subtract the air-borne CO₂

(gt.airStream) before quoting an exhaust CO₂, or the number is inflated

(75 % in one 1.7 MW case).

  1. Cross-check against a carbon balance. The defensible number is

fuel_moles × (C atoms per mole fuel) × 44.01 g/mol. Compare it with the

exhaust read; agreement to <1 % is the check that both the fuel sizing and the

exhaust composition are right. Do this before putting a CO₂ profile in a

report or a STEA export.

2. Steam Turbine

// Steam at high pressure and temperature
SystemInterface steam = new SystemSrkEos(273.15 + 540, 100.0);
steam.addComponent("water", 1.0);
steam.setMixingRule("classic");

Stream steamFeed = new Stream("HP Steam", steam);
steamFeed.setFlowRate(50000.0, "kg/hr");

SteamTurbine st = new SteamTurbine("ST-001", steamFeed);
st.setOutletPressure(0.1);  // Condenser pressure in bara
st.setIsentropicEfficiency(0.85);
st.run();

double stPower = st.getPower("MW");
double outletT = st.getOutletStream().getTemperature() - 273.15;

3. Heat Recovery Steam Generator (HRSG)

// Recover heat from a hot turbine-exhaust gas stream. The HRSG takes a single
// hot-gas inlet stream; steam conditions are set on the unit.
HRSG hrsg = new HRSG("HRSG-001", exhaustGasStream);
hrsg.setSteamPressure(40.0);            // bara
hrsg.setSteamTemperature(400.0, "C");
hrsg.setFeedWaterTemperature(105.0, "C");
hrsg.setApproachTemperature(15.0);
hrsg.run();

double duty_W = hrsg.getHeatTransferred();
double steamFlow = hrsg.getSteamFlowRate("kg/hr");
double stackT = hrsg.getGasOutletTemperature() - 273.15;  // °C

4. Combined Cycle System

// Integrated GT + HRSG + ST. The sub-units are built internally from the fuel
// gas stream — configure conditions through the setters below.
CombinedCycleSystem ccgt = new CombinedCycleSystem("CCGT", fuelStream);
ccgt.setCombustionPressure(18.0);
ccgt.setSteamPressure(40.0);
ccgt.setSteamTemperature(400.0, "C");
ccgt.setGasTurbineEfficiency(0.38);
ccgt.setSteamTurbineEfficiency(0.85);
ccgt.run();

double totalPower = ccgt.getTotalPower("MW");
double gtPower_W = ccgt.getGasTurbinePower();
double stPower_W = ccgt.getSteamTurbinePower();
double combinedEfficiency = ccgt.getOverallEfficiency();
// Typical: 55-62% for modern CCGT

5. Heat Integration (Pinch Analysis)

// Identify minimum utility requirements for a process
PinchAnalysis pinch = new PinchAnalysis("Plant Heat Integration");

// Add hot streams (need cooling)
pinch.addHotStream(new HeatStream("Reactor effluent", 250.0, 60.0, 5000.0));
pinch.addHotStream(new HeatStream("Column overhead", 120.0, 40.0, 3000.0));
pinch.addHotStream(new HeatStream("Product cooler", 80.0, 30.0, 1500.0));

// Add cold streams (need heating)
pinch.addColdStream(new HeatStream("Feed preheater", 25.0, 180.0, 4500.0));
pinch.addColdStream(new HeatStream("Reboiler", 150.0, 160.0, 2000.0));

// Set minimum approach temperature
pinch.setMinApproachTemperature(10.0);  // degrees C
pinch.run();

double minHotUtility = pinch.getMinHotUtility();   // kW
double minColdUtility = pinch.getMinColdUtility();  // kW
double pinchTemp = pinch.getPinchTemperature();     // °C

6. Emissions from Power Generation

// Fuel gas composition determines CO2 emissions
// CH4 + 2O2 -> CO2 + 2H2O
// C2H6 + 3.5O2 -> 2CO2 + 3H2O
// C3H8 + 5O2 -> 3CO2 + 4H2O

// Approximate: 2.75 kg CO2 per kg natural gas (varies with composition)
double fuelRate_kg_hr = fuelStream.getFlowRate("kg/hr");
double co2Factor = 2.75;  // kg CO2 / kg fuel (adjust for actual composition)
double co2_tonnes_yr = fuelRate_kg_hr * co2Factor * 8760 / 1e6;

// For a rigorous full-carbon-balance CO2, NOx, and methane-slip estimate use the
// catalog-driven GasTurbineUnit (section 7): gt.getCO2EmissionKgPerHr().

7. Right-Sizing & Dispatch (gasturbine sub-package)

For late-life or turndown studies where the question is *"which turbines, how

many, and at what load?"* — use the catalog-driven classes under

neqsim.process.equipment.powergeneration.gasturbine. These integrate directly

with ProcessSystem and link to Compressor.getPower() via the

PowerDemandConsumer interface.

| Class | Purpose |

|-------|---------|

| GasTurbineCatalog | Loads the bundled gas_turbine_catalog.csv (14 aero + industrial models: LM2500, LM2500PLUS_G4, LM6000PF/PG, RB211_6562, Trent 60, SGT-700/750, Centaur 50, Taurus 60/70, Mars 100, Titan 130/250) |

| GasTurbineSpec | Immutable rating point (rated MW, ISO heat rate, exhaust flow/T, NOx, mass) |

| GasTurbinePerformanceMap | Part-load + ambient correction (aero vs industrial polynomials, min-load fraction) |

| GasTurbineDegradation | Recoverable + non-recoverable fouling vs fired hours, offlineWash() full reset and onlineWash(effectiveness) partial recovery |

| GasTurbineWashPlanner | Wash-interval economics: sawtooth with partial recovery, extra fuel/CO2/cost per interval, optimal interval, payback of a permanent on-line wash installation |

| GasTurbineEmissions | Full-carbon-balance CO2, NOx, methane slip from fuel composition |

| CO2TaxSchedule | Loads co2_tax_norway.csv (2020–2040 NOK/tonne, CO2 tax + EU ETS), linear interpolation |

| GasTurbineUnit | TwoPortEquipment — runs inside a ProcessSystem, accepts fuel Stream, aggregates Compressor shaft load via addPowerConsumer |

| TurbineDispatchOptimizer | Picks the cheapest feasible on/off combination (brute-force ≤8 units, merit-order above) with N+1 reserve |

| LateLifeRetrofitStudy | Year-by-year NPV / CO2-avoided / payback for baseline vs retrofit fleet over a declining demand profile |

Water-wash interval and permanent-wash business case

When the question is *"how often should we wash, and is a permanent on-line wash

skid worth it?"*, drive GasTurbineWashPlanner from the plant's measured

corrected-efficiency trend rather than a generic OEM rate. An energy-management

system usually trends "corrected turbine efficiency" in percentage points;

lossRateFromCorrectedEfficiencyTrend(ppPer1000FiredHours, cleanEfficiencyPercent)

converts that KPI slope into the fractional loss rate the planner needs.

GasTurbineWashPlanner planner = new GasTurbineWashPlanner();
planner.setShaftPowerW(22.1e6);
planner.setBaselineHeatRateKJPerKWh(10090.0);
planner.setFuelLhvKJPerSm3(36500.0);          // from Standard_ISO6976 getValue("LCV","kJ/m3")
planner.setCo2PerSm3Fuel(2.06);               // carbon balance on the fuel composition
planner.setEfficiencyLossRatePerFiredHour(
    GasTurbineWashPlanner.lossRateFromCorrectedEfficiencyTrend(0.24, 92.0));
planner.setRecoveryEffectiveness(0.40);       // on-line ~0.3-0.5, off-line crank ~0.85-0.95
planner.setOutageHoursPerWash(0.0);           // on-line washing has no outage
planner.setWashCostPerEvent(20000.0);
planner.setFuelValuePerSm3(3.0);
planner.setCo2PricePerTonne(CO2TaxSchedule.loadDefault().getTotalNOKPerTonne(2026));
GasTurbineWashPlanner.WashPlan best = planner.optimize(24.0, 4380.0, 12.0);
double payback = GasTurbineWashPlanner.paybackYears(6.0e6, currentPractice, best);

Gotchas:

with an explicit deferment fraction and report the payback excluding it as

the headline; a fully-deferred outage makes crank washing look arbitrarily bad.

washing is already the best off-line practice — the lever is on-line washing,

not a shorter crank cycle.

amplitude, off-line washing resets the residual (1-e)rT/e that an imperfect

on-line wash leaves behind.

Catalog & site-corrected available power

GasTurbineSpec spec = GasTurbineCatalog.get("LM2500");
GasTurbineUnit gt = new GasTurbineUnit("GT-A", fuelStream, spec);
gt.setAmbientTemperatureK(273.15 + 30.0);  // hot day derate
gt.setDemandedPower(15.0e6);                // 15 MW shaft
gt.run(UUID.randomUUID());
double avail_MW = gt.getAvailablePowerW() / 1.0e6;
double load     = gt.getLoadFraction();
double co2_tph  = gt.getCO2EmissionKgPerS() * 3.6;

Site rating, exhaust limit and waste heat (ambient-dependent driver)

GasTurbinePerformanceMap map = GasTurbinePerformanceMap.fromSpec(spec);
map.setSiteRatingFromPowerPoints(new double[] {5, 16}, new double[] {41.4e6, 39.3e6}, spec.getRatedPowerW()); // vendor points
map.setExhaustTemperatureRisePerKelvin(0.5);        // or setSiteExhaustTemperatureTable(...)
gt.setPerformanceMap(map);
gt.setMaxExhaustTemperatureK(820.0);                  // power cut 1 %/K of full-load exhaust-T excess
double pAt30C = gt.getAvailablePowerAtAmbientC(30.0); // no run needed; W
double[] curve = gt.getSiteRatingCurveW(new double[] {-5, 5, 15, 25});
gt.setAmbientTemperatureC(30.0); gt.setDemandedPower(15.0e6); gt.run();
double fuelKgHr = gt.getFuelMassFlowKgPerHr();
double whruW = gt.getWasteHeatRecoveryDutyW(150.0 + 273.15, 0.85);  // exhaust heat above stack

PlatformPowerSystem dispatches GT generators + power from shore (+ optional steam bottoming yield, e.g. 0.25

MWe/MW) at an ambient temperature: evaluate(T_K, electricDemandW, heatDemandW) and evaluateAcrossAmbient(...)

give capacity, deficit, N-1 margin, WHRU heat to the process, fuel and CO2 (toJson()). A mechanical-drive GT on a

compressor shaft is modelled with CompressorShaft.setGasTurbineUnitDriver (see neqsim-rotating-equipment-design).

The vendor table overrides the linear lapse; keep the catalog only for slopes when vendor data exist.

Linking turbine shaft to compressor demand

Each GasTurbineUnit aggregates the live shaft demand from any number of

Compressor objects in the same flowsheet — the dispatcher reads it on every

run():

ProcessSystem plant = new ProcessSystem();
plant.add(exportCompressor);     // existing Compressor
plant.add(injectionCompressor);
GasTurbineUnit gt = new GasTurbineUnit("GT-A", fuelStream,
        GasTurbineCatalog.get("LM2500"));
gt.addPowerConsumer(exportCompressor);
gt.addPowerConsumer(injectionCompressor);
plant.add(gt);
plant.run();   // gt sums Compressor.getPower() automatically

Fleet dispatch with N+1 redundancy

List<GasTurbineUnit> fleet = Arrays.asList(gt1, gt2, gt3);  // each is a GasTurbineUnit
TurbineDispatchOptimizer disp = new TurbineDispatchOptimizer(
        /*fuelPriceNOKPerKg*/ 4.5,
        /*co2CostNOKPerTonne*/ 1500.0);
disp.setRequireNplusOne(true);
TurbineDispatchOptimizer.DispatchResult r = disp.dispatch(fleet, 18.0e6);
if (r.feasible) {
    System.out.println(r.summary());   // running units, load, NOK/hr
}

Retrofit NPV vs baseline

double[] demandMW = new double[15];
for (int i = 0; i < 15; i++) demandMW[i] = Math.max(8.0, 20.0 - i * 0.8);

LateLifeRetrofitStudy study = new LateLifeRetrofitStudy(
        baselineFleet,    // e.g. 2x LM6000PF
        retrofitFleet,    // e.g. 2x SGT-700
        demandMW,
        /*startYear*/ 2026,
        CO2TaxSchedule.loadDefault(),
        /*fuelPriceNOKPerKg*/ 4.5);
study.setRetrofitCapexMNOK(800.0);
study.setDiscountRate(0.08);
study.setAnnualOperatingHours(8000);
LateLifeRetrofitStudy.RetrofitResult res = study.run();
System.out.println("NPV (MNOK):       " + res.npvMNOK);
System.out.println("CO2 avoided (t):  " + res.totalCO2AvoidedTonne);
System.out.println("Payback (yr):     " + res.simplePaybackYear);

When to choose this sub-package vs the legacy `GasTurbine`

| Use legacy GasTurbine | Use GasTurbineUnit + catalog |

|-------------------------|--------------------------------|

| You model the GT thermodynamically (compressor + combustor + expander) and care about exhaust composition into an HRSG | You are doing right-sizing, dispatch, retrofit, or fleet-level CO2/NPV studies and want vendor rating points, part-load + ambient correction, degradation, and N+1 |

| Combined-cycle integration where exhaust gas feeds an HRSG | Late-life turndown, replacing oversized turbines, CO2-tax sensitivity |

Flue-gas composition, NOx, SO2 and adiabatic flame temperature — `CombustionCalculator`

For the exhaust (flue-gas) composition and pollutant rates of any turbine, burner, or fired

heater, use neqsim.process.util.combustion.CombustionCalculator. It deliberately splits the two

physically different families of exhaust species — **do not use a single Gibbs reactor for the whole

problem:**

(not equilibrium-limited at the exhaust), so an exact element balance of full combustion with

excess air is used: all fuel C -> CO2, all fuel H -> H2O, all fuel S (e.g. H2S) -> SO2.

reactor over-predicts NO at flame temperature and returns ~0 at stack temperature, so it is the

wrong tool. They come from public EMEP/EEA-style emission factors (g per GJ fuel LHV), which

the caller replaces with a vendor guarantee or CEMS value.

mixture enthalpy so the released LHV heats the products from 298 K) — excess air lowers it via

inert dilution.

SystemInterface fuel = new SystemSrkEos(288.15, 20.0);
fuel.addComponent("methane", 0.95);
fuel.addComponent("ethane", 0.03);
fuel.addComponent("H2S", 0.0002);
fuel.setMixingRule("classic");

CombustionCalculator.CombustionResult r = new CombustionCalculator(fuel)
    .setFuelFlowRate(7896.0)         // kg/hr (total combusted fuel)
    .setExcessAirRatio(3.2)          // GT ~3-3.5 -> ~14-15 vol% exhaust O2; burner ~1.05-1.2
    .setBurnerType(CombustionCalculator.BurnerType.GAS_TURBINE_DLE) // sets typical NOx/CO for the technology
    .setNoxFactorGPerGJ(130.0)       // optional: override with a vendor/CEMS value AFTER setBurnerType
    .setCoFactorGPerGJ(30.0)
    .setAssumedFuelH2sPpmv(5.0)      // used only if the fuel carries no sulphur
    .calculate();

r.getFlueMoleFraction("CO2");         // exhaust CO2 mole fraction
r.exhaustO2VolPercent;                // ~14 vol% for a GT
r.pollutantPpmv.get("NOx");           // NOx ppmv (emission-factor basis)
r.getMassRateKgPerHr("SO2");          // SO2 kg/hr (fuel-sulphur stoichiometric)
r.adiabaticFlameTemperatureK;         // rigorous NeqSim energy balance
String json = r.toJson();

Burner technology (BurnerType) — NOx and CO are combustion-technology-dependent, so the

calculator ships a small burner database that sets typical factors: CONVENTIONAL (130/30 g/GJ),

LOW_NOX (60/40), ULTRA_LOW_NOX (30/50), GAS_TURBINE_CONVENTIONAL (300/40),

GAS_TURBINE_DLE (90/30), GAS_TURBINE_WET (130/60). A low-NOx technology trades lower NOx for

somewhat higher CO. These are screening defaults on a natural-gas basis — always override with a

vendor guarantee or CEMS value when available. Accuracy also depends on fuel composition (H2 raises

flame temperature and NOx), excess air / O2, combustion-air preheat, load, humidity / water-steam

injection and the reference-O2 reporting basis (3% for heaters, 15% for GT); the stoichiometric

majors and SO2 are exact, only the emission-factor NOx/CO carry this technology sensitivity.

stoichAirFuelMassRatio / airFuelMassRatio, fuelLhvKJperKg, fuelEnergyGJperHr and the full

massRateKgPerHr map (NOx key is NOx_as_NO2) are also returned. This pairs with

GasTurbineVendorPerformance / GasTurbine (which give the fuel rate) and with the CO2 accounting

above. The same setBurnerType(...) / emission-factor NOx/CO is available on the FurnaceBurner

unit operation via setUseEmissionFactorPollutants(true) or setBurnerType(...).

Stack-emission reporting (dry basis, reference O2, mg/Nm3, Nm3/hr, t/yr)

For a regulatory stack-emission report (EU IED / EN 14792 NOx, EN 15058 CO, EN 14791 SO2) the

concentration must be dry, at a reference O2, in mg/Nm3 — not wet ppmv. The calculator does this

chain correctly:

then carries pollutantPpmvAtReferenceO2 and pollutantMgPerNm3AtReferenceO2 (the value directly

comparable with a permit limit). The reference-O2 correction C_ref = C*(20.9-O2ref)/(20.9-O2meas)

is applied on the dry concentration at the dry exhaust O2 (exhaustO2VolPercentDry) — the

20.9 % basis is dry air, so mixing wet ppmv with it (a common mistake) is wrong.

conversion and the normalized flue-gas flow flueGasNm3PerHrWet / flueGasNm3PerHrDry. Sanity

check: 1 ppmv NOx-as-NO2 ~ 2.05 mg/Nm3, CO ~ 1.25, SO2 ~ 2.86 at 0 degC.

report). pollutantPpmv is wet, pollutantPpmvDry is dry — always compare limits on the dry / ref-O2

outputs.

SO3 / acid dew point, other pollutants, NOx routes, actual stack conditions

The extended stack-emission physics (all optional, 0 / off by default so clean-gas results are unchanged):

(typically 1–5 %). The result then reports SO3, the acidDewPointC (Verhoff-Banchero sulfuric-acid dew

point) and always the waterDewPointC. The acid dew point (often 120–150 °C) is well above the water dew

point and sets the cold-end / stack minimum metal temperature to avoid corrosion.

setN2oFactorGPerGJ add particulates, methane slip, non-methane VOC and N2O (relevant for liquid/dual-fuel,

lean-premix GT, and reciprocating gas engines). Each appears in massRateKgPerHr, massRateTonnesPerYear,

and (for the gaseous species) the ppmv / mg/Nm3 maps.

setPromptNoxFactorGPerGJ (Fenimore) and setFuelNoxFactorGPerGJ (fuel-bound N). The result carries

noxThermalKgPerHr / noxPromptKgPerHr / noxFuelKgPerHr and the total in massRateKgPerHr["NOx_as_NO2"].

heat-recovery-outlet temperature, NOT the adiabatic flame temperature) gives the actual volumetric flow

stackActualM3PerHr (Am³/hr); adding setStackDiameterM(1.5) gives the stack-exit stackVelocityMPerS.

setStackPressureBara sets the basis for the actual flow and the dew-point partial pressures.

Field calibration and fuel-composition / turndown studies

calibrateNoxFromMeasuredPpmv(measuredPpmv, measuredExhaustO2VolPercent) (and the CO analogue)

set a multiplicative factor so the model reproduces the measurement and scales to other loads on a

fuel-energy basis. This anchors magnitude before predicting other conditions.

AFR, LHV and flame temperature. Optional enableThermalNoxScaling(refFlameTempK) scales NOx with the

Zeldovich temperature dependence (Ta ~ 38000 K) — directionally correct (hotter flame -> more NOx).

mode** — lambda floats from the fixed air, the fuel rate and the fuel composition, so you can lower the

fuel rate and watch lambda rise (leaner), exhaust O2 rise and NOx fall. The result flags airDriven

and subStoichiometric (lambda < 1, air-starved — outside the valid screening range). Caveat:

enableThermalCoScaling(...) must not be used to predict CO over an excess-air (lambda) sweep — CO

vs lambda is U-shaped (O2-driven), and the flame-T scaling predicts the wrong sign there; field-calibrate

CO against measured CO-vs-O2 for load/turndown studies.

Physics basis / limits (state-of-the-art alignment): stoichiometry + excess air (Turns; GPSA;

API 560/537), Zeldovich thermal NOx (Ta ~ 38000 K; Lefebvre), EMEP/EEA + EPA AP-42 emission factors,

EPA Method 19 / EN 14792 reference-O2 correction, Verhoff-Banchero acid dew point. Prompt/fuel-N NOx and

N2O/PM/CH4/VOC are available as optional emission factors; the SO3 split and acid/water dew points and the

actual stack conditions are modelled. The one remaining physics limit is high-temperature dissociation in

the adiabatic flame temperature (like a no-dissociation H&MB simulator it slightly over-predicts near

stoichiometric). For rigorous flame chemistry use Cantera/CHEMKIN with a validated mechanism (GRI-Mech 3.0) —

this class is the fast, auditable engineering-screening model consistent with how process simulators estimate

emissions.

Combined-cycle retrofit (HRSG + SteamTurbine on top of the fleet)

To evaluate a bottoming cycle on top of a GasTurbineUnit retrofit fleet, feed

the synthesised exhaust into the legacy HRSG + SteamTurbine. Use the

per-unit exhaust mass flow and temperature from GasTurbineSpec (corrected by

GasTurbinePerformanceMap if needed) to build an exhaust Stream, then size

the bottoming cycle and add its power output to the retrofit LateLifeRetrofitStudy

result as an annual energy credit (extra MWh × fuel-equivalent × CO2 factor).

The 20-year rightsizing notebook (see below) demonstrates this pattern in

section 10.

Reservoir + pipeline-driven shaft demand

Instead of a synthetic linear decline, drive the compressor shaft load from a

physics-based reservoir + flow line model. A simple gas-law material balance on

the reservoir gives (P_res, T_res) each year; a PipeBeggsAndBrills riser

plus flow line gives arrival pressure at the platform; the export compressor

suction pressure then sets shaft demand which the GasTurbineUnit /

TurbineDispatchOptimizer resolves. This couples the late-life study to real

field decline (recovery factor, reservoir size uncertainty) and is the right

pattern when CO2 tax and turbine count must be evaluated against an uncertain

production profile rather than a stipulated demand curve. Section 11 of the

20-year rightsizing notebook implements this end-to-end.

Worked example

See CODE0

for a complete 20-year late-life right-sizing study: catalog + site correction,

degradation, dispatch with N+1, LateLifeRetrofitStudy with CO2TaxSchedule,

HRSG + steam-turbine combined-cycle extension, and reservoir-driven demand.

Applicable Standards

| Standard | Scope |

|----------|-------|

| ISO 2314 | Gas turbine acceptance tests |

| IEC 60034 | Rotating electrical machines |

| API 616 | Gas turbines for petroleum industry |

| API 611/612 | Steam turbines |

| ASME PTC 22 | Gas turbine power performance |

| ASME PTC 6 | Steam turbine performance |

Capacity of a platform power system against ambient (field-study pattern)

Use when the question is "will power capacity bind?" for a field profile (verified on a FPSO with a mechanical-drive injection turbine and two generator sets):

  1. Take the driver ratings from the debottlenecking or datasheet source as sustainable shaft power at a stated ambient (for example 41.4 MW at 5 C and 39.3 MW at 16 C) and fit a lapse per K above the reference. Cross-check the lapse with GasTurbinePerformanceMap.fromSpec(GasTurbineCatalog.get("SGT_750")): the catalog gave 0.205 MW/K against 0.196 from the vendor numbers, and 0.65 %/K for LM2500PLUS_G4. The catalog level is generic (41 MW ISO), so keep the vendor level and use the catalog only for the slope.
  2. Rate against the measured hourly ambient distribution; report utilisation at the hot design day, the mean over the distribution and the gas rate at which the rating is reached at 5 C and at 16 C.
  3. Do not read the certified train power on a compressor datasheet as the limit; it is the duty at the guarantee point.
  4. Electrical load: calibrate to measured generator output and scale the drivers that change (water injection power with injection rate and pressure, recompressors from the model); keep the design offloading step as the peak and the measured p99 minus mean as the empirical peak. Report the N+1 margin as peak load over one generator at hot ambient, not as a production limit.
  5. Heat: demand from the model heaters plus the study utility loads, supply from the vendor WHRU duty against turbine load; check whether both generators must run for heat, which conflicts with a standby unit.
  6. Fuel gas follows the turbine load; the process model usually carries a constant fuel gas flow, so report the fuel change separately and compare with the forecast fuel.

Note: jneqsim 3.5 has no gasturbine sub-package; run the catalog cross-check in an environment with a recent jar (3.18 in the shared venv), not in the model environment.

Added exhaust heat recovery for a heating-medium (HM) circuit (retrofit pattern)

Use when the question is "can we take more heat from a gas-turbine exhaust to cut electric-boiler or fired-heater duty?" (verified on an NCS field centre with two LM2500+ class drivers, an OTSG feeding a steam turbine and an electrode boiler on a 136/152 C water HM loop).

  1. Source term from the historian, not the catalog. Fit exhaust mass flow and turbine exit temperature against load from GT-on hours (flow 77 kg/s and 505 C at 94 % load). GasTurbineCatalog LM2500PLUS_G4 gave -10 % flow / -2 % temperature versus the aged measured units; keep the measured fit and use the catalog only for the slope.
  2. Heat above a minimum gas outlet temperature: Q = m * (h(T_exh) - h(T_out_min)) with T_out_min = HM return + 14 K pinch (about 150 C for a 136 C return). Use SRK or CoolProp on the combusted fuel gas; per turbine this is about 30 MW at 94 % load, five to seven times a typical 4-6 MW HM load.
  3. Coil location sets the size. A coil after an existing OTSG (stack end, gas about 173 C) has LMTD about 17 K and needs about 6x the area and 12x the weight of a hot-end coil upstream of the OTSG (LMTD about 325 K). Size with A = Q / (U * LMTD), U about 28 W/m2K external area for a finned water coil, and compare both before costing.
  4. Hot-end coil trades against steam power. If an OTSG/steam turbine is in service, heat to the coil removes yield MWe per MW (measured 0.254 MWe/MW from ST output over heat to steam); with the OTSG out of service it costs nothing. Net electricity displaced = Q_HM / eta_EB - yield x Q_HM x (share of time OTSG in service). Check the OTSG state first - a long outage can be worth more than the project.
  5. Validate the exhaust model on the steam side: heat to steam (feedwater to steam enthalpy) divided by exhaust enthalpy drop to the OTSG outlet should close within 1-2 %; it did (0.996).
  6. Back-pressure penalty: about 0.2-0.6 % heat rate per 10 mbar added exhaust dp; extra fuel gas and CO2 are small (about 1.5 GWh/yr per 6.6 mbar) but need OEM acceptance. Add the dp only for the new coil, not the existing path.
  7. Value depends on the share of the HM load that the electric boiler actually supplies: the measured WHRU duty is not the EB duty. Get the EB electric power history before giving a final value; break-even was about 3.1 MW EB-served load post-tax.
  8. CO2 depends on the grid factor: on a Power-from-Shore platform the avoided CO2 is small at the Norwegian average factor (20-25 g/kWh, about 0.5 kt/yr for 30 GWh/yr) and large at a marginal factor (300 g/kWh, about 9 kt/yr); report both and the abatement cost on each basis.
  9. Tag naming pattern on the NCS field centre historian: OSF-27-NRB -0831A (GT load %), OSF-27-NRA -0831A (exhaust flow), OSF-27-TI -275 (exhaust T), OSF-55-FIC -0671 (OTSG feedwater), OSF-55-TY -0685 (OTSG outlet T), OSF-55-XI -0626 (steam turbine MW), OSF-41-* (HM system). Narrow prefix searches (OSF-27-*) work; broad OSF-* searches time out.

Related: CODE0 for utility targeting and CODE1 for the electricity/CO2 side.

Common Pitfalls

| Pitfall | Solution |

|---------|----------|

| Unrealistic efficiency (>45% simple cycle) | Typical: 30-40% simple cycle, 55-62% combined cycle |

| Missing air stream for gas turbine | GT requires both fuel and combustion air |

| Steam below saturation in turbine outlet | Check for wet steam — may need superheat or extraction |

| Pinch analysis with wrong units | HeatStream uses °C for temperature, kW for duty |

| Ambient derate "does nothing" for a capped turbine | min(site rating, operating cap): a fixed cap (e.g. a 27.5 MW user/mechanical cap, an island-balance rating) hides the lapse until the site rating falls below it (Oseberg: never at 0-20 °C ambient). Ask whether the cap is an ISO rating (derate it with site factor) or a hard limit, and report both |

| Efficiency "improves" on a hot day at fixed MW | The part-load polynomial uses load = P / available power; at the same MW a hot-day turbine is at higher load fraction, so its heat rate can drop. Compare at a fixed load fraction (0.8 * getAvailablePowerAtAmbient(T)) when judging ambient effects |

| Exhaust/WHRU duty independent of load and ambient | WHRU = m·cp·(T_exh − T_stack)·eff with m ∝ (0.5 + 0.5 load) and T_exh = full-load(T) + part-load shape; a generator in hot standby at 30 % load gives a small fraction of the nameplate WHRU duty, so "kept as backup" HKs give no heat unless run (power-from-shore plants) |