Hydrogen Production with NeqSim
Guide for modeling hydrogen production routes — steam methane reforming (SMR),
autothermal reforming (ATR), partial oxidation (POX), PSA purification (blue
H2), and water electrolysis (green/pink H2). Companion to
neqsim-ccs-hydrogen (transport/storage/blending) and neqsim-reaction-engineering
(reformer kinetics).
When to Use This Skill
- SMR fired reformer, ATR, and POX plant flowsheets with WGS + PSA
- Oxygen-to-carbon and steam-to-carbon envelope screening
- Reformer furnace heat-balance and tube-wall checks
- POX/ATR quench, refractory, soot-risk, and H2/CO screening
- PSA bed sizing and purity/recovery analysis
- Electrolyzer technology selection (PEM vs Alkaline vs SOEC vs AEM)
- Stack voltage modeling from current density (I-V curves)
- Specific energy consumption (kWh/kg H₂)
- Hydrogen plant CAPEX estimation
- Cryogenic para/ortho H₂ conversion screening
- Catalyst activity decay for SMR/WGS/ammonia cracking studies
- Blue vs green H₂ techno-economic comparison
Applicable Standards
| Standard | Scope |
|---|---|
| ISO 14687 | Hydrogen fuel quality (PEM-FC grade ≥ 99.97% H₂) |
| ISO 22734 | Industrial water electrolyzers — safety |
| IEC 62282 | Fuel cell technologies (electrochemistry conventions) |
| API 941 | Steels for H₂ service (Nelson curves) |
| ASME B31.12 | Hydrogen piping and pipelines |
| EIGA Doc 121 | H₂ generator design (SMR/electrolysis) |
| IRENA 2022 | Green H₂ cost benchmarks |
| IEA Global H₂ Review 2023 | Capacity factors, USD/kW benchmarks |
Core Classes (Thermochemical route templates)
| Class | Package | Purpose |
|---|---|---|
| CatalyticTubeReformer | neqsim.process.equipment.reactor | Tube-side SMR equilibrium model with duty, pressure-drop, tube-wall, heat-flux, and catalyst-activity screening |
| ReformerFurnace | neqsim.process.equipment.reactor | Fired SMR furnace coupling FurnaceBurner combustion heat to reformer-tube duty |
| SyngasBurnerZone | neqsim.process.equipment.reactor | Oxygen-blown ATR/POX burner-zone model with O2/C envelope and flame-temperature screening |
| AutothermalReformer | neqsim.process.equipment.reactor | ATR template with O2/C and S/C controls, burner zone, catalytic equilibrium zone, and soot-risk metric |
| PartialOxidationReactor | neqsim.process.equipment.reactor | POX template with O2/C control, refractory warning, fast quench, and H2/CO output |
| QuenchSection | neqsim.process.equipment.reactor | Rapid syngas cooling model with heat-removed and quench-severity outputs |
| WaterGasShiftReactor | neqsim.process.equipment.reactor | HT/LT WGS equilibrium wrapper with CO conversion, H2 gain, CO2 formation, duty, and WGS ratio reporting |
| ComponentCaptureUnit | neqsim.process.equipment.splitter | Selective component-capture placeholder for CO2 capture, H2 drying, and other screening separations |
| SMRHydrogenPlantBuilder | neqsim.process.hydrogen | Screening plant builder for methane/steam feed, fired reformer, and optional PSA |
| ATRHydrogenPlantBuilder | neqsim.process.hydrogen | Screening plant builder for methane/steam/oxygen feed, ATR, and optional PSA |
| POXHydrogenPlantBuilder | neqsim.process.hydrogen | Screening plant builder for POX syngas or hydrogen studies with optional PSA |
| BlueHydrogenPlantBuilder | neqsim.process.hydrogen | Full screening chain for SMR + HT/LT WGS + CO2 capture/compression + PSA + H2 drying/compression + carbon intensity |
Thermochemical maturity map
| Technology | Implemented NeqSim pattern | Maturity | Remaining high-fidelity scope |
|---|---|---:|---|
| Steam methane reforming (SMR) | ReformerFurnace + CatalyticTubeReformer + FurnaceBurner | 4/5 | Detailed radiant-box view factors, burner CFD, tube metallurgy/vendor rating |
| Autothermal reforming (ATR) | AutothermalReformer with SyngasBurnerZone + catalytic GibbsReactor | 4/5 | Burner aerodynamics, oxygen-mixing CFD, rate-based catalyst bed calibration |
| Partial oxidation (POX) | PartialOxidationReactor + SyngasBurnerZone + QuenchSection | 3/5 | Fast-quench kinetics, refractory thermal model, soot/coke kinetics |
Core Classes (Horizon 1)
| Class | Package | Purpose |
|---|---|---|
| PressureSwingAdsorptionBed | neqsim.process.equipment.adsorber | H₂-tuned single PSA bed (AC or Zeolite 13X) |
| AdsorptionCycleController | neqsim.process.equipment.adsorber | Multi-bed Skarstrom-style cycling (pre-existing) |
| Electrolyzer | neqsim.process.equipment.electrolyzer | Stack model with technology defaults and Faradaic efficiency |
| ElectrolyzerTechnology | same | Enum PEM / ALKALINE / SOEC / AEM with default voltage, current density, T, P, η_F |
| ElectrolyzerIVCharacteristic | same | Tafel + ohmic voltage model; tech-specific defaults |
| ElectrolyzerCostEstimate | neqsim.process.costestimation.electrolyzer | Specific-CAPEX × scale-factor × CEPCI |
Core Classes (Horizon 1.5)
| Class | Package | Purpose |
|---|---|---|
| PSACascade | neqsim.process.equipment.adsorber | Multi-bed Skarstrom cascade (2/4/6/8/10/12 beds) with recovery uplift from pressure equalisation |
| PSACostEstimate | neqsim.process.costestimation.adsorber | Per-bed vessel + valve skid + sorbent inventory × CEPCI |
Core Classes (Horizon 3 foundations)
| Class | Package | Purpose |
|---|---|---|
| ParaOrthoH2Correction | neqsim.thermo.util.hydrogen | Equilibrium para fraction, normal-to-equilibrium heat release, Cp correction, thermal-conductivity factor, conversion time |
| CatalystDeactivationKinetics | neqsim.process.equipment.reactor | First-order activity decay for sulfur/chloride poisoning, coking, and thermal sintering |
Recipe 0 — SMR / ATR / POX route builders
Use the route builders when a task needs a runnable screening flowsheet quickly.
They create feeds with correct trace syngas products, set SRK + classic mixing,
wire the reactor model, and optionally add a PSA cascade.
ProcessSystem smr = new SMRHydrogenPlantBuilder().setName("SMR screening")
.setMethaneFeedMolePerSec(100.0)
.setSteamToCarbonRatio(3.0)
.setIncludePsa(true)
.build();
smr.run();
ReformerFurnace furnace =
(ReformerFurnace) smr.getUnit("SMR screening reformer furnace");
double dutyKW = furnace.getTubeHeatDemandKW();
double heatBalance = furnace.getHeatBalanceRatio();
ProcessSystem atr = new ATRHydrogenPlantBuilder().setName("ATR screening")
.setMethaneFeedMolePerSec(100.0)
.setSteamToCarbonRatio(1.5)
.setOxygenToCarbonRatio(0.60)
.setIncludePsa(true)
.build();
atr.run();
ProcessSystem pox = new POXHydrogenPlantBuilder().setName("POX screening")
.setMethaneFeedMolePerSec(100.0)
.setOxygenToCarbonRatio(0.55)
.setSteamToCarbonRatio(0.20)
.build();
pox.run();
Key route outputs:
ReformerFurnace:getSyngasOutStream(),getFlueGasOutStream(),
getTubeHeatDemandKW(), getAvailableRadiantHeatKW(), getHeatBalanceRatio().
CatalyticTubeReformer:getMethaneConversion(),getHeatDuty("kW"),
getTubeWallTemperature(), isTubeWallTemperatureAcceptable().
AutothermalReformer:getOxygenToCarbonRatio(),getSteamToCarbonRatio(),
getMethaneConversion(), getSootRiskIndex(), getBurnerZone().
PartialOxidationReactor:getHydrogenToCarbonMonoxideRatio(),
getRefractoryWarning(), getQuenchSection(), getSootRiskIndex().
- Every new route unit exposes
getResults()andtoJson()for agent reports.
Recipe 1 — Blue H₂ full chain (SMR + WGS + capture + PSA + export)
BlueHydrogenPlantBuilder builder = new BlueHydrogenPlantBuilder()
.setName("Blue H2 screening")
.setMethaneFeedMolePerSec(100.0)
.setSteamToCarbonRatio(3.0)
.setCo2CaptureFraction(0.90)
.setCo2ExportPressure(110.0)
.setH2ExportPressure(100.0)
.setIncludePsa(true);
ProcessSystem process = builder.build();
process.run();
double h2KgPerHr = builder.getHydrogenProductMassFlowKgPerHour();
double capturedCo2KgPerHr = builder.getCapturedCo2MassFlowKgPerHour();
double residualIntensity = builder.getCarbonIntensityKgCO2PerKgH2();
double grossIntensity = builder.getGrossCarbonIntensityKgCO2PerKgH2();
String resultsJson = builder.toJson();
Notes
- The default sequence is SMR furnace → HT WGS → LT WGS → cooler/KO → CO2
capture → CO2 compressor → PSA → H2 dryer → H2 compressor.
WaterGasShiftReactortreats methane, nitrogen, and oxygen as inert and
reports CO conversion, H2 gain, CO2 formation, heat duty, and WGS ratio.
ComponentCaptureUnitis a screening placeholder. Use it for CO2 capture and
H2 drying when detailed amine, membrane, or molecular-sieve packages are not
yet available.
- Carbon-intensity reporting counts residual direct carbon as CO2 equivalent and
reports both residual and gross intensity per kg H2 product.
Recipe 1b — PSA-only purification block
PressureSwingAdsorptionBed psa = new PressureSwingAdsorptionBed("PSA", koVap);
psa.setSorbent(PressureSwingAdsorptionBed.SorbentType.ACTIVATED_CARBON);
psa.setRecoveryTarget(0.88);
psa.run();
double purityH2 = psa.getH2Purity();
double recoveryH2 = psa.getH2Recovery();
double[] tailComp = psa.getTailGasComposition();
Use the standalone PSA block when a shifted syngas stream is already available
from a custom flowsheet.
Recipe 2 — Green H₂ Electrolyzer
// Water feed to the stack — molar flow sets the H₂ production target.
SystemInterface water = new Fluid().create("water");
Stream feed = new Stream("water", water);
feed.setFlowRate(100.0, "mole/sec"); // ~10 kg H₂/hr at η_F = 1
feed.setTemperature(298.15, "K");
feed.setPressure(1.0, "bara");
feed.run();
Electrolyzer el = new Electrolyzer("PEM stack", feed);
el.setTechnology(ElectrolyzerTechnology.PEM); // applies V/j/η_F; retains inlet T/P
el.setIVCharacteristic(new ElectrolyzerIVCharacteristic(ElectrolyzerTechnology.PEM));
el.run();
double power_kW = el.getStackPower();
double sec = el.getSpecificEnergyConsumption_kWh_per_kg_H2();
double V_cell = el.getCellVoltage(); // recomputed from I-V at run time
Technology selector
| Tech | Fixed V_cell | j (A/cm²) | Reference T (°C) | Reference P (bara) | Nominal η_F | Fixed-voltage stack SEC (kWh/kg) |
|---|---|---|---|---|---|---|
| PEM | 1.80 | 2.0 | 80 | 30 | 0.65 (unqualified legacy) | 73.63 |
| ALKALINE | 1.85 | 0.4 | 80 | 7 | 0.95850234 (screening extrapolation) | 51.32 |
| SOEC | 1.30 | 1.0 | 800 | 1 | 0.85 (unqualified legacy) | 40.67 (electricity only) |
| AEM | 1.85 | 0.8 | 60 | 10 | 0.60 (unqualified legacy) | 81.98 |
Distinguish current efficiency from LHV/HHV energy efficiency. Treat the table as
implemented screening inputs and arithmetic, not measured technology performance.
For alkaline, use Ulleberg (2003), Eq. (9), Table 3 PHOEBUS parameters
(f1=250 (mA/cm²)², f2=0.96, 80 °C, reported 7 bar), DOI
10.1016/S0360-3199(02)00033-2. Evaluating at 400 mA/cm² extrapolates beyond
Fig. 6; it has no established uncertainty interval or off-design qualification.
Supply measured efficiency after setTechnology; that call overwrites prior
voltage/efficiency settings and retains the inlet T/P. Set feed T/P separately.
Consult the equipment guide
and open #4682 before using legacy defaults in a benchmark. At alkaline nominal
j/T, the existing I–V model gives 1.7064354 V and 47.33637 kWh/kg instead of the
fixed-voltage result. Do not infer a validated SEC from either model or use SOEC
heat substitution as evidence of current efficiency.
I-V curve internals
getCellVoltage(j, T_K) = E_rev(T) + A · log10(j / j0) + R · j
E_rev(T) = 1.229 V + (-0.85 mV/K) · (T - 298.15)(Larminie & Dicks)- Tafel slope
A, exchange currentj0, ASRRare technology defaults - Below
j0the model returnsE_rev(no spurious negative overpotential)
Recipe 4 — Multi-bed PSA cascade
PSACascade cascade = new PSACascade("H2-PSA", koVap);
cascade.setConfiguration(PSACascade.CascadeConfiguration.BEDS_6); // 6 beds, 2 PEQ
cascade.setSorbent(PressureSwingAdsorptionBed.SorbentType.ACTIVATED_CARBON);
cascade.setPerBedRecoveryTarget(0.82); // single-bed equilibrium recovery
cascade.setCycleTime(300.0); // seconds per bed cycle
cascade.run();
double purity = cascade.getH2Purity(); // > 99.9 %
double recovery = cascade.getH2Recovery(); // single-bed + cascade uplift
Stream tail = cascade.getTailGasStream(); // for SMR fuel-gas balance
Cascade uplift table (pressure equalisation steps → recovery gain over a single bed):
| Configuration | Beds | Equalisations | Uplift |
|---|---|---|---|
| BEDS_2 | 2 | 0 | +0.00 |
| BEDS_4 | 4 | 1 | +0.05 |
| BEDS_6 | 6 | 2 | +0.08 |
| BEDS_8 | 8 | 3 | +0.10 |
| BEDS_10 | 10 | 4 | +0.11 |
| BEDS_12 | 12 | 5 | +0.12 |
Total cascade recovery is capped at 0.93 (industrial benchmark for H₂ PSA on shifted syngas).
Recipe 5 — PSA cascade CAPEX
PSACostEstimate cost = new PSACostEstimate(cascade); // derives N_beds, sorbent, mass
cost.calculateCostEstimate();
double usd = cost.getPurchasedEquipmentCost();
- Reference per-bed vessel cost: USD 250 000 at 2 m × 4 m TL-TL, scale exponent 0.6.
- Valve skid: USD 60 000 per bed (manifold + actuators + cycle controller).
- Sorbent inventory: USD 4/kg AC or USD 10/kg Zeolite 13X.
- Balance-of-plant strip (
setIncludeBalanceOfPlant(false)) removes ~25 % for vessel-only quotes. - CEPCI 2024 = 800 reference; multiply by
CostEstimationCalculator.getCurrentCepci()/800.
Recipe 6 — Para/ortho H₂ correction for cryogenic screening
double para20K = ParaOrthoH2Correction.getEquilibriumParaFraction(20.0);
double heatJPerKg = ParaOrthoH2Correction.getNormalToEquilibriumHeatJPerKg(20.0);
double cpCorrection = ParaOrthoH2Correction.getCpCorrectionJPerKgK(40.0);
double conductivityFactor = ParaOrthoH2Correction.getThermalConductivityCorrectionFactor(20.0);
double tauSeconds = ParaOrthoH2Correction.estimateEquilibrationTimeSeconds(
77.0, ParaOrthoH2Correction.ConversionCatalyst.HYDROUS_FERRIC_OXIDE);
- Normal hydrogen is 25% para; equilibrium hydrogen approaches >99% para near 20 K.
getNormalToEquilibriumHeatJPerKg(T)returns positive exothermic heat release.getCpCorrectionJPerKgK(T)is equilibrium minus frozen-normal rotational heat capacity.- Thermal-conductivity correction factors are bounded screening multipliers for normal-H₂ correlations.
Recipe 7 — Catalyst deactivation activity factor
CatalystBed bed = new CatalystBed();
CatalystDeactivationKinetics kinetics = new CatalystDeactivationKinetics(
CatalystDeactivationKinetics.CatalystFamily.NICKEL_REFORMING)
.setTemperature(973.15)
.setSulfurPpmv(0.05)
.setCarbonPotential(0.5)
.setSteamToCarbonRatio(2.5)
.setOperationHours(8000.0);
double activity = kinetics.applyTo(bed);
double timeTo80 = kinetics.estimateTimeToActivity(0.80);
String mechanism = kinetics.getDominantMechanism();
- Families:
NICKEL_REFORMING,IRON_CHROMIUM_HT_SHIFT,COPPER_ZINC_LT_SHIFT,
RUTHENIUM_AMMONIA_CRACKING.
- Mechanisms: sulfur poisoning, chloride poisoning, coking, and thermal sintering.
- Use vendor/lab/historian coefficients before detailed run-length guarantees.
Recipe 3 — Electrolyzer CAPEX
el.initMechanicalDesign();
ElectrolyzerMechanicalDesign mech =
(ElectrolyzerMechanicalDesign) el.getMechanicalDesign();
mech.calcDesign(); // populates totalPowerKW
ElectrolyzerCostEstimate cost = new ElectrolyzerCostEstimate(mech);
cost.setTechnology("PEM");
double usd = cost.getPurchasedEquipmentCost();
- Specific CAPEX (2024 USD/kW, CEPCI 800): PEM 1250, Alkaline 800, SOEC 2500, AEM 1500.
- Scale exponent 0.85 vs reference 1 MW.
setIncludeBalanceOfPlant(false)strips ~35% for stack-only quotes.- Numbers are AACE Class 4–5 — do not use for FID without vendor budget quotes.
Color taxonomy and route map
| Color | Route | NeqSim primitives |
|---|---|---|
| Grey | SMR no CCS | GibbsReactor + WGS + PressureSwingAdsorptionBed |
| Blue | SMR/ATR + CCS | Add CO₂ capture (amine/MEA) → see neqsim-ccs-hydrogen |
| Green | Renewable electrolysis | Electrolyzer with PEM/Alkaline + renewable power feed |
| Pink | Nuclear electrolysis | Same Electrolyzer, accounting differs |
| Turquoise | Methane pyrolysis | Not yet — Horizon 2 |
Common pitfalls
- Thermochemical scope:
ReformerFurnace,AutothermalReformer, and
PartialOxidationReactor are route-screening models, not vendor reactor
designs. Use them for heat balance, O2/C and S/C envelopes, soot/refractory
warnings, and handoff to WGS/PSA/CO2 capture. Use vendor data or detailed CFD
for radiant-box, burner, and tube-rating guarantees.
- Trace products: Gibbs syngas models need product components present in the
feed. The route builders and HydrogenProductionUtils.ensureSyngasComponents()
add hydrogen, CO, and CO2 at trace levels.
- ATR/POX controls: ratio controls rebuild the controlled inlet clone from
methane moles before running. Disable ratio control only when a measured or
externally generated feed composition must be preserved exactly.
PressureSwingAdsorptionBed.run()mass balance: product purity is computed
from feedH2 × recovery ÷ remaining light gases. Always set the recovery target
before run(); default is 0.85.
- Electrolyzer voltage: when no
ElectrolyzerTechnologyis set, the legacy
fixed-voltage path (V = 1.23 V, η_F = 1.0) stays active for backward compatibility.
- Specific energy:
getSpecificEnergyConsumption_kWh_per_kg_H2()is
stackPower_kW / (n_H2 · MW_H2 · 3600). Below ~33 kWh/kg means the model is
predicting >100% LHV efficiency — recheck inputs.
- Cost estimate: requires
mech.calcDesign()before construction so
totalPowerKW > 0.
- Para/ortho scope:
ParaOrthoH2Correctionis a screening correction, not a
complete liquefaction process model.
- Catalyst life scope:
CatalystDeactivationKineticsdefault coefficients are
order-of-magnitude values. Tune them to vendor or historian data for plant-specific forecasts.
Tests for verification
| Test | Coverage |
|---|---|
| PressureSwingAdsorptionBedTest | Defaults, recovery cap, mass balance, composition, sorbent switch |
| PSACascadeTest | Cascade uplift, bed-count monotonicity, 0.93 cap, tail-gas mass balance |
| PSACostEstimateTest | Bed-count linearity, sorbent ordering, BoP toggle, order of magnitude |
| ParaOrthoH2CorrectionTest | Para equilibrium limits, conversion heat, Cp correction, conductivity factor, catalyst time ranking |
| CatalystDeactivationKineticsTest | Catalyst-family sensitivity, coking, sintering, dominant mechanism, CatalystBed activity update |
| ElectrolyzerTechnologyTest | Per-tech default consistency |
| ElectrolyzerIVCharacteristicTest | E_rev vs T, Tafel monotonicity, technology ordering |
| ElectrolyzerTest | Backward compat + η_F + I-V + specific-energy band |
| ElectrolyzerCostEstimateTest | Per-tech ordering, BoP toggle, scale economy |
| HydrogenProductionReactorTest | SMR tube/furnace metrics, ATR ratio controls, POX quench/refractory metrics, equipment factory aliases |
| HydrogenPlantBuilderTest | Runnable SMR, ATR, POX, and blue-H2 plant builder templates |
Deferred (Horizon 2/3)
- Rate-based amine absorber for CO₂ capture upstream of blue H₂
- Full cryogenic H₂ liquefaction train with expanders and heat integration
- High-fidelity reformer radiant-box view factors, burner CFD, and vendor tube-rating integration
- Ammonia cracking kinetics for H₂ delivery from NH₃
- Hydrogen LCA per production step
- LOHC and photo-electrolysis