Neqsim heat integration

From equinor/neqsim · View interactive version

Neqsim heat integration is an AI agent skill from the GitHub repository equinor/neqsim. Pinch analysis and heat integration — composite curves, ΔTmin selection, MER targeting, grand composite, HEN synthesis, retrofit. USE WHEN: a task involves reducing utility cost, evaluating heat recovery, sizing utility duties, or comparing process alternatives on energy efficiency. Anchors on neqsi

How to use this skill

Skill file

NeqSim Heat Integration Skill

Linnhoff-method pinch analysis to determine minimum hot/cold utility duties,

the pinch temperature, composite & grand-composite curves, and to evaluate

heat-exchanger network (HEN) opportunities.

When to Use

Standard reference: B. Linnhoff & E. Hindmarsh (1983), Chem. Eng. Sci.;

operational guidance from Smith — Chemical Process Design and Integration (2nd ed.).

Core Concept

Hot streams (need cooling)  ──┐
                              ├── shifted by ΔTmin/2 → temperature intervals → cascade → MER
Cold streams (need heating) ──┘

The pinch divides the system in two:

Three golden rules — never violate any of them:

  1. No external heating below the pinch
  2. No external cooling above the pinch
  3. No heat transfer across the pinch

Pattern 1 — Streams Defined Manually

import neqsim.process.equipment.heatexchanger.heatintegration.PinchAnalysis;

PinchAnalysis pinch = new PinchAnalysis(10.0);   // ΔTmin in °C
// addHotStream(name, supplyT_C, targetT_C, mCp_kW_per_K)
pinch.addHotStream("H1 — reactor effluent",  180.0,  80.0, 30.0);
pinch.addHotStream("H2 — flash gas",         150.0,  50.0, 15.0);
pinch.addColdStream("C1 — feed preheat",      30.0, 140.0, 20.0);
pinch.addColdStream("C2 — reboiler feed",     60.0, 120.0, 25.0);
pinch.run();

double Qh   = pinch.getMinimumHeatingUtility();    // kW
double Qc   = pinch.getMinimumCoolingUtility();    // kW
double Tpinch = pinch.getPinchTemperatureC();

Pattern 2 — Auto-Extract from a ProcessSystem

PinchAnalysis pinch = PinchAnalysis.fromProcessSystem(process, 10.0);
pinch.run();

This walks every Heater, Cooler, and HeatExchanger and registers their duties as streams.

Pattern 3 — Choosing ΔTmin

| Service | Typical ΔTmin |

| -------------------------------- | -------------- |

| Gas–gas refinery | 15–25 °C |

| Gas–liquid | 8–15 °C |

| Liquid–liquid | 5–10 °C |

| Cryogenic | 1–3 °C |

| Steam reboiler / cooling water | 8–10 °C |

Trade-off: lower ΔTmin → less utility (good OPEX) but bigger HX area (worse CAPEX).

Optimum is found from supertargeting — sweep ΔTmin and plot total-annual-cost.

Pattern 4 — Composite Curves for Visualization

// (after pinch.run())
double[] Th  = pinch.getHotCompositeT();
double[] Qh_ = pinch.getHotCompositeQ();
double[] Tc  = pinch.getColdCompositeT();
double[] Qc_ = pinch.getColdCompositeQ();
// Plot T vs Q → composite curves; the overlap = recoverable, the tails = utility

Plot the grand composite curve (getGrandCompositeQ/T()) to choose utility levels (HP/MP/LP steam, CW, refrigeration).

Pattern 5 — Retrofit Diagnostics

double existingUtility = sumExistingHotUtilities(process);   // user supplies
double saving = existingUtility - pinch.getMinimumHeatingUtility();
double saving_pct = 100.0 * saving / existingUtility;

Identify cross-pinch transfer with stream-level diagnostics (each violation costs double).

Common Mistakes

| Mistake | Fix |

| ------------------------------------------------------- | ------------------------------------------------------------------------- |

| Using mass flow instead of mCp | mCp = ṁ × cp (kW/K); for phase-change, treat as multiple linear segments |

| Single ΔTmin for both gas–gas and liquid–liquid | Use stream-individual film coefficients or split into zones |

| Counting reboiler/condenser duties as process streams | They are utilities — exclude or model as utility curves above pinch |

| Ignoring soft constraints (forbidden matches) | Note them in the report; pinch gives the target, HEN respects constraints |

| Cross-pinch transfer in MER design | Re-route hot stream to above-pinch cold stream; never quench across pinch |

| Reporting only utility numbers without ΔTmin | Always state ΔTmin assumption; results scale strongly with it |

Validation Checklist

Related Skills