Flow Assurance Analysis with NeqSim
Consolidated guide for all flow assurance threats — hydrate, wax, asphaltene, corrosion,
hydraulics, water/liquid hammer screening, slugging, and thermal management — with
NeqSim code patterns.
Use the runPipeline analysis wellToTopsideSlugControl for the published
well-to-topside anti-slug replay. It reuses the canonical choke, two-fluid pipe,
three-phase separator and controller APIs and returns both control modes with
time series. Treat it as numerical reference evidence, not field validation.
For the public Tengesdal severe-slugging gate on the unsplit route, inspect
TwoFluidMassBalanceReport.getRejectedAttempts() and getModelEvaluations() after every accepted
observation interval. Use complete cycles from the final 300 s: require at least two pressure and
liquid-production cycles, stable cycle amplitude/period, repeatable pressure/liquid phase lock and
the unchanged experimental pressure-amplitude, inlet-pressure-period, hold-up, inventory and
conservation gates. Run 16 cells / 0.1 s, 16 / 0.05 s and 24 / 0.05 s before checking
refinement. The current matrix reaches 600 s but has zero complete settled pressure and liquid cycles
on every discretization; the 24-cell run also records two rejected attempts. Treat the experimental
metrics as unresolved, not passed by a startup extremum or enforced sign. Conservative moving
slug/film geometry is accepted transactionally by the unsplit route and has closed-pipe
four/eight-cell and one/two-step conservation checks. Accepted tracked cells can also use the
reconstructed body/film friction owner while untracked cells retain ordinary friction; the 0.1 s
16/24-cell startup matrix checks rollback, passive impulse, mass closure and time-step refinement.
The full five-second publication matrix with tracking enabled and the experimental cycle gates
remain open; keep the gate opt-in until all of them pass.
A complete study report with pipeline drawings (route, profiles, hydrate margin, threat matrix,
validation) is produced by
neqsim flow-assurance-report— see the
neqsim-flow-assurance-study-reportskill. This skill stays the calculation reference.
A whole subsea SURF network (templates, injection, risers, umbilical, concept comparison) is
generated, solved and documented by
neqsim surf-study— see theneqsim-surf-design-studyskill.
When to Use This Skill
- Hydrate formation temperature/pressure prediction
- Hydrate inhibitor dosing (MEG, methanol, ethanol)
- Wax appearance temperature (WAT) and wax deposition risk
- Asphaltene stability screening (de Boer, CII)
- CO2 and H2S corrosion rate estimation
- Elemental sulfur (S8) deposition risk at pressure/temperature letdown (compressor inlets, control/letdown valves, dry-gas seals, filters)
- Pipeline pressure drop and temperature profile
- DNV-RP-F109 vertical and lateral on-bottom stability screening
- Water hammer/liquid hammer screening for fast valve closure, pump trip, or check-valve slam
- Multiphase flow pattern prediction (slug, annular, stratified)
- Thermal insulation sizing for subsea pipelines
- Arrival temperature and cooldown calculations
(for TwoFluidPipe no-touch times use calculateColdestSectionHydrateCooldownTime() after run();
calculateHydrateCooldownTime() starts from the inlet temperature and overstates the time for the riser base)
Applicable Standards
| Domain | Standards | Key Requirements |
|--------|-----------|-----------------|
| Pipeline design | DNV-ST-F101, DNV-RP-F104 for CO2, NORSOK L-001, ASME B31.4/B31.8 | Structural design plus composition-specific CO2 phase/hydraulic and lifecycle basis |
| Corrosion | NORSOK M-001, DNV-RP-F112, ISO 21457 | Material selection, CO2/H2S corrosion rates |
| On-bottom stability | DNV-RP-F109 | Vertical stability, absolute lateral stability, displacement acceptance |
| Free spans | DNV-RP-F105 | Free-span response and fatigue assessment |
| Global buckling and pipe-soil interaction | DNV-RP-F110, DNV-RP-F114 | Caller-controlled external response and demand-resistance screening |
| Subsea systems | NORSOK U-001 | Subsea production-system requirements |
| Hydrate management | DNV-RP-F116 | Hydrate prevention and remediation |
| GRP piping | ISO 14692 | Non-metallic pipe design |
| Pipeline integrity | DNV-RP-F101, DNV-RP-F116, API 1160 | Inspected metal-loss remaining strength and integrity management |
For fast acoustic transients, also load neqsim-water-hammer. Use
WaterHammerStudy or MCP runWaterHammer with STID route geometry, tagreader
event windows, and valve/pump event schedules; use this flow-assurance skill for
the broader operating-envelope and mitigation context.
For on-bottom stability, load neqsim-subsea-and-wells and use the typed
DnvRpF109OnBottomStabilityKernel. It provides a transparent absolute-static
screen and checks externally calculated response displacements. It does not
contain generalized design tables, produce dynamic response, qualify environmental
or soil models, or claim DNV conformity. A pass still requires independent review.
This skill quantifies the threat (hydrate curve, WAT, SI, corrosion rate). For the
chemical answer — which product, minimum effective dose, cocktail compatibility, H2S/O2
scavenger sizing, demulsifier vs oil-in-water spec, and chemical root-cause of a deposit —
load neqsim-production-chemistry (neqsim.process.chemistry) and feed it the numbers
computed here.
For local dry hydrocarbon gas/oil interface investigations, the existing film boundary
has a default-off setCoupledMassHeatTransferEnabled(true) numerical option. Read
docs/fluidmechanics/InterphaseHeatMassTransfer.md for its residual gates and limited
positive-composition/finite-transport range. It is not connected to the transient
TwoFluidPipe source. Zero liquid Reynolds number currently gives an unsupported
stratified transfer coefficient and rejects; never interpret the old unit-matrix
fallback as stationary-pool evaporation. Keep #4674 physical boundary/full-cycle and
#4675 heat/area/diffusion qualification separate from numerical convergence.
1. Hydrate Analysis
EOS Selection for Hydrate Calculations
| Aqueous phase | NeqSim Class | Mixing Rule |
|---------------|-------------|-------------|
| Pure water / fresh water | SystemSrkCPAstatoil | 10 |
| Water + MEG / methanol / ethanol | SystemSrkCPAstatoil | 10 |
| Salt brine / formation water (NaCl, CaCl2, ...) | SystemElectrolyteCPAstatoil | 10 |
| Pitzer salt-brine water activity | SystemPitzer | "classic" |
All SRK-CPA solver variants (SystemSrkCPAstatoil, ...FullyImplicit, ...Reduced, ...Broyden...,
...Anderson...) and all SRK electrolyte-CPA systems use the same CPA hydrate cavity model
(ComponentHydrateGF), so they give the same hydrate temperature; pick the solver for speed. Before
21 Nov 2026 the variants silently used the PVTsim parameters (up to 0.44 K different). PR-CPA and UMR-CPA still
use PVTsim parameters. Check with ((PhaseHydrate) fluid.getPhases()[4]).getHydrateModel().
When no ions are present, prefer SystemSrkCPAstatoil over SystemElectrolyteCPAstatoil: same hydrate
temperature, 5–10× faster flash (e-CPA hydrate point 1–3 s, measured 21 Nov 2026).
SystemPitzer handles MEG (+ NaCl) through a fitted dataset (MEG ≤ 17.6 mol/kg). With N2 present the Pitzer
hydrate search cannot go below 278.12 K, so for MEG-inhibited low-temperature cases use e-CPA.
CPA or a consistent activity-based aqueous model is needed for water–hydrocarbon hydrate modeling.
**When dissolved salts / electrolytes are present, use SystemElectrolyteCPAstatoil or a
parameterized SystemPitzer** so the salt
thermodynamic (hydrate-suppression) effect is captured — plain
SystemSrkCPAstatoil ignores ion activity and underestimates subcooling margin.
For Pitzer hydrate onset, load neqsim-electrolyte-systems and read
docs/thermo/pitzer_hydrate_equilibrium.md. Accept its hand-off of salt mole basis, dataset,
explicit CO2-chloride zeta values (and K-Mg theta when both ions are present), pressure grid and operating temperature. Use the standard
temperature/pressure/curve operations; the Pitzer route checks the fugacity residual and throws
on failed points. Preserve the aqueous reference-state convention and guest Henry limits.
Do not label onset calculations as hydrate amounts, kinetics or validated complete drilling-mud predictions.
Carry forward the experimental assessment separately from convergence: the mixed-chloride high-pressure cases
include errors exceeding 1 K. Do not generalize the NaCl benchmark to all salts, concentrations or pressures.
Hydrate Formation Temperature
// CPA EOS required for accurate water-hydrocarbon modeling
SystemInterface fluid = new SystemSrkCPAstatoil(273.15 + 10, 100.0);
fluid.addComponent("methane", 0.80);
fluid.addComponent("ethane", 0.05);
fluid.addComponent("propane", 0.03);
fluid.addComponent("CO2", 0.02);
fluid.addComponent("water", 0.10);
fluid.setMixingRule(10); // CPA mixing rule
fluid.setMultiPhaseCheck(true);
fluid.setHydrateCheck(true);
ThermodynamicOperations ops = new ThermodynamicOperations(fluid);
ops.hydrateFormationTemperature();
double hydrateT_C = fluid.getTemperature() - 273.15;
Call setHydrateCheck(true). Since 21 Nov 2026 hydrateFormationTemperature() and
hydrateFormationPressure() add the hydrate phase themselves if it is missing, but older releases fail
(no hydrate phase) and any wrapper that swallows the exception reports NaN. The fluid must
contain water. HydrateRiskMapper (and MCP runFlowAssurance hydrateRiskMap) now sets the
flag itself and returns RiskLevel.UNKNOWN / RESULT_NOT_AVAILABLE with failureReasons when
no equilibrium temperature exists — never treat an unavailable hydrate temperature as safe.
Hydrate Equilibrium Curve (Multiple Pressures)
// Calculate hydrate T at several pressures for the full curve
double[] pressures = {20, 40, 60, 80, 100, 120, 150, 200};
double[] hydrateTemps = new double[pressures.length];
for (int i = 0; i < pressures.length; i++) {
SystemInterface testFluid = fluid.clone();
testFluid.setPressure(pressures[i]);
ThermodynamicOperations testOps = new ThermodynamicOperations(testFluid);
testOps.hydrateFormationTemperature();
hydrateTemps[i] = testFluid.getTemperature() - 273.15;
}
Host inhibitor-availability gate (check BEFORE selecting an inhibitor strategy)
A MEG (or methanol) dose that NeqSim calculates is only a strategy if the host can deliver it. Before choosing
continuous MEG for a tie-back or export line, establish from host drawings, equipment lists and the operator:
- MEG regeneration/reclamation plant at the host or on the receiving route (lean MEG capacity, rich MEG handling,
water load, salt/solids handling). Without one, MEG is single-use and continuous injection is not a strategy.
- Existing continuous MEG injection that the new line can share (storage, injection pumps, a MEG line or umbilical
service line to the template, spare capacity in m3/h and storage days).
- Batch (shut-in/restart) injection capability: tank volume, pump, supply route (umbilical chemical line, riser-side
injection point), and where used MEG goes afterwards.
If (1) and (2) are not confirmed, record a data gap and treat continuous MEG as not available; do not size a loop on
it. If MEG is selected anyway (continuous, or batch at shut-in), evaluate the host topside for it: utilisation of the
existing capacity (regeneration, storage, pumps, MEG line/umbilical service line) against the new demand, or the
installation required when nothing exists (regeneration/reclamation package sized on lean MEG rate, rich MEG and water
load, storage days, injection pumps, heater/reboiler duty and power, deck space, weight, utilities, tie-in points, rough
cost class), and show it on the tie-in PFD/P&ID and in the host debottlenecking register. Screen the alternatives instead and report which host capability each one depends on: hydrate-free margin in flowing
operation (including the minimum rate that keeps arrival temperature above the hydrate temperature, only relevant when
free water is present), depressurisation to below the hydrate pressure at seabed temperature, displacement/flush with dead
oil or diesel before a planned shut-in, insulation/heat tracing and cooldown (no-touch) time, and batch MEG/methanol/LDHI at
shut-in and restart (volume from the water in place and the settle-out pressure). State the data needed to confirm each.
Hydrate Inhibitor Dosing (MEG)
// Add MEG to suppress hydrate formation temperature
SystemInterface inhibitedFluid = new SystemSrkCPAstatoil(273.15 + 4, 100.0);
inhibitedFluid.addComponent("methane", 0.80);
inhibitedFluid.addComponent("water", 0.15);
// 25 wt% MEG in the water + MEG phase: n_MEG = n_water * 18.015 * 0.25 / 0.75 / 62.07 = 0.0145 mol
// (0.05 mol MEG per 0.15 mol water would be 53 wt%: amounts are MOLES, never weight percentages)
inhibitedFluid.addComponent("MEG", 0.0145);
inhibitedFluid.setMixingRule(10);
inhibitedFluid.setMultiPhaseCheck(true);
inhibitedFluid.setHydrateCheck(true);
ThermodynamicOperations ops = new ThermodynamicOperations(inhibitedFluid);
ops.hydrateFormationTemperature();
double inhibitedHydrateT = inhibitedFluid.getTemperature() - 273.15;
// Compare with uninhibited to get subcooling margin
For the injection rate that delivers a required wt% in the water phase (including purity
and lean/rich MEG bookkeeping), use
neqsim.process.chemistry.hydrate.ThermodynamicHydrateInhibitorPerformance — see
neqsim-production-chemistry. Use the CPA curve above for the design concentration and the
chemistry model for the rate.
Salt-Inhibited Hydrate (Formation Water / Brine)
// Dissolved salts depress the hydrate temperature — use the electrolyte CPA model
SystemInterface brineGas = new SystemElectrolyteCPAstatoil(273.15 + 4, 100.0);
brineGas.addComponent("methane", 0.80);
brineGas.addComponent("water", 0.18);
brineGas.addComponent("Na+", 0.01); // dissociated NaCl
brineGas.addComponent("Cl-", 0.01);
brineGas.setMixingRule(10);
brineGas.setMultiPhaseCheck(true);
brineGas.setHydrateCheck(true);
ThermodynamicOperations ops = new ThermodynamicOperations(brineGas);
ops.hydrateFormationTemperature();
double brineHydrateT = brineGas.getTemperature() - 273.15;
// SystemSrkCPAstatoil would miss the salt suppression — always use electrolyte CPA with ions
MEG Concentration Sweep
// Find required MEG concentration for target subcooling
double[] megWtPct = {0, 10, 20, 30, 40, 50};
for (double wt : megWtPct) {
// wt % MEG is a MASS fraction of the water + MEG mixture: convert to moles (M_water 18.015, M_MEG 62.07 g/mol)
double waterMol = 0.20 * (1.0 - wt / 100.0) / 18.015;
double megMol = 0.20 * (wt / 100.0) / 62.07;
double waterFrac = waterMol / (waterMol + megMol) * 0.20;
double megFrac = megMol / (waterMol + megMol) * 0.20;
SystemInterface testFluid = new SystemSrkCPAstatoil(273.15, 100.0);
testFluid.addComponent("methane", 0.80);
testFluid.addComponent("water", waterFrac);
testFluid.addComponent("MEG", megFrac);
testFluid.setMixingRule(10);
testFluid.setHydrateCheck(true);
ThermodynamicOperations testOps = new ThermodynamicOperations(testFluid);
testOps.hydrateFormationTemperature();
// Record hydrate T vs MEG concentration
}
Sweep gotchas (found building an HPHT tie-back, Fogelberg VPbo task): hydrateFormationTemperature()
with a rich gas condensate (C7+ pseudo-components) plus water and MEG at 40 wt % MEG did not return
(CPA hydrate solver loop, no exception, no timeout). Run every MEG/pressure point of a sweep in a
watchdog thread or subprocess with a hard time limit and keep the sweep to at most 30 wt % MEG. If a
40-50 wt % row is still needed, a linear extrapolation (about -4.5 K per 10 wt % at 30-400 bara) is an
UNVALIDATED screening number: label it as extrapolated, never use it for a pass/fail margin, and do not
let the whole script hang for it. Write the intermediate JSON before the hydrate loop so a kill does not lose the
fluid and CVD results.
For flowline hydraulics with PipeBeggsAndBrills a trial inlet pressure that is too low throws
HydraulicDomainException: Non-positive pipeline pressure instead of returning a low outlet pressure:
catch it inside the chain function and return outlet 0 (infeasible). Letting it propagate out of a
bisection silently turns a whole row of the inlet-pressure table into NaN.
ThermodynamicOperations.hydrateFormationTemperature() is void: the answer is left in the fluid
temperature, so read fluid.getTemperature() - 273.15 after the call (float(ops.hydrateFormationTemperature())
fails with NoneType; found in the Mistral Nord VPbo task). A wellstream built with SystemSrkEos plus
setHydrateCheck(true) also under-predicts the hydrate temperature (methane benchmark about -8 K): rebuild
the composition in SystemSrkCPAstatoil (mixing rule 10) and benchmark methane at 43/76/140 bara against
5/10/15 C before using the numbers (CPA gives -0.03/+0.33/+0.58 K).
To benchmark PipeBeggsAndBrills against Darcy-Weisbach use a dry single-phase gas (pure methane, 60 C,
setHeatTransferCoefficient large): the deviation is then 0.2-0.4 %. A lean-gas condensate line cooled
to seabed temperature differs by 25-50 % because the liquid holdup is real, so that difference is not a defect.
Gas-condensate saturation pressure (Tyrihans cellar task): a bubble-point search on a lean gas-condensate fluid returns
a wrong value because the fluid has a dew point; take the saturation pressure of GOR above about 1500 Sm3/Sm3 fluids
from the CVD first step (dew point) and record it as a limitation. hydrateFormationTemperature() on a GOR 250 oil fluid
with 3 mol % water at 200 bara did not converge and left the temperature unchanged: check that the returned temperature
differs from the start temperature before reporting it and report None as a gap, not as a hydrate-free result.
HPHT wellstream hydrates (Erlend / Kristin study): the CPA hydrate solver also stalls (no exception) with the
C7+ TBP/plus pseudo-components at 50 bara and 1 mol % water, even without MEG. Rebuild the CPA mixture from the
light components only (C1-C6, N2, CO2, water, renormalised), as C7+ barely moves the hydrate temperature; a
Kristin-type gas (CGR 300 Sm3/MSm3) with 1 mol % water gave 17.2 / 21.2 / 26.6 / 31.9 C at 50 / 100 / 300 / 600 bara.
Do not iterate PipeBeggsAndBrills inlet pressure by a fixed point p_in += p_out_target - p_out: it stalls at high
pressure drop (unconverged tables looked like data). Use a secant solve, treat a HydraulicDomainException as outlet
pressure 0, store an ok flag and exclude ok == False rows when interpolating; beyond the last converged rate
extend the table with dp proportional to q^2 instead of the last slope.
MEG/Water Film Conditioned by Dry Gas (pipeline drying after glycol swabbing)
Question pattern: "what MEG:H2O ratio does a residual film reach under dry export gas, and why is
the gas above the dew-point spec?" Worked task: 2026-09-29_steady_state_megh2o_ratio_during_dry_gas_drying_of_a_meg.
- Direction: a 99 wt% MEG film is drier than the plateau (about 90 wt% at 6 C, 140 bara), so the
gas is the wetter side and the film absorbs water. It "dries" only if it starts wetter than the plateau.
- Equilibrium curve: two-phase
SystemSrkCPAstatoilTPflashes over an MEG sweep give gas water and MEG
content versus film composition (gas composition depends on the liquid composition, T and P only).
Report film composition on a gas-free basis, MEG/(MEG+water); dissolved CO2/CH4 is ~0.8 wt%.
MEG is not strictly non-volatile: about 5 ppm wt in the gas at 140 bara.
- Dew-point spec fixes only the water mole fraction y_in, not the pipe condition. Hand chain: water
fugacity continuity, a_w = y_in * phiV_w(T,P) * P / f0_w(T,P), with f0_w = IAPWS vapour pressure x
Poynting; a_w from the CPA liquid fugacity coefficient divided by the pure-water coefficient. Use binary
(gas-free) mole fractions when fitting ln gamma_w or the fit mis-predicts at high MEG.
- Plateau offset by mass balance: with a stationary film the gas leaves carrying water and MEG in the
film's own ratio, so (y_out - y_in)/y_in = r * y_MEG / y_in (about 1.7 %), independent of K_G at large NTU.
The film inlet zone is stripped of MEG first (a film-free zone grows at ~200 m/day in a 0.4 m, 60 kg/s example).
- Flash per time step is backward Euler: unconditionally stable, plateau independent of step size; an
explicit coding is stable only below 2 / (d y*_H2O / d r) kg gas per kg film MEG per step.
- Dew point is logarithmic (~6 % in water content per K at these conditions) and, for CPA, nearly
pressure independent at 70-140 bara: reading the same gas as a dew point at pipe pressure adds ~0.9 K.
- Basis traps: CPA liquid-water dew point is a supercooled-liquid reference below freezing;
ISO 18453 / GERG-water uses an ice reference below 273.16 K. These are different phase boundaries.
For GERG-water, use SystemGERGwaterEos, setMixingRule(8), and a
ThermodynamicOperations instance's waterDewPointTemperatureFlash(); follow the ISO 18453 execution rule
in neqsim-standards-lookup and the dew-point guide.
Recalculate outputs from the former non-convergent solver before comparing models. Neither an
ideal-gas estimate nor a CPA/GERG difference alone identifies an ISO implementation error.
- Numerics: for N >= 100 film cells use
solve_ivp(method="BDF"); LSODA stalls on the film-exhaustion
switch. Regularise r = W/(M + delta) so a film-free cell cannot return a spurious composition.
2. Wax Analysis
Wax Appearance Temperature (WAT)
// Oil system with C7+ fractions for wax prediction
SystemInterface oil = new SystemSrkEos(273.15 + 60, 50.0);
oil.addComponent("methane", 0.30);
oil.addComponent("ethane", 0.10);
oil.addTBPfraction("C7", 0.10, 92.0 / 1000, 0.727);
oil.addTBPfraction("C10", 0.15, 134.0 / 1000, 0.78);
oil.addTBPfraction("C15", 0.15, 206.0 / 1000, 0.83);
oil.addPlusFraction("C20", 0.20, 350.0 / 1000, 0.88);
oil.getCharacterization().setWaxModel(true);
oil.getCharacterization().characterisePlusFraction();
oil.setMixingRule("classic");
ThermodynamicOperations ops = new ThermodynamicOperations(oil);
ops.calcWAT();
double wat_C = oil.getTemperature() - 273.15;
Wax Fraction vs Temperature (PVT Simulation)
import neqsim.pvtsimulation.simulation.WaxFractionSim;
WaxFractionSim waxSim = new WaxFractionSim(oil);
waxSim.setTemperaturesAndPressures(new double[] {333.15, 313.15, 293.15, 273.15},
new double[] {5.0, 5.0, 5.0, 5.0}); // K, bara
waxSim.runCalc(); // run() only prepares the operations object
double[] waxFractions = waxSim.getWaxFraction(); // wax mass / feed mass
The fluid needs addSolidComplexPhase("wax"), setMultiphaseWaxCheck(true) and
getWaxModel().addTBPWax(); for named n-paraffin feeds see the neqsim-wax-calculations skill
("Named n-paraffin feeds").
3. Asphaltene Stability
de Boer Screening
// Assess asphaltene precipitation risk
// Key parameters: reservoir pressure, bubble point, density difference
// Risk increases when operating pressure approaches bubble point
// High-risk zone: ΔP > 200 bar above bubble point for light oils
// Use CPA for asphaltene modeling
SystemInterface aspFluid = new SystemSrkCPAstatoil(273.15 + 90, 300.0);
// Add components including heavy asphaltenic fractions
aspFluid.setMixingRule(10);
ThermodynamicOperations ops = new ThermodynamicOperations(aspFluid);
ops.TPflash();
aspFluid.initProperties();
// Check if asphaltene phase is stable
// Compare upper/lower asphaltene onset pressures vs operating P
Calibrated onset envelope, blends and gas injection (`AsphalteneSolidModel`)
With a measured onset, use the calibrated solid model (Nghiem and Coombe). It anchors the solid
asphaltene fugacity at the measured onset and uses size-asymmetry k_ij (large for C1/N2/CO2, about 0 for
heavy fractions), so one host calibration predicts blends and gas injection:
AsphalteneSolidModel model = new AsphalteneSolidModel(hostOil); // one component named *asphalten*, SRK/PR, classic
model.calibrate(363.15, 250.0); // measured upper onset (K, bara)
model.calibrateLowerOnset(80.0); // optional: lower onset below the bubble point
AsphalteneSolidModel.OnsetResult env = model.onsetPressures(363.15, 500.0, 20.0, 5.0);
double blendOnset = model.onsetPressures(blendFluid, 363.15, 600.0, 20.0, 5.0).getUpperOnsetPressure();
double fraction = model.precipitatedFraction(hostOil, 363.15, 200.0);
Gotchas:
- Do not tune k_ij against the database solid reference to hit a measured onset: it needs negative
asphaltene-methane values and then predicts that condensate stabilises the oil (wrong sign). Calibrate
the solid reference instead (measured 2026-11-22, see docs/pvtsimulation/flowassurance/asphaltene_modeling.md section 9).
- Always check
isAsphalteneLiquidSplitDetected(); if the EoS splits the asphaltene into its own liquid use
omega 1.2-1.5 for the solid model. (Before 2026-11-22 the Pedersen correlation gave omega = 2.5 at
1000 g/mol through a natural-log error; it now gives 1.18 at 1.10 g/cm3. Tc also gained its missing
density term and Pc its atm-to-bar conversion, so Pedersen onsets from before that date differ.)
PedersenAsphalteneCharacterization.calculateOnsetPressureraisesIllegalStateExceptionwhen the fluid
is already split at the start pressure. AsphalteneOnsetFunction (fitting) instead returns finite
penalties: the start pressure if already unstable, the minimum pressure if no onset is found.
BINARY_INTERACTION and MOLAR_MASS fits now act (both had no effect before 2026-11-22); MOLAR_MASS
holds the asphaltene mass and is cubic-only; ASSOCIATION_PARAMETERS/COMBINED need CPA, energies in J/mol.
fitKijExponentneeds a blend/gas-injected fluid or another temperature; for the calibration fluid at
the calibration temperature it throws (the objective is flat there).
Detection, onset flashes and screening (changed 2026-11-22)
- Asphaltene components:
AsphalteneComponents.isAsphaltene(name)(contains "asphalten" or starts with
"asph_"); addDistributedAsphaltene now names slices Asphaltene_1_PC... from a mass-conserving gamma
split. Asphaltene-rich phase = more than 50 wt % asphaltene (was mol %).
AsphalteneOnsetPressureFlashalso finds the lower onset (getLowerOnsetPressure()); unknown units
(including bare "psi") throw. AsphalteneStabilityAnalyzer.calculateOnsetPressure(T, startP) starts at
the given pressure; the envelope has 4 rows (T, upper, lower, bubble point at T); the assessment combines
SARA and thermodynamic risk.
- De Boer boundaries are ordered (no-problem <= slight <= severe);
AsphalteneStabilityAnalyzer.deBoerScreening
delegates to DeBoerAsphalteneScreening. Risk index for 350/150 bara at 750 kg/m3 is 200/120 = 1.667.
Flory-Huggins (`FloryHugginsAsphalteneModel`)
FloryHugginsAsphalteneModel fh = new FloryHugginsAsphalteneModel(liveOil, 373.15);
fh.setAsphalteneWeightFraction(0.03);
fh.calibrateToOnsetPressure(373.15, 250.0); // with a measured onset; otherwise calibrateCorrelation(T) (heuristic prior)
fh.setSolubilityParameterMethod(FloryHugginsAsphalteneModel.SolubilityParameterMethod.EOS); // optional
double onset = fh.calculateOnsetPressure(373.15);
Onsets computed before 2026-11-22 are unreliable: the Newton solver for the solubility limit did not
converge (phi of about 1e-19, residual about -45). The heuristic prior gives 12.4 % AARD, all
under-predicted, on the 7 benchmark cases (2026-11-22); its fixed 0.35 MPa^0.5 margin sets the result.
SARA characterization with CPA resin
AsphalteneCharacterization.addAsphalteneComponents(fluid, nC7plus) needs setC7plusProperties first,
adds asphaltene and a Resin_PC pseudo-component (2B sites in SRK-CPA), and after
fluid.setMixingRule(10) call applyCrossAssociation(fluid) to set the asphaltene-resin bond. Default
asphaltene association volume is 0.005 (database value).
Regular-solution model regressed to onset data (`FloryHugginsAsphalteneModel`)
Needs no asphaltene component in the fluid: oil density from any EOS gives the oil solubility parameter
(delta_L = 0.017347 rho + 2.904), and the asphaltene solubility parameter is the fitted quantity.
FloryHugginsAsphalteneModel fh = new FloryHugginsAsphalteneModel(liveOil, 373.15);
fh.setAsphalteneWeightFraction(0.03); // n-C7 asphaltenes, weight fraction
double deltaA = fh.calibrateToOnsetPressure(373.15, 300.0); // one measured AOP (K, bara), reproduced exactly
// or several temperatures: fits delta_a(Tref) and d(delta_a)/dT
FloryHugginsAsphalteneModel.OnsetFitResult fit = fh.fitToOnsetData(new double[] {333.15, 353.15, 373.15},
new double[] {340.0, 318.0, 300.0});
double upper = fh.calculateOnsetPressure(373.15, 500.0, 1.0); // (T, start P, min P)
double lower = fh.calculateLowerOnsetPressure(373.15, 500.0, 1.0); // NaN if it does not redissolve
- Without onset data (
configureFromAPIGravity+configureFromSARA+calibrateCorrelation) the result is a
screening estimate: calibrateCorrelation assumes a stability margin at reservoir conditions, it is not a fit.
Do not combine it with calibrateToOnsetPressure/fitToOnsetData.
- The fitted
delta_ais tied to the EOS density; recalibrate after retuning the fluid. - Choosing between calibrated models:
AsphalteneSolidModelwhen the fluid has an asphaltene component and
blends/gas injection matter (k_ij carries the composition effect); FloryHugginsAsphalteneModel when only a
characterized oil without asphaltene component and AOP data at one or more temperatures exist;
AsphalteneOnsetFitting for CPA association parameters. No head-to-head accuracy comparison on measured
data has been made (2026-11-23); the Flory-Huggins regression is verified on synthetic onsets only.
3b. Naphthenates and Organic Acid Soaps
NaphthenatePrecipitationModel (neqsim.pvtsimulation.flowassurance): equilibrium of monoprotic naphthenic
acids (TAN) and ARN tetraacids with calcium in produced water. pH is given (setWaterPH) or calculated from
CO2 partial pressure and bicarbonate (setCO2PartialPressure), which captures the pH rise on depressurisation.
NaphthenatePrecipitationModel m = new NaphthenatePrecipitationModel();
m.setWaterCut(0.5);
m.setOilDensity(850.0); // kg/m3
m.setTotalAcidNumber(1.0); // mg KOH/g
m.setAcidMolarMass(300.0); // g/mol
m.setArnConcentration(10.0); // mg/kg oil
m.setWaterComposition(1000.0, 10000.0, 500.0); // Ca, Na, HCO3- mg/L
m.setTemperature(333.15);
m.setCO2PartialPressure(0.2); // bara, e.g. yCO2 * P of the separator gas
m.run();
m.getWaterPH(); m.getRisk(); // NO_RISK, LOW_RISK, SOAP_RISK, ARN_DEPOSIT_RISK
m.getPrecipitatedArnNaphthenate(); // kg/m3 oil
m.getPrecipitatedCalciumSoap(); // kg/m3 oil
m.calculateArnOnsetPH(); m.calculateCalciumSoapOnsetPH();
- Defaults for log P, pKsp (soap) and pK (ARN) are engineering defaults anchored to typical onset pH, not
published constants. Uncalibrated results are for ranking and sensitivity; isCalibrated() is false and
the output carries a warning. State this in any report.
- Calibrate with
NaphthenateModelFitting:addObservation(scenario, ObservationType, measured, stdDev),
addFitParameter(Parameter), solve(), applyTo(model). Observation types: AQUEOUS_ORGANIC_ACID (mg/L),
PRECIPITATED_CALCIUM_SOAP (kg/m3 oil), PRECIPITATED_ARN_FRACTION, ARN_ONSET_PH,
CALCIUM_SOAP_ONSET_PH, WATER_PH. pKa and log P are not separately identifiable from partition data:
fit one. getStandardError returns NaN for a parameter the data do not determine.
- Equilibrium potential only (no kinetics or deposition rate); only calcium forms solids.
- Guide:
docs/pvtsimulation/flowassurance/naphthenate_precipitation.md.
4. Pipeline Hydraulics
Simple Adiabatic Pipe
AdiabaticPipe pipe = new AdiabaticPipe("Export Pipeline", feedStream);
pipe.setLength(50000.0); // 50 km in meters
pipe.setDiameter(0.508); // 20 inch in meters
pipe.setInletElevation(0.0);
pipe.setOutletElevation(-350.0); // negative = downhill (subsea)
pipe.run();
double outletP = pipe.getOutletStream().getPressure(); // bara
double outletT = pipe.getOutletStream().getTemperature() - 273.15; // C
double dP = feedStream.getPressure() - outletP; // pressure drop
DNV-RP-F105 free-span routing
When a hydraulics or environment study feeds an explicit current DNV-RP-F105 2025-12 free-span
screen, route verified structural and environmental inputs through
DnvRpF105FreeSpanScreeningKernel. Keep steel and hydrodynamic diameters distinct and use velocities
normal to the span. Effective modal mass, axial force, span geometry, and response-trigger basis are
external structural inputs, not quantities inferred silently from a hydraulic pipe object.
The kernel is a simply supported first-mode/dimensionless escalation screen. Its Strouhal number,
frequency-ratio band, and reduced-velocity triggers are project-controlled and cannot be called DNV
limits. Keep soil/shoulder and multi-span response, VIV amplitudes, direct wave loading, ULS/FLS,
fatigue, monitoring, and intervention external. Never relabel
PipeMechanicalDesignCalculator.calculateAllowableSpanLength(...) as F105 evidence.
DNV-RP-F101 inspected metal-loss routing
When inspection data feeds an explicit current DNV-RP-F101 2019-09+AMD:2025-09 screen, route one
verified isolated longitudinal metal-loss defect under internal pressure through
DnvRpF101CorrodedPipelineScreeningKernel. Require the measured depth and axial length,
assessment wall-thickness definition, inspection/growth allowance, characteristic ultimate
tensile strength, internal/external absolute pressures, and project-controlled pressure factor.
Do not infer defect geometry from hydraulic corrosion-rate calculations or projected uniform wall
loss. The typed kernel does not handle defect interaction or complex profiles, longitudinal
compression, probabilistic assessment, crack-like damage, repair, or fitness-for-service approval.
It also does not replace DNV-ST-F101 original-design checks.
DNV-RP-F104 CO2 pipeline routing
When an actual-composition phase-envelope and hydraulic/thermal study feeds a current
DNV-RP-F104 2021-02+AMD:2021-09 screen, route the bounded project composition, CO2/water limits,
ordered profile, absolute MAOP, design temperatures, and a separately verified minimum single-phase
pressure boundary at each point through DnvRpF104Co2PipelineEnvelopeScreeningKernel.
The external thermodynamic basis must establish that pressure above each boundary represents the
intended single-phase region for the specific composition, temperature, path, EOS, and uncertainty.
Do not substitute pure-CO2 critical conditions or CO2FlowCorrections.isDensePhase(...). Treat
composition, phase-boundary, MAOP, and temperature margins as screening findings. Keep transient
cases, F104 decompression/fracture and crack arrest, materials/corrosion, release consequences,
construction, operation, requalification, and all DNV-ST-F101 structural checks external.
DNV-RP-F114 pipe-soil interaction routing
When route, hydraulic/thermal, or installation work feeds a current DNV-RP-F114 2021-05 screen,
route named design situations with externally verified vertical, axial, and lateral action and
resistance magnitudes through DnvRpF114PipeSoilInteractionScreeningKernel. Treat margin and
utilization outputs as caller-controlled screening findings.
Do not convert burial depth, soil thermal resistance, or a generic friction factor into
geotechnical resistance. Keep site investigation, soil interpretation, penetration/burial and
load-displacement response, time/cyclic effects, characteristic values, uncertainty, structural
actions, and F109/F110/F105/ST-F101 acceptance external.
DNV-RP-F110 global-buckling response routing
When hydraulic/thermal, route, or installation work feeds a current
DNV-RP-F110 2019-09+AMD:2021-09 screen, route named external structural-analysis cases through
DnvRpF110GlobalBucklingResponseScreeningKernel. Supply effective force, peak longitudinal strain,
peak global displacement, and required feed-in length with caller-controlled allowable or available
values. Treat margins and utilizations as screening findings.
Require external evidence for the effective-force derivation, pipe/as-laid geometry, pipe-soil
response, imperfections/triggers/strategy, global structural model, load combinations, local
capacity and strain criteria, uncertainty/sensitivity/buckle sharing, and lifecycle actions. Never
derive critical buckling, initiation/prevention criteria, structural response, or soil springs from
NeqSim hydraulic or thermal output. Keep F109/F114/F105 and all ST-F101 acceptance external.
Beggs and Brill Multiphase Correlation
PipeBeggsAndBrills pipe = new PipeBeggsAndBrills("Subsea Flowline", feedStream);
pipe.setPipeWallRoughness(5e-5); // meters
pipe.setLength(50000.0); // meters
pipe.setAngle(0.0); // horizontal
pipe.setDiameter(0.254); // 10 inch
// For subsea with heat loss
pipe.setOuterTemperature(277.15); // 4°C seawater
pipe.run();
// Get flow regime, liquid holdup, pressure profile
double outP = pipe.getOutletStream().getPressure();
double outT = pipe.getOutletStream().getTemperature() - 273.15;
Liquid Holdup, Flow Regime & Liquid-Loading (gravity-dominated screening)
Verified reader methods on PipeBeggsAndBrills (after run()):
String regime = pipe.getFlowRegime(); // SEGREGATED / TRANSITION / INTERMITTENT / DISTRIBUTED
double dP = pipe.getPressureDrop(); // bar (inlet - outlet)
double vmix = pipe.getMixtureVelocity(); // m/s
double[] holdupProfile = pipe.getLiquidHoldupProfile(); // fraction per segment (0-1)
// per-segment access (0 .. numberOfIncrements-1):
Double hSeg = pipe.getSegmentLiquidHoldup(i);
Double vsgSeg = pipe.getSegmentGasSuperficialVelocity(i);
Double vslSeg = pipe.getSegmentLiquidSuperficialVelocity(i);
Double elevSeg = pipe.getSegmentElevation(i);
// average holdup = mean(holdupProfile); "liquid content" for the line
// liquid inventory (m3) = sum_i holdup_i * (pi/4*D^2) * segmentLength
Liquid-loading / gravity-dominated screening (PEPR-style "is the line filling
with liquid?"): sweep gas rate (and water cut) and read average holdup +
regime. As gas rate falls, holdup rises and the regime moves
INTERMITTENT -> TRANSITION -> SEGREGATED (stratified) = gravity-dominated /
liquid loading. Higher water cut lifts holdup at every rate and pushes toward
INTERMITTENT (slugging). Define liquid-loading onset as the gas rate where
average holdup crosses a threshold (e.g. 25%).
for (double qgMSm3d : gasRates) {
SystemInterface feed = fluidTemplate.clone(); // gas-condensate + water (CPA, rule 10)
Stream s = new Stream("feed", feed);
s.setFlowRate(qgMSm3d, "MSm3/day"); // wellstream gas standard volume
s.setTemperature(50.0, "C"); s.setPressure(150.0, "bara");
s.run();
PipeBeggsAndBrills p = new PipeBeggsAndBrills("line", s);
p.setLength(21000.0); p.setDiameter(0.254); p.setAngle(0.0);
p.setPipeWallRoughness(5e-5); p.setNumberOfIncrements(40);
try {
p.run();
double[] h = p.getLiquidHoldupProfile();
// record mean(h), p.getFlowRegime(), p.getMixtureVelocity()
} catch (RuntimeException e) {
// "Outlet pressure is negative" = DELIVERABILITY LIMIT, not a bug (see gotcha)
}
}
GOTCHA — deliverability limit vs bug.
PipeBeggsAndBrillsuses a **fixed
inlet pressure**. If frictional ΔP over a long/small line exceeds the inlet
pressure,
run()throws `InvalidOutputException: ... Outlet pressure is
negative`. That is a genuine deliverability limit (the line cannot pass
that rate at that inlet P), not a solver failure — catch it and report the
max deliverable rate. To model to a fixed arrival (outlet) pressure
instead, raise the inlet pressure until the delivered rate matches, or iterate
inlet P per rate.
PATTERN — tubing outflow (VLP) and gas-lift need on a heavy-oil tie-back. Put the bottom-hole
pressure on the inlet stream (
P_bh = P_res - q_liq / PI), setsetLength(MD),setElevation(+TVD),
setAdiabatic(true)and read the outlet pressure as the wellhead pressure; add lift gas as extra gas in the
stream composition (bottom injection slightly over-states the lift). A 24 API oil (10 cP at 85 C) with 2000 m TVD
has a hydrostatic head of about 170 bar, so a 205 bar reservoir cannot reach a 40 bar arrival without lift: sweep
water cut x rate x lift GLR once, tabulate the WHP margin against
arrival + line dP + choke, and read the
deliverable rate per well and the GLR needed from the table (it falls from about 2.5 kSm3/d per well at 5 % water cut
to zero near 85 %). Every
None/exception in the table is the deliverability limit above, not a failure.
getMixtureViscosityProfile()/getSegmentMixtureViscosity()return cP, not Pa.s (do not multiply by 1000).
GOTCHA —
getFlowRegime()naming. Beggs & Brill regimes are returned as
SEGREGATED(stratified/annular — gravity-dominated),TRANSITION,
INTERMITTENT(plug/slug),DISTRIBUTED(bubble/mist). "Gravity-dominated /
liquid loading" = SEGREGATED (+ low-velocity TRANSITION).
GOTCHA — profile index vs
getFlowRegime().run()evaluates the
correlation once per increment and then once more at the outlet state, so
every correlation profile (
getLiquidHoldupProfile(),
getFlowRegimeProfileList(), …) hasnumberOfIncrements + 1entries and
index i belongs to
getPressureProfile()[i].getFlowRegime()returns the
outlet state. Reading
getFlowRegime()next to
getSegmentLiquidHoldup(0)compares two different states and can look like a
discontinuity. Always pair
getSegmentFlowRegime(i)with
getSegmentLiquidHoldup(i).
VALIDITY — low liquid loading. On a long wet-gas export line (ID 0.355 m,
no-slip liquid fraction λ_L ≈ 0.006), Beggs & Brill over-predicts ΔP well above
a single-phase Darcy-Weisbach integration of the same line, and the gap is
entirely the two-phase friction multiplier
exp(S): removing it brings ΔP
within 4% of that analytic integration.
Sis monotonically increasing
in
y = λ_L / H_L², so less liquid gives a larger multiplier — the
opposite of the physical trend — up to a bounded maximum of
exp(S) = 3.19at
y = 52.1. B&B is calibrated for λ_L down to roughly 0.01–0.02; below that,
use
TwoFluidPipeor a mechanistic simulator and treat B&B as a conservative
upper bound. The published map also has a genuine step where the segregated and
distributed correlations meet at
L1for λ_L < 0.01 (no transition band
exists there): hold-up ×0.70 and ΔP ×1.12 across a 1 bara change. That step is
in the correlation — do not smooth it.
Fixed defects worth knowing (all affected the inclination correction).
Older NeqSim builds silently returned the horizontal hold-up on an inclined leg
when (a) the pipe angle was converted degrees→radians twice, (b) the
Baker-Swerdloff surface tension went negative above 274 bara or for a very
light liquid, making the liquid velocity number NaN, or (c) the flow regime was
TRANSITION, which had no inclination branch at all. All three are fixed and
locked by
PipeBeggsAndBrillsCorrelationTest. If you are on an older build,
sanity-check that uphill hold-up clearly exceeds horizontal hold-up before
trusting an inclined result.
Phase-count code paths.
PipeBeggsAndBrillsassumes phase 0 is the gas
whenever the stream has more than one phase. A gas-free stream that splits
into oil and water (dead oil with free water at high pressure) used to be
modelled as gas–liquid, with the oil phase acting as the gas: fictitious flow
regime, hold-up 0.21 instead of 1, and ΔP 44% above the homogeneous liquid
value. It is now carried as a homogeneous liquid with a volume-weighted density
and viscosity. The three-phase liquid density is also now combined on volume
fractions (total mass over total volume) rather than mass fractions. Locked by
PipeBeggsAndBrillsPhasePathsTest.
Where the error sits. On a single-phase gas line Beggs & Brill matches a
Darcy-Weisbach integration to a few tenths of a per cent on pressure drop and to
~0.15 K on arrival temperature — the friction and energy paths are sound. The
over-prediction seen on the two-phase version of the same line is therefore
entirely the two-phase friction multiplier, not the solver.
**Comparisons against commercial transient multiphase simulators are not
published in this repository.** Their licence terms generally prohibit
publishing benchmark results and prohibit using the software to develop
competing software, so no NeqSim closure is tuned to such a tool and no measured
deviation against one is recorded here. Validate against experimental,
laboratory or field data, or against an analytic/first-principles check.
TwoFluidPipesteady-state usage. Gate every result on the complete
immutable
SteadyStateConvergenceReport, not a stationary pressure trace or
iteration count. Require
isConverged(), inspect the explicit termination
reason, and retain pressure-momentum, pressure-update, total-liquid-holdup,
water/oil-split, thermodynamic-property, and total-pressure-drop residuals
against the report's unchanged tolerance. Pressure-floor and wall-clock
termination are non-converged. Repeat mesh sensitivity for the actual
geometry; no fixed cell length is universally qualified.
**
TwoFluidPiperun time (measured 2026-11-22, revision a2399c6 before and after
the closure-reuse change; 5.4 km 8-inch three-phase flowline and riser at 60 and
120 cells, 20 km 16-inch gas-condensate line at 100 cells; OpenJDK 21, one
thread).** Steady
run()takes 1.23 s at 60 cells and 4.14 s at 120 cells
(was 1.60 and 5.60 s); 60 s of transient on the 60-cell line takes 13.6 s
(was 24.2 s), with identical profiles. Equilibrium flashes are now the largest
remaining cost (
TPflashis 48% of that transient case and 69% of the gas-condensate
steady solve), so run time scales with cells x flash cadence x fluid complexity. Budget
studies on that basis: screen sensitivities with
PipeBeggsAndBrills
(0.04 s per 100 increments on the same feed) and keep
TwoFluidPipefor the
cases that need section-resolved holdup, inventory or transients. The cadence
setters are
setSteadyStateFlashInterval(int)(default 3) and
setThermodynamicUpdateInterval(int)(default 10); on that transient an interval
of 20 saved 27% of the transient time and moved the inlet pressure by 0.14 bar
after 60 s, so a longer interval is a model change to check per case. Details and
the two benchmark entry points:
MCP
runPipelinesolver and response handoff. Omitsolver(or use
beggsBrill) for the established correlation path. Usesolver: "twoFluid"
when the task needs finite-volume pressure, temperature, holdup, phase-velocity,
flow-regime, inventory, erosion-margin, hydrate/wax, or slug profiles. Pass
sectionLengths_m,elevationProfile_m,heatTransferProfile_W_m2K, and
surfaceTemperatureProfile_Cor_Kas equal-length per-section arrays; the
lengths must sum to
length_m. Bound expensive solves with
steadyStateMaxWallClockTime_s. RequestdetailLevel: FULLfor spatial
profiles,
SUMMARYfor engineering KPIs without profiles, orMINIMUMfor
the compact core result. The authoritative object is
TwoFluidPipeResponse
(a
BaseResponse): preserve it through MCP/report handoffs instead of
independently reconstructing fields from the equipment. Always propagate its
convergence/pressure-floor/wall-clock validation findings and apply the
limitations below before quoting a result.
**Three defects found by auditing the solve against its own governing equations
— all fixed, but the symptoms are generic and worth recognising elsewhere.**
(1) A time integrator inside a fixed-point sweep. The steady solve integrated
LiquidAccumulationTrackeronce per iteration with a nominaldt; that tracker
only ever adds liquid, ratchets its volume up to what the sections already hold,
then adds it back on top of that holdup, so it has no fixed point. Valley
sections climbed to the 0.85/0.95 cap and the profile never settled.
(2) A correlation overriding a solved momentum balance. The minimum-slip
constraint applied the Beggs and Brill horizontal holdup correlation as a lower
bound in every regime. It is fitted to 1–1.5 inch air-water loops at
near-atmospheric pressure with λ_L ≥ 0.01; the line runs λ_L ≈ 0.008
in a 14-inch pipe at 200 bara, and the floor was binding in EVERY section — so
the reported holdup was the correlation, not the solved momentum balance, worth
≈+20% on ΔP through the mixture density. Only the scale-free
lambdaL * minimumSlipFactorbound remains.
(3) Convergence declared without re-evaluating thermodynamics. The flash runs
every
ssFlashIntervalsweeps but the "flash moved nothing" flag started false,
so a non-flash sweep read as settled. The solve could exit after ONE sweep on
densities it had never revisited.
If you see a steady profile with a section sitting exactly on a cap, or
getSteadyStateIterationsUsed()returning 1 on a long line, suspect these.
Behaviour after those fixes, on that line at default settings: the rate
exponent in ΔP ~ rate^n rises from about 2.1 to about 3.1 across a 3x rate
range, i.e. the density feedback along the line is reproduced, not just the
level at one rate; 10 MW of DEH raises arrival T by ~17 K and ΔP by ~15%, so the
energy equation feeds the momentum balance. Grid-converged (160 vs 320 sections
within 0.4%). Terrain response is solved, not tuned: the annular film balance
carries
tau_i = tau_wL + rhoL*g*sin(theta)*delta, so holdup responds to
inclination and scales with
sin(theta). The compact public 3 km,
10-degree uphill gas/oil/water fixture is annular with dispersed oil and water
and converges on 30 and 60 cells without oil-water slip, with 0.922%
arrival-pressure and 0.138% mean-liquid-holdup sensitivity (rerun 2026-11-15)
and every final report residual below
1e-4. This is numerical verification, not
experimental qualification. The historical 73.8 km / 15 m3/hr free-water
input is unavailable, so the earlier 4,078-iteration / 1,200 s report cannot
be reproduced or claimed fixed. Never generalize the compact result to that
unavailable case.
TwoFluidPipealso fails silently when a line has no deliverability. The
marching solver clamps section pressure at a 1 bara floor; that clamp is a
fixed point of itself, so the per-section change falls below tolerance and the
sweep would report success on a case with no physical solution. Check
pipe.isSteadyStatePressureFloorLimited()— when it is true,
isSteadyStateConverged()is withheld and the profile must be discarded, not
reported.
PipeBeggsAndBrillsthrowsOutlet pressure is negativeon the same
condition.
TwoFluidPipeholdup at low rate is dominated by terrain trap sections.
The MAXIMUM holdup at 4 and 7 MSm3/d sits well above the line mean (a single
valley section), so do not
quote local
TwoFluidPipeholdup or valley inventory as a design number. The
three-phase bookkeeping is sound — gas/oil/water fractions sum to one and stay in
range at every node.
The minimum-slip bound applies only level and uphill. `alphaL >= lambdaL *
minimumSlipFactor` (default 2.0) states that the gas outruns the liquid, which is a
property of gas-driven transport. On a downhill section gravity moves the liquid and
the slip ratio legitimately falls, so the bound is not applied there. It used to be
applied everywhere and was binding on 39 of 42 downhill sections of an undulating
fixture, replacing the momentum balance with a constant.
The horizontal annular criterion is the Taitel-Dukler equilibrium level.
pipe.setUseEquilibriumLevelAnnularTransition(false)restores the earlier path, the
vertical droplet-entrainment threshold
U_SG > 3.1*(sigma*g*drho/rhoG^2)^0.25, which is
about 0.75 m/s on a 14-inch export line and so classified essentially any horizontal gas
pipeline as annular, solving a shallow stratified layer with a thin-film closure. The two
agree wherever the Kelvin-Helmholtz margin exceeds one — identical at 10 MSm3/d on the
export line — and differ at 4 MSm3/d, where the equilibrium branch reclassifies 272 of 320
sections as stratified-wavy.
Transient closure sources follow continuous regime weights. During dynamic
evaluation, the existing dimensionless normalized weights from
FlowRegimeDetector.classify(...)blend wall friction, interfacial friction and area,
and entrainment. A non-zero stratified weight keeps the matching segment geometry active.
The flow map, transition bands, hold-up closure, and regime-specific formulas are unchanged,
and pure-regime endpoints recover their original closures. This is experimental numerical
continuation, not severe-slugging or liquid-rich qualification; require the public Tengesdal,
1,800 s inventory, conservation, nearby-point, refinement, and solver-diagnostic gates.
Friction is per-phase wall shear in stratified flow.
setSeparatedFrictionModel(false)restores the mixture correlation, which charges the whole
perimeter with a holdup-weighted density; on a stratified line at 41% holdup that
over-predicts ΔP by ~2.3x, and because it scales as
G^2/rho_mixit makes extra liquid
REDUCE the gradient, inverting the terrain response. The separated form is scoped to
stratified flow because its perimeters come from a circular-segment layer; annular flow,
whose film wets the whole perimeter, is not that geometry.
The historical 73.8 km comparison is not a public qualification basis.
Its complete input and measurement package is unavailable in the repository,
so earlier reported pressure-drop and holdup deviations are retained only as
repair history. Do not route or certify a study from those values. Use the
reproducible public evidence and explicit failed/unsupported rows in the
TwoFluidPipe evidence matrix.
Direct electrical heating (DEH) is available on both models with the same
convention — the power set is what reaches the fluid, so cable and coating
losses must already be deducted:
pipe.setDirectElectricalHeatingPower(watts)or
setDirectElectricalHeatingPowerPerMeter(wattsPerMetre). InTwoFluidPipe
steady state each segment decays toward the balance temperature
T_surface + q/(U·π·D)(exact for a uniform source, cannot overshoot); it also
works in transient and with wall heat transfer switched off. A tool with no
distributed-heating input can represent the same source through the identity
−UπD(T−T_surf) + q ≡ −UπD(T − [T_surf + q/(UπD)]), i.e. by raising the ambient
temperature by
q/(UπD).
**
TwoFluidPipeliquid-rich and severe-slugging transients remain
unqualified.** The legacy route can still develop phase backflow and clamp the
outlet flux at zero while its finite-volume balance closes exactly. Gas-dominated
null cases remain usable, but do not promote a liquid-rich or severe-slugging
trajectory from either a small residual or a completed time loop alone. Use the
analytical
SevereSluggingBenchmarkHarnessTestscreen and the public Tengesdal
evidence until the dynamic qualification gates below pass.
Screening a gas-oil-water riser.
evaluateSevereSluggingSystem(riserBase)returns
NOT_VALIDATED_THREE_PHASEwhen a section holds both oil and water. Call
evaluateSevereSluggingSystem(riserBase, 0.89, 0.0, true)to evaluate the Taitel condition with the
in-situ oil-water mixture density of the riser column, and report
isLiquidMixtureBasis()with the
result: it has no three-phase validation and does not cover water collecting at the riser base. The
stratified-feeder check still applies, so run it at the turndown rates. Measured 2026-11-22 on a
15 km, 12-inch flowline with a 430 m riser at 73 bara: slug-flow feeder at 300 and 150 t/h (not
applicable); stratified feeder and unstable at 75 and 30 t/h (critical top pressure 494 and
800 bara).
The synthetic three-phase riser handoff is a narrower qualified lane. With phase transfer
disabled, its steady gas/oil/water mass-flow profiles are flat, dispersed oil-water drag uses
Hinze droplet area, and the unchanged-boundary 60 s replay keeps accepted phase outlet transfer
nonnegative on 60/120 cells and 0.25/0.125 s reporting steps. Check the phase profiles and
inventory ledger before applying a choke move. A pressure-coupled 65% to 58% choke step now keeps
riser water outflow positive for 150 s; the earlier zero-water intervals came from an oil-water
regime flip, not from physical redistribution (
neqsim-dynamic-simulation, equinor/neqsim#5046). Do not generalize this numerical initialization
result to slug statistics, separator control or field validation.
Finite-rate hydrocarbon pool transfer is parameterized screening. On the
conservative-energy Euler route,
HydrocarbonPoolTransferaccepts explicit
component transfer coefficients, evaporation enthalpies, interface width and
available W/m. It preserves component/momentum/energy ownership and exposes
donor/heat-limit diagnostics. Do not use an arbitrary relaxation time as a
fitted evaporation rate, and do not promote analytical conservation tests to
shutdown/restart, swept-slug, receiver-capacity or hydraulic-pigging evidence.
Calibration and validation need separate independent public multicomponent
rate data plus mesh/time and complete-cycle evidence.
The 100 W/m finite-heat 780 s rich-gas cycle is numerical mesh/time evidence. It
retains the requested dense EOS root across the cubic model's diagnostic
$V/B=1.75$ label transition while positive-compressibility, Jacobian and
energy-admissibility guards remain active. Do not clip composition or change
the configured root to manufacture a restart result.
The opt-in hydrostatic-pool mode uses volume-preserving inclined-cell area,
retains representable trace-wedge leading depth without a liquid floor, reports equilibrium
appearance and any still-sub-resolution stratified trace fallback,
and can retain an explicitly initialized wall profile across event intervals.
Use
HydrocarbonPoolTransfer.forStratifiedFlow(...)for moving circular-stratified states.
Its local holdup chord preserves total area and component sources under subdivision of a
uniform physical state. Independent stationary puddles in every numerical cell are a
different area model and introduce a cell-length kinetic dependence during flow. Preserve
the historical hydrostatic-cycle failure; the flowing alternative does not validate it.
Mesh refinement must retain physical terrain and outlet breakpoints. The wall-coupled
12/24-cell cycle fixes its final 1250 m at -333.5 m on both meshes; the earlier
"last three cells" rule compared different pipes. Retain the 10% peak/final inventory
gates and inspect the executed hydrocarbon-pool-transfer receipt. Maximum single-cell
interface area is extensive, not a convergence target. Independent mesh/time, rate/thermal
and moving-boundary conservation evidence is still required for coupled pigging.
A conservative
CONSTANT_PRESSUREinlet now reflashes its explicit or connected external
reservoir and resolves signed phase flow with acoustic impedance, carrying the same donor through
mass, named-component and enthalpy ledgers. Start a restart ramp from
getInletFacePressure("Pa"), not the first cell-centre pressure.
An explicitly isolated reservoir reuses one flash across internal stages at each pressure;
getPressureInletFlashCount()verifies that safeguard. A live connected stream remains uncached.
The declared full cycle closes on 12/24 cells and 0.5/0.25 s intervals, but one small unfiltered
opening reversal and the absence
of independent public surge data keep physical restart and distributed hydraulic pigging open.
Record refill/valve-opening pressure windows with
TwoFluidPipeReport.analyzePressureTrace(...); its unfiltered ringing metrics are numerical
diagnostics, not an independently validated surge limit.
Ideal-gas pig hydraulics is a separate reduced-order route.
IdealGasPiggingModelcouplesPigMotionto conservative upstream/downstream
calorically perfect gas inventories and reuses
IdealGasReleaseModelfor
bidirectional choked/subcritical bypass. Use it only when two well-mixed gas
control volumes are an explicit approximation. Inspect total-mass and
combined-energy residuals, timestep refinement, numerical safeguards and the
launcher/receiver ledger. The public 62 m/52 mm Hendrix geometry is
provenance, not experimental trajectory validation; other example inputs are
synthetic.
PigMotion.advanceToPositionsupplies reversal-safe first-crossing
timing for known launcher, receiver, sensor or geometry coordinates; it does not
define contact or geometry physics. Do not route it as distributed
TwoFluidPipecoupling,
pressure-wave, swept-liquid, receiver-capacity, residual-film,
physical-restart, severe-slugging, pig-train or field/commercial evidence.
Coupled component/phase/thermal slug transport has a narrower envelope.
For the conservative Lagrangian slug/film path, named-component phase sources
and their partial-enthalpy latent source must be frozen from the same
hydrodynamic RHS-stage equilibrium state. The Stage 4 closed wet-gas regression
verifies phase, total, component, interphase, and thermal ledgers around a
seeded in-domain marker. It is single-stage Euler evidence only. Multi-stage
phase appearance needs stage-local component inventories and fails before
mutation. Named-component transport with signed outlet backflow requires
setOutletBoundaryFluid(externalFluid)before
setAllowOutletPhaseBackflow(true)so reversed phase composition, density,
and enthalpy have an explicit physical owner. Never infer that state from the
last interior cell. The current rich-gas pressure-ramp check is conservative
boundary evidence, not complete blowdown, pooling, restart, or evaporation-rate
qualification. For a gas takeoff above retained liquid, use
setGasOnlyOutletTakeoff(true)only with a constant-pressure outlet. Oil and
water remain externally closed while retaining traction and internal drainage;
do not replace this contract with inventory clipping or a manufactured boundary
mixture.
A negative prescribed inlet rate uses the first pipe cell as the outflow donor;
it must not inherit the external feed phase split. Review total phase momentum
and pressure traction separately through
getLastBoundaryPhaseMomentumFluxes()and
getLastBoundaryPhasePressureForces(). Those arrays qualify the external
boundary contract only, not a complete momentum residual or physical restart.
Two severe-slugging screens exist; pick by question.
pipe.evaluateSevereSluggingSystem(riserBaseSection)is the quasi-steady Taitel
criterion on a solved
TwoFluidPipeprofile (stable/unstable, pressure margin in
Pa).
SevereSlugAnalyser(neqsim.process.measurementdevice.simpleflowregime) is
a lumped dynamic model that also returns the riser-base pressure swing
(
getPressureAmplitude()in bar,getSlugValue()dimensionless). Gotchas for the
analyser: flowline
angleis the downward inclination in degrees and must be
positive;
usgis defined atgetGasReferencePressure()(1.0e5 Pa by default, the
stream pressure for stream-based constructors); pressures are absolute Pa;
statistics use the second half of
simulationTime, which must cover at least one
cycle (order
(H + alpha*L)/usl). The slug value is normalised by absolute
pressure, so at high pressure judge severity from the amplitude against the riser
head
rho_L*g*H. Both tools lump or reject oil–water: the default Taitel call keeps
NOT_VALIDATED_THREE_PHASEand adds an all-oil/all-water bracket
(
getThreePhaseBound(),getCriticalTopPressureLowerBoundPa()/
...UpperBoundPa()); report anINCONCLUSIVEbracket as inconclusive, never as
stable. See
docs/process/severe-slug-analyser.md.
The coupled route is an opt-in four-part configuration. For a pressure
outlet that physically permits phase fallback, use
setEnableInterfacialPressure(true),
setImplicitInterfacialPressureCoupling(true),
setEnableCoupledPressureMomentum(true), and
setAllowOutletPhaseBackflow(true)together. The nonlinear controls are public:
setCoupledPressureMomentumMaximumIterations(int)and
setCoupledPressureMomentumRelativeVolumeTolerance(double), with defaults 24
and
1e-7.
WS3 restores progress, not physical parity. The 16-section Tengesdal Test 3
probe now completes 50/50 calls of 0.1 s; a 24-section refinement completes
100/100 calls of 0.05 s. Neither rejects a nonlinear substep, and gas, oil,
water, liquid, and total mass residuals are below
1e-9. The former
12-iteration cap stopped around
6e-7, above the1e-7gate. The sticky pressure
limiter still fires, however, and the liquid outlet spans -18.55 to 6.88 kg/s
versus the stored 0.375 to 4.03 kg/s comparison. This is a disclosed boundary/
pressure-coupling gap, not a reason to tune a public closure to a commercial
trace. Subsequent validation must use the public Tengesdal experiment, nearby
operating points, conservation, and mesh/time-step refinement.
What did help: fixing the regime. The same case classified SLUG rather than
ANNULAR (PR #3086, Barnea bridging limit) cuts the 30-minute inventory runaway
from +56.3% to +20.1% at default settings. Still unusable, still gated by
the flag, but the regime branch is a bigger lever on the runaway than the
interfacial-pressure term is.
The transient tells you when it has failed — always check every diagnostic.
Read
isTransientOutletBackflowClamped(),
isTransientCoupledPressureMomentumFailureDetected(),
isTransientCoupledPressureMomentumCorrectionLimited(), and
getTransientCoupledPressureMomentumRejectedSubsteps()after the full window.
isCoupledPressureMomentumPressureCorrectionLimited()is the non-sticky view
of only the latest correction.
The flags/counter are sticky and reset on the next steady
run(). A coupled
call that cannot complete its requested interval now throws with accepted time,
requested time, residual/tolerance, iterations/cap, and limiter state; never
catch it and advance the engineering timeline. The mass-balance report alone
cannot qualify the result because a clamped or limited route can still conserve
its own discrete fluxes exactly.
Three-phase (gas/oil/water) steady state is fixed. The oil/water slip
ratio uses
S = 1 + 1.75·max(0, 1 − (Fr/3)²), a stratified plateau that rolls
off to no slip once the liquid disperses above a mixing Froude number of about
3; the previous form cut off at Fr = 2 and under-predicted water holdup badly.
The Froude velocity is the bulk liquid velocity in stratified and slug flow
and the total volumetric flux in annular, churn, bubbly and mist flow, the
same mixing velocity the oil-water regime detector uses. Gas-sheared liquids
therefore carry no stratified slip into a transient that treats them as
dispersed (equinor/neqsim#5046, 2026-11-15; the horizontal in-situ water
benchmark, 0.1337, still passes).
One gap remains open: the pressure drop is over-predicted in this liquid-rich
regime, far more than on a gas-dominated line.
Exporting NeqSim to OLGA — the fluid basis is two files, not one. The
.tabPVT table fixes the phase behaviour; the hydrate boundary is separate
and OLGA does not compute it. Without a
HYDRATECURVEin the case, OLGA falls
back to the Hammerschmidt correlation, so a study whose NeqSim half uses CPA
hydrate equilibrium and whose OLGA half uses Hammerschmidt disagrees about where
hydrates form, invisibly. Export both from the same fluid:
OLGAhydrateCurveGeneratorwrites the `HYDRATECURVE LABEL=..., PRESSURE=(...)
bara, TEMPERATURE=(...) C` block and returns the matching
HYDRATECHECK HYDRATECURVE="..."line for the flowpath. OLGA interpolates that
curve linearly, so span the pressures the case actually visits and use ≥20
points when the range reaches below ~50 bara (4 points over 10–200 bara costs
4.1 K of hydrate temperature; 20 points costs 0.48 K). The OLGA output variable
is
DTHYDin °C, and it isT_hydrate − T_fluid— **positive means inside the
hydrate region**, negative is the safe margin, which is the opposite of the
intuitive reading. Full OLGA-side workflow in the community
neqsim-olga-multiphase-simulatorskill.
Check three-phase PVT keyword semantics. Use `RS = gas mass/(gas + oil
mass)`, excluding the separate aqueous phase. At standard conditions, use
GLR = gas volume/(oil + water volume)and `WC = water volume/(oil + water
volume)`; never copy GOR into GLR for a wet fluid. Omit optional multicomponent
bubble headers rather than exporting failed or inappropriate wet-fluid roots.
Regenerate older tables after the issue #4478 corrections; see
docs/integration/olga_pvt_table_generation.mdfor the no-liquid conventions
and required pure-component saturation validation.
Configure the table for the study, then hand over the report. For a
wellstream table set produced water on a water-free feed
(
setProducedWater(30.0, "watercut")), salinity (`setWaterSalinity(35000.0,
"mg/l")
), IAPWS aqueous properties (setUseReferenceWaterProperties(true)`,
applied only where the aqueous phase is >= 95 wt% water, so MEG-rich water stays
on the EOS),
setEnvelopeRefinement(true, 5.0)with >= 50 points per axis and
setInsertStandardConditions(true). Afterrun(), require
getQualityReport().isLoadable()and attachwriteTableReport("x_report.md")
and the
.tabto the study. Retrograde liquid density falling with pressure at
existing nodes is physical and is reported, not an error.
Never build a volumetric phase fraction from
phase.getVolume(). With a
Peneloux volume shift active it disagrees with
getDensity()by the shift —
+16.6% for oil and +31.7% for water on a typical SRK three-phase system, while
gas matches to 0.25%. Use
getFlowRate("kg/sec")/getDensity("kg/m3").
advection-relaxation transport lag, not a conservation-law solver, and the
Beggs & Brill correlation is not even used on that path (friction reverts to
single-phase Darcy-Weisbach, viscosity is frozen at the inlet). It **does not
store mass**: on a rate step the outlet mass flow equals the inlet at every
timestep, so
∫(ṁ_in − ṁ_out)dt = 0while the inventory implied by its own
profile moves 171 t — about 192 t of gas appears from nowhere on a 74 km line.
This is not repairable in the class as written: it takes only an inlet boundary
condition, so there is nothing to pin the arrival pressure and drive line pack.
It also does not exactly preserve its own steady state — with the boundary
conditions held constant it drifts −6.3 bar on that line (was +30 bar before
the cell-density fix), because the transient friction closure differs from the
steady one. Note also that
calculateSteadyStatedefaults to true, so
without
setCalculateSteadyState(false)runTransientis only a steady-state
solve with the clock advanced; and the time step must be shorter than the
segment transit time
L/numberOfIncrements/v, otherwise the relaxation factor
saturates at 1 and the whole line responds in a single step. Use it for transport
delay in a flowsheet; use
TwoFluidPipefor line pack, shut-in, ramps and
blowdown (0.00 bar drift on the same null test, mass balance closing to the
digit), and
WaterHammerPipefor surge.
**
TwoFluidPipeclosed-end pack-up limits (measured 2026-11-21, 15.6 km 12-inch
line, 300 t/h wet gas/oil/water, 80 cells, coupled pressure-momentum).** The
flat line packs with no rejected substep up to the saturation pressure of the
feed (255 bar at 2,400 s). Above that pressure cell pressures differ by tens of
bar again, because the gas should dissolve and the default route keeps the phase
masses frozen: use component transport with mass transfer there. With a steep
riser and a closed top the cells at the riser show velocity differences of about
10 m/s within 5 s and pressure spikes after about 30 min: do not report
closed-riser-top pressures from the model.
Gray (1974) Correlation — Gas / Gas-Condensate Vertical Wells
PipeGray implements the Gray (1974) correlation, the industry standard for
gas-dominated vertical wells producing condensate and/or water (API 14B
program). Prefer it over Beggs & Brill for vertical/near-vertical gas-condensate
tubing where the superficial gas velocity is high (> ~4.6 m/s), the tubing is
small (< ~3.5 in), and condensate loading is low (< ~50 bbl/MMscf). It predicts
in-situ liquid holdup and a condensate-film effective roughness.
PipeGray well = new PipeGray("Gray well", inletStream); // gas-condensate wellstream
well.setDiameter(0.0889); // 3.5 inch tubing
well.setLength(3000.0);
well.setElevation(3000.0); // vertical well (upward flow)
well.setNumberOfIncrements(10);
// Optional: swap the holdup closure to Woldesemayat-Ghajar (2007)
well.setHoldupMethod(PipeGray.HoldupMethod.WOLDESEMAYAT_GHAJAR);
well.run();
double dP = well.getTotalPressureDrop(); // bar
double holdup = well.getLiquidHoldup(); // fraction (0-1)
double vsg = well.getSuperficialGasVelocity(); // m/s
double ke = well.getEffectiveRoughness(); // m (Gray condensate-film roughness)
Single-phase gas and single-phase liquid segments fall back to a Haaland
friction-factor Darcy-Weisbach drop, so the same model spans wet-gas wells that
drop out condensate along the tubing. The void-fraction closures are exposed
directly via VoidFractionCorrelations.woldesemayatGhajar(...).
Pipeline with Formation Temperature Gradient (Wells / Risers)
PipeBeggsAndBrills wellbore = new PipeBeggsAndBrills("Production Well", feedStream);
wellbore.setLength(3000.0);
wellbore.setElevation(-3000.0); // vertical well
wellbore.setDiameter(0.1571); // 6-5/8 inch
wellbore.setPipeWallRoughness(5e-5);
// Formation temperature: 90°C at bottom, gradient of -0.03°C/m going up
wellbore.setFormationTemperatureGradient(4.0, -0.03, "C");
wellbore.run();
Pipeline Sizing (Iterative)
// Iterate over diameters to find optimal size
double[] diameters = {0.1524, 0.2032, 0.254, 0.3048, 0.3556, 0.4064, 0.508};
// 6", 8", 10", 12", 14", 16", 20"
for (double d : diameters) {
Stream testFeed = new Stream("feed", feedFluid.clone());
testFeed.setFlowRate(flowRate, "kg/hr");
testFeed.run();
PipeBeggsAndBrills testPipe = new PipeBeggsAndBrills("test", testFeed);
testPipe.setLength(pipeLength);
testPipe.setDiameter(d);
testPipe.setPipeWallRoughness(5e-5);
testPipe.run();
double dP = testFeed.getPressure() - testPipe.getOutletStream().getPressure();
double velocity = testPipe.getSuperficialVelocity();
// Check: erosional velocity < API RP 14E limit, dP within allowable
}
5. CO2 / H2S Corrosion Assessment
CO2 Partial Pressure Based Screening
// After flash calculation
fluid.initProperties();
double pCO2 = fluid.getPhase("gas").getComponent("CO2").getx()
* fluid.getPressure(); // CO2 partial pressure in bara
// NORSOK M-001 / DNV-RP-F112 screening:
// pCO2 < 0.02 bar → low risk (carbon steel OK)
// 0.02 < pCO2 < 0.2 → moderate (corrosion allowance or inhibitor)
// pCO2 > 0.2 → high risk (CRA or heavy inhibition)
Temperature and pH Effects
// Corrosion rate increases with temperature up to ~80°C
// then decreases due to protective FeCO3 film
// Lower pH (more acidic) → higher corrosion rate
// Water cut affects wetting: >30% water cut → higher risk
Sour service (H2S cracking) screening for compressors and vessels
H2S cracking (SSC) is a materials question, not a corrosion rate: ISO 15156-2 (NORSOK M-001 cl. 6.1.3) calls the service sour when the wet gas has
pH2S >= 0.3 kPa at total pressure >= 0.4 MPa, and dehydration or chemical treatment give no relief. Screen it as follows (task 2026-10-21 Vigdis/Snorre compressors):
- Express the limit as H2S in the gas for each machine pressure:
y_limit = 0.3 kPa / P(24 ppm at 125 bara, 10 ppm at 300 bara, 100 ppm at 30 bara). Check
both suction and discharge; the high-pressure machines go sour first because the ppm is constant while P rises.
- Get y_H2S per machine from a process model with H2S as a trace component (the system is linear: run once and scale), or from the stream composition; use
y x P (Dalton) for classification and the fugacity coefficient (getFugacityCoefficient(), 0.2-0.4 in dense injection gas) as sensitivity only.
- When the H2S source is not in the model (e.g. degassing-tank gas recovered from a flare), carry it with a dilution share f (
y_mix = f x y_source) and report the
break-even f = 0.3 kPa / (y_source x P) plus a Monte Carlo, instead of a single number.
- Report in-situ pH of the condensed water (CO2 and H2S, salt-free) and the water dew point at the discharge; ISO 15156-2 Figure 1 region and the material check are for the materials group.
- Adding a trace component to a model fluid: check the unit operations that rebuild streams by component index (a
ComponentSplitterwith split factors[1]*(n-1)+[0]
removes the LAST component); insert the tracer before the last component and verify the downstream ppm is not zero.
Network-Level Corrosion (LoopedPipeNetwork)
For production gathering networks, LoopedPipeNetwork has inline corrosion
models that compute rates per element during network solution:
// de Waard-Milliams (default) or NORSOK M-506
net.setCorrosiveGas("trunk", 0.035, 0.002); // CO2 mol%, H2S mol%
net.setCorrosionModel("trunk", "NORSOK"); // "DEWAARD" or "NORSOK"
net.setMinAllowableWallLife(20.0); // years
net.run();
Map<String, double[]> corr = net.calculateCorrosion();
// Per element: [0] = rate (mm/yr), [1] = pCO2 (bar), [2] = wall life (yr)
List<String> violations = net.getCorrosionViolations();
Models: de Waard-Milliams (log10(Vcorr) = 5.8 - 1710/T + 0.67*log10(pCO2))
and NORSOK M-506 (Vcorr = Kt * fCO2^0.62 * (S/19)^0.146).
Legacy CO2 corrosion screening from a brine (electrolyte pH + FeCO3 film)
NorsokM506CorrosionRate (neqsim.process.corrosion) uses de Waard-Milliams screening equations (fugacity, in-situ pH, FeCO3 scaling temperature, wall shear, glycol,
inhibitor). By default it estimates pH from a CO2-water correlation. To drive it
from rigorous electrolyte thermodynamics instead, use NorsokM506ElectrolyteBridge
— the M-506 analogue of CO2CorrosionAnalyzer:
// fluid = SystemElectrolyteCPAstatoil with CO2, water, ions (+ optional Fe++)
NorsokM506ElectrolyteBridge bridge = new NorsokM506ElectrolyteBridge(fluid);
bridge.setFlowVelocityMs(3.0);
bridge.setPipeDiameterM(0.254);
bridge.run(); // clones + flashes; does not mutate `fluid`
double rate = bridge.getModel().getCorrectedCorrosionRate(); // mm/yr
double pH = bridge.getInSituPH(); // rigorous aqueous pH (getpH())
double sr = bridge.getFeCO3SaturationRatio(); // IAP/Ksp, or -1 if no Fe++/CO3--
boolean suspect = bridge.isElectrolytePhaseSuspect(); // true -> correlation pH was used
Gotcha (2026-11-22): the electrolyte CPA pH of CO2-saturated water is about 0.9 units high
(4.84 vs about 3.9 at 25 C, 1 bar CO2), which gives non-conservative rates. The bridge falls back to
the correlation pH when the aqueous phase is suspect (water < 0.7 mol frac) or pH is outside 2.5-10;
check isElectrolytePhaseSuspect() and compare with the correlation pH. ChlorideSCCAssessment
reports carbon and low-alloy steels as "Not susceptible" (they used to fall through to 316L).
FeCO3 film feedback (closes the corrosion↔scaling loop): when the aqueous phase
is supersaturated in siderite (SR>1), a protective film suppresses corrosion even
below the scaling temperature. Supply the ratio directly on the model, or let the
bridge compute it from aqueous Fe++/CO3-- molalities (Sun & Nesic 2009 Ksp):
model.setFeCO3SaturationRatio(sr); // >1 = protective; -1 = disabled (default)
double film = model.calculateFeCO3FilmFactor(); // 1.0 = no credit, <1 = protective
For an auditable legacy screening calculation, pass the resulting in-situ pH and optional saturation ratio
to NorsokM506CorrosionDesignKernel.Input. For the M-506 Rev. 2 unmitigated rate, use NorsokM506Rev2.rateMmPerYear with
local shear and in-situ pH. The legacy kernel checks its registered 2017 edition identifier and model envelope, preserves raw inputs
without setter clamping, and returns CALCULATED_REVIEW_REQUIRED. Continue to use the bridge to
derive chemistry and the legacy model for sweeps, but do not present either route as a conformity
assessment. The optional saturation-ratio film factor and projected wall loss are NeqSim screening
extensions, not code acceptance criteria.
Gotchas (verified): SystemInterface.clone() drops the chemical-reaction setup
— re-run chemicalReactionInit() on the clone before flashing or the CO2-brine pH
comes out unphysically basic (~10). setActualPH() is read back via getEffectivePH(),
NOT getCalculatedPH(). Proven converging brine: CO2 0.10 / water 0.88 / Na+ 0.01 /
Cl- 0.01, setMixingRule(10).
Robust in-situ pH for investigations
getpH() on the aqueous phase (or SystemInterface.getpH()) returns the in-situ
pH. It now has a built-in acid-gas dissociation fallback: when the aqueous
phase has water + dissolved CO2/H2S but no explicit H3O+ species (i.e.
chemicalReactionInit() was not run) or the electrolyte solver is unstable and
returns NaN at low pressure, getpH() estimates pH from the carbonic/sulfide
acid first-dissociation equilibria — [H+]=sqrt(K1_CO2·C_CO2 + K1_H2S·C_H2S + Kw)
— instead of the old silent, unphysical 7.0. CO2-saturated water → pH ≈ 3.9.
Force it explicitly with getpH("acidgas"). This is a screening estimate
(ignores bicarbonate buffering and salt-ion alkalinity); for a rigorous speciated
pH in a buffered brine still run chemicalReactionInit().
For corrosion/scale investigations that must always return a finite, bounded,
source-tagged value with an explicit pCO2 basis, use
RobustAqueousPH.estimate(fluid, pCO2Bar): it takes the rigorous getpH() when
valid, else a CO2-water correlation, and records which source was used
(getSource(), isFellBack()).
Regression test for the fallback: neqsim.chemicalreactions.AcidGasPHTest
(CO2-saturated water pH ≈ 3.9, neutral water ≈ 7, CO2+H2S acidic — all without
chemicalReactionInit()).
Per-segment corrosion + scale along a line (PipeSegmentIntegrity)
PipeSegmentIntegrity (neqsim.process.corrosion) walks a temperature/pressure/
velocity profile and reports, per segment, the legacy screening corrosion rate AND the
CaCO3 scale saturation, then ranks the worst corrosion and worst scale segments —
so mitigation can be located along the line. Feed it a run PipeBeggsAndBrills:
PipeSegmentIntegrity integrity = new PipeSegmentIntegrity();
integrity.fromPipe(pipe) // extracts T, P, mixture velocity, diameter
.setPipeAndGas(0.2, 0.05) // diameter [m], CO2 mole fraction
.setBrineChemistry(1500, 400, 0, 0, 12000, 35000); // Ca,HCO3,SO4,Ba,Na,Cl [mg/L]
integrity.evaluate();
int worstCorr = integrity.getWorstCorrosionIndex();
int worstScale = integrity.getWorstScaleIndex();
// or supply an explicit profile: integrity.setProfile(tC[], pBara[], vMs[])
Network-Level Sand Erosion (DNV RP O501)
net.setSandRate("W1", 3.0); // kg/hr
net.setMaxAllowableSandRate(10.0);
net.setMaxAllowableErosionRate(5.0); // mm/yr
net.run();
Map<String, double[]> sand = net.calculateSandTransport();
// Per element: [0] = rate, [1] = concentration, [2] = erosion, [3] = deposition
List<String> violations = net.getSandViolations();
Erosion per DNV RP O501: E = K * Csand * v^2.6 * dp^0.2.
Deposition flagged when v < 1 m/s.
Sand TRANSPORT is a different question from sand EROSION
Erosion asks "is the fluid too fast?"; transport asks "is the fluid fast enough
to keep the sand moving?". They pull in opposite directions, so a line can
be comfortably inside its erosional limit and still be laying down a sand bed.
NeqSim currently models erosion only (ErosionPredictionCalculator,
LoopedPipeNetwork.calculateSandTransport()), and the network deposition rule
above is a hard-coded v < 1 m/s, not a transport criterion. Compute the
transport check explicitly.
**Evaluate transport on the in-situ LIQUID velocity, never on the mixture
velocity.** Sand is carried by the liquid, and because of slip
u_L = v_sl / H_L (in-situ liquid velocity)
u_G = v_sg / (1 - H_L) (in-situ gas velocity)
H_L > lambda_L whenever there is slip, so u_L < v_m. On a measured mature-well
case (6" line, 52% water cut, ~45 bara) v_m was 0.888 m/s but u_L only
0.691 m/s — using v_m would have overstated the transport margin by 1.29x.
Two criteria, both public and cheap:
- Oroskar & Turian (1980) critical (deposition) velocity —
v_c = 1.85 C^0.1536 (1-C)^0.3564 (D/d_p)^0.378 Re_p^0.09 x^0.30 sqrt(g d_p (s-1))
with Re_p = D sqrt(g d_p (s-1)) rho_L / mu_L and x ~ 0.95. Report u_L / v_c.
- Shields (1936) incipient motion of a settled bed — compare the liquid wall
shear tau_w = (f/8) rho_L u_L^2 to tau_c = theta_c (rho_s - rho_L) g d_p
with theta_c ~ 0.045.
Sand deposition is a TURNDOWN failure mode. As rate falls, hold-up rises and
the slip ratio grows, so u_L collapses faster than v_m. Always run a rate
sweep and report the rate at which u_L crosses v_c — that threshold, not the
present-day margin, is the number operations needs. Do not use erosion headroom
as a reason to choke a well back without checking it.
Minimum flow of a tie-back line, on the real route
A line is not "flat plus a riser" once it is longer than about 2 km, and one rate is not a design.
- Use the real profile. Take depths along the route (survey, EMODnet
depth_sample, or the
KP route of an existing line) and build
RouteProfile.fromDepths(kp, depth).withRiser(depthAtHost, airGap).resample(60), then
route.applyTo(twoFluidPipe); route.getLowPointKp() lists the liquid traps.
route.applyTo(PipeBeggsAndBrills) collapses the route to one averaged leg and logs a warning above
5 degrees; it keeps the net rise and loses the undulation. Compare the real profile with a flat
bed of the same length and riser on the SAME model before saying the seabed does not matter.
- Fix the outlet, solve the inlet.
TwoFluidPipe.setOutletPressure(p, "bara")gives the inlet
pressure the line needs, which is the number a VFP or nodal curve wants. Fixing the inlet and
reading the outlet hides how fast the line pressure runs away at low rate.
- Sweep the rate downwards (about 10 to 200 % of plateau, with and without lift gas, at the lowest and
highest water cut) and report each limit by name; the minimum flow is the largest of them:
- hydraulic: the rate where the required inlet pressure stops falling (U-shape: friction falls,
hold-up and hydrostatic head rise);
- hold-up and liquid inventory (
getLiquidInventory("m3"),getLiquidHoldupProfile()) and the
time to sweep it after a restart;
- thermal: arrival temperature minus the hydrate or wax temperature at the line pressure;
- sand or solids:
u_L / v_c(section above); - riser or terrain slugging and the pig rate, which the steady-state model does not give.
- Always check
isSteadyStateConverged()and the iteration count; a case that exits after one
sweep is not a solution.
- State what was not run: severe-slugging limit cycles need a transient run and are not qualified in
TwoFluidPipe (see the evidence matrix); a steady-state hold-up profile is not a slug size.
Get the operating basis right before computing any velocity
A wrong pressure invalidates every velocity, hold-up and transport number
downstream of it, and no amount of model sophistication recovers it.
A well flowline runs DOWNSTREAM of the choke. Its pressure is the receiving
manifold/separator pressure, not the wellhead pressure that PDM and the
historian report as "wellhead pressure" / "brønnhodetrykk". On a real case the
wellhead read 45.5 bara while the line ran at 17.0 bara: gas density 63% lower,
mixture velocity 2.1x higher, no-slip hold-up 59% lower, and the sand-transport
margin moved from 1.38 to 1.8-2.3. Take the flowline condition from the
after-choke transmitter (Norwegian tag descriptions: "Etter Strupeventil").
Confirm which route is actually in use, not just which routes exist. Match
the measured after-choke pressure against the separator pressures; the receiving
vessel is the one a small dP away, and the others are typically tens of bar off.
Check the trend as well as the snapshot — a well swaps onto the test separator
during a well test, which is usually a higher pressure and therefore the
binding case for sand deposition, while normal production is comfortable.
Derive the line temperature by an isenthalpic flash across the choke when
there is no after-choke temperature transmitter (ops.PHflash(h_wellhead)). With
a high water cut the JT cooling is small (~1 K at 83 mol% water) because water
dominates the heat capacity — do not assume a large drop.
Choosing the multiphase model for a transport check
Start with the
It separates implemented, numerically verified, experimentally qualified, failed,
and unsupported configurations. Do not route from a finite profile or a private
commercial-simulator comparison.
- Use
PipeBeggsAndBrillsfor a correlation-based steady or quasi-steady
pressure-drop screen. It has no conservative distributed line-pack inventory,
so it is not evidence for transient liquid accumulation or severe slugging.
- Use
TwoFluidPipewhen section-resolved phase momentum, holdup, inventory,
thermal, or transient diagnostics are required and the requested
configuration fits a verified matrix row.
- The public Mohmmed air/water slug comparison currently fails qualification:
the baseline passes 3/9 fixed gates with MARE 1.0402, and the 40/80-cell plus
0.05/0.025 s sweep is non-monotone. Do not replace that evidence with a looser
physical bound or a proprietary trace.
- Gate every steady result on the complete convergence report and every transient
on requested elapsed time, conservation, positivity, refinement, and all
applicable sticky solver/boundary diagnostics. Exclude a failed or unsupported
row instead of quoting it.
- The experimental unsplit directional-complementarity path now solves nonnegative
mass magnitude, advective momentum and donor multipliers for both one-sided donor streams
and verifies its solved ledger independently. Physical AUSM transport and pressure
correction retain separate donors. Conflict-free exact-presence anchors and exact
zero-flow rows permit phase-free multi-cell regions without a mass clip or inventory
tolerance. Treat disappearance, simultaneous opposing streams and short-step
conservation tests as numerical evidence only: all no-pressure-interpolation
five-second lanes complete, but pressure-interpolated baseline and augmented lanes
still stop at 1.075--1.8427734375 s, so the complete riser matrix remains failed.
Require that entire matrix before progressing to 180/600 s,
physical restart, swept-liquid, receiver-surge or hydraulic-pigging claims.
- The current no-pressure-interpolation unsplit preparer advances passive wall
and interphase friction once with the conservative frozen-resistance source.
Audit the accepted per-cell phase impulse from PreparedStep/PreparedInterval.
The three midpoint five-second lanes now pass; the pressure-interpolated lanes
still stop at 1.4000/1.8125/0.9750 s and retain their prior friction owner
because the combined operator regresses the trace-phase/donor event. This is
numerical source evidence only, not restart, severe-slugging or pigging
qualification.
- For the bounded frozen-phase
runTransientroute, configure
setOutletBoundaryFluid(...) whenever a constant-pressure outlet can donate a
reversed phase. The signed transfer stays in the phase ledger; only positive
exports enter the downstream stream. The historical-grid 16/24-cell,
0.1/0.05 s five-second matrix and the 16-cell 180/600 s duration gates pass
with backward Euler, pressure interpolation, transition blending and signed
donor transport. The interval controller tightens local solves against a
duration-weighted share of the unchanged cumulative conservation budget.
Treat this as atomic numerical continuation evidence, not experimental severe
slugging, physical restart, receiver surge or pigging qualification.
- Do not over-constrain
setOutletPressurewith a measured pressure drop the
modelled geometry cannot produce. Investigate valves, fittings, elevations, and
boundary consistency separately.
Mineral Scale (thermodynamics + kinetics + brine mixing)
For commingled formation waters with dissolved silica, follow the
with the NeqSim and PHREEQC Pitzer example. Compare the CO₂ boundary conditions
and amorphous silica, crystalline silica and metal silicate results at each station.
For common carbonate and sulfate minerals, pick by how much you know about
the brine and whether you need a rigorous precipitated amount.
(A) Screening SI from an ion analysis (fast, no flash). Activity-corrected
saturation index (Davies + Ksp(T)) for the common scales directly from a
produced-water ion table in mg/L:
ElectrolyteScaleCalculator scale = new ElectrolyteScaleCalculator();
scale.setTemperatureCelsius(60).setPressureBara(100).setPH(6.0);
scale.setCations(caMgL, baMgL, srMgL, mgMgL, naMgL, kMgL, feMgL);
scale.setAnions(clMgL, so4MgL, hco3MgL, co3MgL);
scale.calculate();
double siCaCO3 = scale.getCaCO3SaturationIndex(); // also BaSO4, CaSO4, SrSO4
// SI = log10(IAP/Ksp): >0 supersaturated (scale risk), 0 at equilibrium, <0 undersaturated
**(B) Rigorous scale potential from a speciated electrolyte fluid — REQUIRES
chemical reactions + speciation.** The rigorous saturation ratio needs the *in
situ* ion molalities (Ca²⁺, HCO₃⁻, CO₃²⁻, Ba²⁺, SO₄²⁻, …), which only exist
after the aqueous speciation equilibria have been solved. So you MUST call
chemicalReactionInit() before createDatabase(true) / setMixingRule(10), and
you should get the in-situ pH from the same speciated flash (see the in-situ pH
section above). Then checkScalePotential(phaseNumber) returns, per salt, the
saturation ratio SR = IAP/Ksp ("relative solubility"): SR > 1 means
supersaturated and at scale risk.
SystemInterface brine = new SystemElectrolyteCPAstatoil(273.15 + 60.0, 100.0);
brine.addComponent("CO2", 0.02);
brine.addComponent("water", 55.5);
brine.addComponent("Na+", 1.0);
brine.addComponent("Cl-", 1.0);
brine.addComponent("Ca++", 0.02);
brine.addComponent("HCO3-", 0.04);
brine.chemicalReactionInit(); // MANDATORY: builds carbonate/bicarbonate speciation
brine.createDatabase(true);
brine.setMixingRule(10); // numeric CPA rule (required)
brine.setMultiPhaseCheck(true); // allow gas + aqueous (+ solid) phases
ThermodynamicOperations ops = new ThermodynamicOperations(brine);
ops.TPflash(); // solves speciation in the aqueous phase
brine.initProperties();
int aq = brine.getPhaseNumberOfPhase("aqueous");
ops.checkScalePotential(aq); // uses speciated ion molalities in phase `aq`
String[][] sr = ops.getResultTable(); // rows: {saltName, SR (=IAP/Ksp), ""}
// Read SR per salt; SR > 1.0 => supersaturated => scale precipitation likely.
double pH = brine.getpH(); // rigorous speciated in-situ pH from the same flash
Convenience equipment wrapper: ScalePotentialCheckStream runs the same SR
check on a process Stream.
Precipitation amount (how much solid forms). Two options:
- Rigorous (solid phase flash): with
setMultiPhaseCheck(true), a
supersaturated brine drops a solid phase during TPflash(). Read the
precipitated mineral directly:
```java
if (brine.hasPhaseType("solid")) {
double solidMoles = brine.getPhase("solid").getNumberOfMolesInPhase();
double solidMassKg = solidMoles * brine.getPhase("solid").getMolarMass();
}
```
- Screening (from SI):
ScaleMassCalculatorestimates the mg/L precipitated to
reach equilibrium from ion concentrations and SI (per mineral):
```java
ScaleMassCalculator mass = new ScaleMassCalculator(predictionCalc);
mass.setWaterVolume(1.0); // litres
double caco3MgL = mass.calcCaCO3Mass(cCaMolL, cCO3MolL, siCaCO3); // mg/L
// also calcBaSO4Mass, calcCaSO4Mass, calcSrSO4Mass, calcFeCO3Mass
```
⚠️ ScaleMassCalculator is decoupled — each mineral is treated
independently, so it overpredicts competing minerals (e.g. it reports
celestite scaling even when barite has already consumed the shared sulphate).
- Coupled screening (recommended for shared-ion brines):
MultiMineralScaleEquilibrium drops all supersaturated minerals
simultaneously and re-equilibrates the shared ion pools (sulphate: BaSO4 /
SrSO4 / CaSO4; carbonate: CaCO3 / FeCO3; calcium shared by anhydrite and
calcite), giving OLI/ScaleChem-style precipitated amounts plus the residual
brine. It reuses the same Ksp/ion-pairing/activity chemistry as
ScalePredictionCalculator, and can upgrade the activity model from Davies
(I ≤ 0.5 m) to an extended B-dot (Helgeson) model for high-salinity brines:
```java
MultiMineralScaleEquilibrium eq = new MultiMineralScaleEquilibrium(predictionCalc)
.setActivityModel(MultiMineralScaleEquilibrium.ActivityModel.BDOT) // high-I option
.setWaterVolume(1.0);
eq.solve();
double baso4MgL = eq.getPrecipitatedMassMgPerL("BaSO4");
double totalMgL = eq.getTotalScaleMassMgPerL();
double srResid = eq.getResidualFreeIonMolPerL("SO4--");
// each precipitated mineral ends at SI≈0; suppressed minerals stay SI≤0
```
For high-pressure brines, enable the second-order (compressibility) Ksp term on
the predictor first: predictionCalc.setSecondOrderPressureCorrection(true).
- In a process flowsheet (scaling mass RATE):
StreamScaleAnalyzerextracts the
aqueous ion chemistry + produced-water throughput from a run Stream and turns
the coupled equilibrium into a kg/day scaling rate — the number that matters
for operations and deposition:
```java
StreamScaleAnalyzer a = StreamScaleAnalyzer.fromStream(producedWaterStream);
a.analyze();
double bariteKgPerDay = a.getScaleRateKgPerDay("BaSO4");
double totalKgPerDay = a.getTotalScaleRateKgPerDay();
String dominant = a.getDominantScale();
```
(Needs an electrolyte-CPA fluid with an aqueous ion phase; a non-electrolyte
stream carries no ions and reports no scale.)
- Root cause analysis:
RootCauseAnalyser.setWaterChemistryFromStream(stream)
(or the ion setters) makes a scale-deposit symptom self-quantifying — the
MINERAL_SCALE candidate then carries the coupled dominant mineral and its
predicted mg/L, and is down-weighted when the brine is thermodynamically
undersaturated (deposit is more likely wax/asphaltene/corrosion product).
- Agentic (MCP): the
runChemistrytool exposesanalysis:"multiMineralScale"
(ions in mg/L + T/P + optional waterFlow_LPerDay, activityModel:"BDOT",
secondOrderPressure) returning per-mineral amounts and a kg/day rate.
Model validation: the Ksp correlations are pinned to published log10(Ksp)
at 25 °C in
ScaleKspLiteratureBenchmarkTest— calcite −8.48, barite −9.97,
celestite −6.63, anhydrite −4.36, siderite −10.89 (Greenberg & Tomson 1992).
Keep the siderite form
-59.3498 - 0.041377*T - 2.1963/T + 24.5724*log10(T)
consistent across
ScalePredictionCalculator,CheckScalePotentialand
CalcSaltSatauration(noT^2term).
Kinetics — SI says if, not how fast. ScaleKinetics adds induction time
and growth regime on top of the SI:
ScaleKinetics k = new ScaleKinetics().setSaturationIndex(si).evaluate();
double tInd = k.getInductionTimeHours(); // classical nucleation
String regime = k.getLimitingRegime(); // REACTION / TRANSPORT / NONE
double growth = k.getEffectiveGrowthRateMmYr();
Brine mixing (seawater + formation water incompatibility) — sulphate scale
often peaks at an intermediate mixing ratio, not either end member:
BrineMixingScaleEvaluator mix = new BrineMixingScaleEvaluator(formationWater, seawater);
mix.setConditions(60, 100).setPH(6.0).setSteps(21).evaluate();
double worstFrac = mix.getWorstFractionA(); // fraction of formation water
String worst = mix.getWorstMineral(); // e.g. BaSO4
Deposition along a line: ScaleDepositionAccumulator (walks a PipeBeggsAndBrills),
or the coupled corrosion+scale PipeSegmentIntegrity above.
Valve scale drift (plugging → Cv loss → opening drift → RCA)
Scale/solids on a control-valve trim do not fail the valve suddenly: the deposit
shrinks the open flow area, the effective Kv/Cv drops, and the level/pressure
controller opens the valve further to hold setpoint — an observable upward
drift of the opening until it pins at 100% and control is lost. This is the
classic level-valve-plugging signature. ThrottlingValve now carries a fouling
term and ValveScaleDrift turns a deposit growth rate into that drift:
valve.setFoulingFraction(0.5); // effectiveKv = Kv*(1-f); 0=clean
double effCv = valve.getEffectiveCv();
ValveScaleDrift drift = new ValveScaleDrift(valve)
.setPortDiameter(0.05) // trim port diameter [m]
.setKinetics(scaleKinetics); // or setGrowthRateMmPerYear(20.0)
for (int day = 0; day < 60; day++) {
drift.advance(1.0); // grow deposit, update valve foulingFraction
process.run(); // controller compensates -> opening drifts up
}
double daysToPin = drift.predictTimeToPinDays(cleanOpeningPercent); // loss of control
double tPlug = drift.getTimeToPlugDays(); // full closure
Uniform radial deposit model: foulingFraction = 1 - ((d0 - 2t)/d0)^2; the
opening required to hold flow rises as cleanOpening / (1 - fouling). Use it in
an RCA to reproduce the "both LVs → 100% open, level still rising, no inflow
surge" trend and to bound time-to-plug.
Scale / precipitation remediation (dissolvers & washing for RCA solutions)
Once a deposit is identified, ScaleRemediationAdvisor recommends the dissolver /
solvent / wash to clean the already-fouled equipment (valves, trim, bridles,
lines, exchangers) — the proposed-solution counterpart to inhibitor prevention.
It is backed by a knowledge-base CSV (/data/scale_remediation.csv) and maps
common mineral names to canonical formulae:
ScaleRemediationAdvisor advisor = new ScaleRemediationAdvisor();
List<ScaleRemediationAdvisor.RemediationOption> opts = advisor.recommendFor("calcite");
ScaleRemediationAdvisor.RemediationOption best = opts.get(0); // ordered by effectiveness
best.getDissolver(); // e.g. "Hydrochloric acid (HCl) with corrosion inhibitor ..."
best.getMethod(); // "Acid soak or circulation, then neutralise and flush"
best.getCautions(); // safety/operational cautions
String json = advisor.toJson("BaSO4");
Coverage & the key gotcha it encodes: **acid dissolves carbonate/sulfide scale
(CaCO3, FeCO3, FeS) but NOT sulfate scale** — barite/celestite (BaSO4, SrSO4)
need a high-pH chelant (DTPA/EDTA); dithiazine (H2S-scavenger solids) needs a
proprietary dissolver plus restoring water pH control to prevent recurrence;
asphaltene/wax/naphthenate use aromatic solvent / hot oil. Unknown deposits
return a "sample-and-identify first (XRD/SEM-EDX)" guard.
RootCauseAnalyser uses this automatically: every deposit candidate
(MINERAL_SCALE, WAX_DEPOSITION, ASPHALTENE, FES_DEPOSITION) now appends a
concrete "to clean fouled equipment: <dissolver> …" hint to its recommendation,
targeting the coupled dominant mineral when ion chemistry is available.
Deposits on compressors (fouling → performance loss → washing)
When deposit-forming species (elemental sulfur S8, salt from entrained produced
water, mineral scale, wax) reach a compressor, they foul the impeller and reduce
head/efficiency. The neqsim.process.equipment.compressor deposit model bridges
these flow-assurance calculations to compressor performance and washing:
CompressorDeposit dep = CompressorDeposit.fromCompressor(comp);
dep.accumulate(new SolidFlashDepositSource(feed, "S8", DepositMechanism.SULFUR_S8, 0.3), 500.0);
dep.accumulate(new EntrainedSaltDepositSource(10.0, 0.05), 500.0); // entrained brine -> salt
comp.setDepositModel(dep); // run() degrades efficiency/power
CompressorChart chart500 = comp.buildDegradedChart(); // map after 500 h
WashFluid wash = CompressorDepositWash.recommend(dep); // salt->WATER, S8->XYLENE
comp.washOnline(wash, 300.0, 3.0); // online wash removes matching deposits
Per-impeller deposit location: CompressorDepositProfile.compute(...) /
computeFromPropertyProfile(...). Full API in the neqsim-api-patterns skill and the
compressor_deposit_degradation doc. Use this to plan sulfur/salt washing of fouled
compressors and to recommend a wash fluid.
6. Thermal Analysis
Cooldown Calculation
// Simple cooldown time estimate for insulated pipeline
// Use Newton's cooling law: T(t) = Tsea + (Tin - Tsea) * exp(-t/tau)
// where tau = m * Cp / (U * A)
// U = overall heat transfer coefficient (W/m2K)
// A = pipe surface area per unit length (m2/m)
// m = fluid mass per unit length (kg/m)
// Cp = fluid heat capacity (J/kgK)
Burial, trenching and rock dump change the thermal basis
A buried or rock-covered flowline cools down much more slowly than an exposed one, so one burial depth
for the whole line is wrong wherever the route changes between trenched, rock-covered and exposed
stretches. Scope the protection first with the neqsim-seabed-protection-screening skill (map layers,
trenchability, rock volume and tonnes; community seabed-protection-agent), then use its
to_neqsim_burial_segments hand-off: one pipe section per burial state with setBuried,
setBurialDepth (depth to the pipe centre) and setSoilConductivity, exposed sections on the
seawater film coefficient. Report cooldown and hydrate margin for the protected and the unprotected
state so the margin that burial buys is explicit. Burial depth and soil conductivity are thermal
inputs only - never derive pipe-soil resistance or upheaval-buckling cover from them (see the DNV-RP-F114
and F110 routing above).
Arrival Temperature Check
// Critical checks:
// 1. Arrival T > hydrate formation T + margin (typically 5°C subcooling)
// 2. Arrival T > WAT (if waxy crude) + margin
// 3. Arrival T > pour point (for restart)
// If not met: increase insulation, add DEH, reduce flow, or inject inhibitor
Low-rate satellite tie-back: heat loss, not friction, sets the design
A short tie-back at 0.5-2 kSm3/d liquid (typical of a small cold, shallow oil such as the Barents
satellites) has a pressure drop of 1-2 bar in 6-8 in, but a residence time of about a day, so the
arrival temperature falls towards the seabed. Rank the options on arrival temperature and cost, not
on hydraulics:
- Run
PipeBeggsAndBrillswithsetUseOverallHeatTransferCoefficient(true)and U = 12 (bare),
4 (wet insulation), 2.5 (thick wet), 1.2 W/m2K (pipe-in-pipe) at 500-4000 Sm3/d, at the real
wellhead temperature (area BHT trend gives the reservoir temperature when no BHT is reported).
- No-touch time must include the steel (and half the insulation) heat capacity per metre; the fluid
alone overstates the cooling rate by about 50 %.
- The WAT is usually the unknown: sweep it (for example 18 / 26 / 34 C) instead of picking one; a
passive 12 h no-touch time to a 26 C WAT from 35 C is not reachable even with pipe-in-pipe, so
adopt displacement/flush and chemicals for restart, keep DEH as the hedge for a high WAT, and say
that WAT, pour point and viscosity are the first data need.
- Rank options by 15-year life-cycle cost (capex premium + chemical opex) and list the measured-WAT
decision rule (low WAT: wet insulation; mid: wet insulation plus displacement; high: DEH or PiP or
avoid a new line, for example by extended-reach wells from an existing template).
### DEH operations: how much power, how much temperature, how much energy
Use this when a task asks what a direct-electrical-heating (DEH) system or an inlet heater is worth,
how much electricity it burns or how its on/off operation relates to arrival temperature. The
detailed pipe model is `setDirectElectricalHeatingPower` (above); for yearly screening a lumped
model is enough and is cheap enough for Monte Carlo.
- **Lumped arrival temperature** with distributed DEH power $P$: balance temperature
$T_{bal}=T_{sea}+P/UA$, arrival $T=T_{bal}+(T_{in}-T_{bal})e^{-UA/\dot m c_p}$. Fraction of DEH heat
that reaches the arrival (heat-exchanger effectiveness) is $\eta=(1-e^{-NTU})/NTU$ with
$NTU=UA/\dot m c_p$, so it falls from about 0.55 at 9 MSm3/d to about 0.2 at 2.5 MSm3/d in a
30 km line: electric DEH loses most of its heat to the sea at low rate, a heater at the receiving
end does not. Take $\dot m c_p$ from NeqSim (recombined wellstream, TP flash, per MSm3/d), not
from gas alone: liquids and water add 5-15 %.
- **Calibrate on two independent anchors** (flow-assurance rate-vs-arrival-temperature curve and a
measured DEH step test), fit $(T_{in},UA)$ on one and predict the other; cap $T_{in}$ at a
physical wellhead temperature or the pair is degenerate (T_in runs to the optimiser bound).
- **Never read DEH power from the transformer tap tag.** The tap/step tag is a setting that stays
at its last value (for example 12.6 of 13) with the breaker open. Power is breaker state times
primary current: $P\approx P_{max}\,I/I_{max}$ (check median current when on against the rated
power to find $I_{ref}$). One field showed the breaker closed 25 % of hours at about 7.7 MW,
so the time-average power was 2.0 MW (17 GWh/y), not the 7.7 MW the tap tag suggests, and a
quoted "halve the DEH, save 20 kt CO2" only applies once DEH runs continuously.
- **Bang-bang DEH** (fixed power steps, on/off) holds the mean temperature but not the minimum.
Report on-fraction per month and the temperature percentiles, not only the mean; a regulated
heater saves little energy at equal mean but narrows the band, so value it through the
threshold-driven consequence (for example oil-in-water exceedance probability vs temperature
bin), not through kWh.
- **Cross-check hydrate margin in the heated line**, not only at the receiving separator: the
arrival temperature without DEH crosses (hydrate formation temperature + margin) years before the
separator temperature does. In Python, `hydrateFormationTemperature()` on a CPA fluid with a long
component list threw `getPhase ... Can not return` here; `runFlowAssurance` `hydrateRiskMap` (MCP)
returned the CPA temperature directly and is the quick route.
- Calibrate unknown mixing inputs (temperature of the other streams, DEH delivery scale) by
approximate Bayesian rejection against the measured energy rather than fixing them: draw from
wide priors, keep draws that reproduce the measured average DEH energy, and carry the survivors
through the economics.
## 7. Flow Assurance Decision Matrix
| Threat | Detection | NeqSim Method | Mitigation |
|--------|-----------|---------------|------------|
| Hydrate | `hydrateFormationTemperature()` | CPA EOS + hydrate check | MEG, methanol, insulation, DEH |
| Wax | `calcWAT()`, `WaxFractionSim` | Wax characterization | Pigging, inhibitor, insulation |
| Asphaltene | de Boer screening | `AsphalteneSolidModel` calibrated to a measured onset; CPA flash at multiple P | Inhibitor, avoid P drop |
| Naphthenate / soap | `NaphthenatePrecipitationModel` with default parameters (onset pH, risk class) | Same model with parameters regressed by `NaphthenateModelFitting` to bottle tests | Keep pH low (acid, CO2 back-pressure), naphthenate inhibitor |
| Corrosion (CO2) | CO2 partial pressure | Standard flash | CRA, inhibitor, pH stabilization |
| Slugging | Beggs & Brill flow regime | `PipeBeggsAndBrills` | Slug catcher, topside choking |
| Scale | Ion activity product | Electrolyte-CPA | Scale inhibitor, pH control |
| Elemental sulfur (S8) | S8 solid drop-out at P/T letdown | `setSolidPhaseCheck("S8")` + `TPSolidflash()` | Remove O2 source, heat gas before letdown, reduce dP, `SulfurFilter` |
## 8. CO2 Injection Well Analysis
For CCS/injection well safety analysis, use the dedicated analyzer:
CO2InjectionWellAnalyzer analyzer = new CO2InjectionWellAnalyzer("InjWell-1");
analyzer.setFluid(co2Fluid);
analyzer.setWellGeometry(measuredDepth, innerDiameter, roughness);
analyzer.setOperatingConditions(inletP_bara, inletT_C, massFlowRate_kg_h);
analyzer.setFormationTemperature(surfaceT_C, bottomholeT_C);
analyzer.addTrackedComponent("hydrogen", maxMolFracLimit);
analyzer.runFullAnalysis();
boolean safe = analyzer.isSafeToOperate();
### Impurity Monitoring
ImpurityMonitor monitor = new ImpurityMonitor("H2-Mon", stream);
monitor.addTrackedComponent("hydrogen", 0.10); // 10 mol% limit
monitor.addTrackedComponent("H2S", 0.001); // 0.1% limit
double enrichment = monitor.getEnrichmentFactor("hydrogen");
boolean exceeds = monitor.exceedsLimit("hydrogen");
## 9. Elemental Sulfur (S8) Deposition
Elemental sulfur (cyclo-octasulfur, `S8`) drops out of natural gas as a yellow/grey
solid at points of pressure and/or temperature letdown — compressor inlets, control
and letdown valves, dry-gas seals, pressure regulators, and filters. The gas dissolves
a small amount of S8 (solubility rises with pressure and with H2S/CO2 content, and is
high in condensate, MEG, methanol and TEG); when pressure or temperature drops, the
gas becomes supersaturated and S8 deposits. The **root cause is almost always an
oxygen source** oxidising H2S: `8 H2S + 4 O2 -> S8 + 8 H2O` (O2 typically enters via
preservation fluids, platform-nitrogen purge/seal gas, or injected chemicals).
**Screening workflow:** assume the gas is S8-saturated at a baseline (e.g. scrubber /
separator conditions such as 100 bara, 45 C), then check whether S8 drops to a solid
as the stream follows the compressor / valve pressure-temperature path. `S8` is a
database component (`fluid.addComponent("S8", ...)`), and deposition is detected with a
solid flash.
### S8 solid-drop-out (solubility) check
// Gas saturated with a trace of S8 at baseline, then evaluate a P/T letdown point
SystemInterface fluid = new SystemSrkEos(273.15 + 45.0, 100.0);
fluid.addComponent("methane", 0.90);
fluid.addComponent("CO2", 0.02);
fluid.addComponent("H2S", 0.001);
fluid.addComponent("S8", 1.0e-6); // trace S8 (mole basis)
fluid.setMixingRule("classic");
fluid.setMultiPhaseCheck(true);
fluid.setSolidPhaseCheck("S8"); // enable S8 solid-phase modelling
// Evaluate at the letdown condition (e.g. valve / compressor-inlet P and T)
fluid.setPressure(60.0, "bara");
fluid.setTemperature(30.0, "C");
ThermodynamicOperations ops = new ThermodynamicOperations(fluid);
ops.TPSolidflash(); // NOT TPflash — needed to form the solid S8 phase
fluid.initProperties();
boolean s8Deposits = fluid.hasPhaseType(PhaseType.SOLID);
if (s8Deposits) {
double solidMass = fluid.getPhaseOfType("solid").getMass("kg"); // S8 solid inventory
}
> Rule of thumb: deposition risk exists wherever a saturated (or nearly saturated)
> stream sees a pressure or temperature drop. Heating the gas *before* letdown or
> reducing the dP moves the point back into the single-phase (dissolved) region.
### SulfurFilter equipment (solid S8 removal + change interval)
`SulfurFilter` runs a `TPSolidflash` internally, removes the solid S8, and tracks the
kg/hr loading for element sizing and change-out interval:
SulfurFilter filter = new SulfurFilter("S8 Filter", valveOutletStream);
filter.setRemovalEfficiency(0.99); // 99% solid removal
filter.setFilterElementCapacity(50.0); // kg S8 per element set
filter.setDeltaP(0.5); // clean pressure drop [bar]
filter.run();
boolean s8Present = filter.isSolidS8Detected();
double s8Rate = filter.getSolidSulfurRemovalRate(); // kg/hr captured
double interval = filter.getChangeIntervalHours(); // hours until element change
### Particle nucleation (optional, for particle-size / filter rating)
ClassicalNucleationTheory cnt = ClassicalNucleationTheory.sulfurS8();
// pair with PopulationBalanceModel for particle-size distribution across the letdown