EOS Parameter Regression Workflow
Guide for fitting equation-of-state parameters to experimental data using NeqSim.
When to Use This Skill
- Fitting binary interaction parameters (kij) to VLE/LLE data
- Matching saturation pressure (bubble/dew point) to lab measurements
- Tuning C7+ characterization to PVT experiments (CME, CVD, DL)
- Validating EOS predictions against NIST or experimental data
- Selecting the best EOS for a specific fluid system
Regression Strategy
For reservoir material-balance handoff, use CalibratedPvtModel to freeze original
and independently tuned fluids with sample/model/laboratory revision references.
Compare complete held-out CCE/CVD/DLE and separator experiments before accepting
the tuned model. Never split rows from one depletion experiment between tuning and
validation. MaterialBalancePvtHistory requires an explicitly attributed depletion
and separator path; constant-composition flash tables cannot be passed as CVD/DLE
history. It checks alignment and provenance fields, not the external evidence's
truth or experimental accuracy. See docs/pvtsimulation/reservoir_material_balance.md
and hand off measured-history volume estimation to @field-development, keeping
laboratory EOS calibration separate from reservoir/aquifer fitting.
For explicit finite uncertainty scenarios, hand the frozen laboratory model to
ReservoirHistoryEnsemble rather than fitting EOS parameters against field volume.
Its posterior parameterQuantiles(q) reports marginal lower-tail in-place volume
and support assumptions in getParameterNames() order; pressureQuantiles(q)
reports model-pressure uncertainty. Zero/one select the positive-mass support
endpoints, including a tiny positive tail or explicit infinite capacity. Marginal
quantiles are not one joint scenario, continuous posterior coverage, petroleum
exceedance P10 or recoverable reserves. Retain grid/prior/EOS/history sensitivity
and the independent evidence boundary in
docs/pvtsimulation/reservoir_aquifer_uncertainty.md.
Step 1: Select Base EOS
| Fluid System | Recommended EOS | Reason |
|-------------|----------------|--------|
| Light hydrocarbons (C1-C6) | SRK or PR | Well-characterized, reliable kij |
| Oil with C7+ | PR with volume correction | Better liquid density |
| Water + hydrocarbons | SRK-CPA | Handles hydrogen bonding |
| CO2 + hydrocarbons | PR or SRK | Good CO2 fugacity |
| Glycol systems (MEG, TEG) | SRK-CPA | Polar + associating |
| Electrolytes | Electrolyte-CPA | Ion interactions |
Step 2: Gather Experimental Data
For reported gas-phase p/T/Z/molar-mass/density tuples, apply the optional
PvtGasDensityConsistency gate before regression. All quantities must describe
the same phase/state and molar-volume basis; pressure is absolute Pa, temperature
K, molar mass kg/mol, density kg/m3. Freeze justified absolute bounds first and
retain failing rows and source/page/table/row identities. Do not treat printed
precision as measurement sigma or widen bounds to manufacture agreement. Passing
same-sample evidence can be frozen in CalibratedPvtModel via its overload.
See docs/pvtsimulation/laboratory_gas_density_consistency.md and its executable
regression; the check is arithmetic compatibility, not independent accuracy.
For saturated-vapor-reference gas-condensate CVD, screen the complete observed
experiment with CvdMaterialBalance before fitting. Use absolute Pa, constant K,
liquid volume per initial saturated cell volume and cumulative moles per initial
mole. Each withdrawal uses that endpoint vapor composition. Preserve source row
IDs, smoothed/adjusted versus raw analyses, and separately attributed final liquid
analysis bounds. Absent/unresolved/inconsistent liquid has no available composition;
never normalize or clip failed inventories. Optional checkpoint attachment uses
CalibratedPvtModel(..., gasDensityEvidence, cvdEvidence) and rejects a failed or
wrong-sample report. Arithmetic consistency is not independent measured accuracy.
See docs/pvtsimulation/laboratory_cvd_material_balance.md; the primary NS-1
calculated liquid is a numerical reference, while experimental CH4/C7+ remain
incompatible with printed-rounding-only bounds. Wet, critical and other reference
protocols are outside this gate, not silently extrapolated.
Required data types by priority:
- Saturation pressure (bubble/dew point) at reservoir temperature — most critical
- Liquid density at reservoir conditions — validates volume translation
- GOR/Rs from separator tests — validates phase split
- Viscosity — validates transport property correlations
- Compositional data from CVD/DL — validates K-values
Step 3: Set Up Regression in NeqSim
// Create fluid
SystemInterface fluid = new SystemPrEos(273.15 + 100.0, 200.0);
fluid.addComponent("methane", 0.70);
fluid.addComponent("ethane", 0.10);
fluid.addComponent("propane", 0.05);
fluid.addComponent("n-heptane", 0.15);
fluid.setMixingRule("classic");
// Access binary interaction parameters
fluid.setMixingRule("classic");
// Get current kij
double kij = fluid.getPhase(0).getMixingRule()
.getBinaryInteractionParameter(0, 3); // methane-nC7
// Set modified kij
fluid.getPhase(0).getMixingRule()
.setBinaryInteractionParameter(0, 3, 0.02);
fluid.getPhase(1).getMixingRule()
.setBinaryInteractionParameter(0, 3, 0.02);
Step 4: Define Objective Function
// Calculate saturation pressure
ThermodynamicOperations ops = new ThermodynamicOperations(fluid);
ops.bubblePointPressureFlash(false);
double calcPsat = fluid.getPressure("bara");
// Compare with experimental
double expPsat = 250.0; // bara (from lab)
double error = Math.abs(calcPsat - expPsat) / expPsat * 100.0;
Step 5: Iterate and Optimize
# Python regression loop using scipy
from scipy.optimize import minimize_scalar
from neqsim import jneqsim
def objective(kij_value):
fluid = jneqsim.thermo.system.SystemPrEos(373.15, 200.0)
fluid.addComponent("methane", 0.70)
fluid.addComponent("n-heptane", 0.30)
fluid.setMixingRule("classic")
fluid.getPhase(0).getMixingRule().setBinaryInteractionParameter(0, 1, kij_value)
fluid.getPhase(1).getMixingRule().setBinaryInteractionParameter(0, 1, kij_value)
ops = jneqsim.thermodynamicoperations.ThermodynamicOperations(fluid)
ops.bubblePointPressureFlash(False)
calc_psat = fluid.getPressure("bara")
exp_psat = 250.0
return (calc_psat - exp_psat) ** 2
result = minimize_scalar(objective, bounds=(-0.05, 0.10), method='bounded')
print(f"Optimized kij = {result.x:.4f}")
PVT Experiment Matching
Constant Mass Expansion (CME)
// Match relative volume vs pressure
SystemInterface fluid = createCharacterizedFluid();
ThermodynamicOperations ops = new ThermodynamicOperations(fluid);
double[] pressures = {400, 350, 300, 250, 200, 150, 100}; // bara
double[] expRelVol = {0.95, 0.97, 0.99, 1.00, 1.05, 1.15, 1.35};
for (int i = 0; i < pressures.length; i++) {
fluid.setPressure(pressures[i], "bara");
ops.TPflash();
fluid.initProperties();
double calcVol = fluid.getVolume("m3");
// Compare with expRelVol[i]
}
Constant Volume Depletion (CVD)
// Match gas Z-factor and liquid dropout
SystemInterface fluid = createCharacterizedFluid();
neqsim.pvtsimulation.simulation.ConstantVolumeDepletion cvd =
new neqsim.pvtsimulation.simulation.ConstantVolumeDepletion(fluid);
cvd.setPressures(new double[]{350, 300, 250, 200, 150, 100});
cvd.setTemperature(373.15);
cvd.runCalc();
double[] calcZgas = cvd.getZgas();
double[] calcLiqVol = cvd.getRelativeVolume();
C7+ Characterization Tuning
TBP Fraction Setup
SystemInterface fluid = new SystemPrEos(273.15 + 100.0, 200.0);
fluid.addComponent("methane", 0.60);
fluid.addComponent("ethane", 0.08);
fluid.addComponent("propane", 0.05);
fluid.addComponent("n-butane", 0.03);
fluid.addComponent("n-pentane", 0.02);
// TBP fractions: (name, moleFrac, MW_kg/mol, density_g/cm3)
fluid.addTBPfraction("C7", 0.05, 92.0 / 1000, 0.727);
fluid.addTBPfraction("C8", 0.04, 104.0 / 1000, 0.749);
fluid.addTBPfraction("C9", 0.03, 119.0 / 1000, 0.768);
fluid.addPlusFraction("C10", 0.10, 200.0 / 1000, 0.830); // no "+" in the name -- breaks parsing
fluid.getCharacterization().configureLumping().model("standard").totalPseudoComponents(6).build();
fluid.getCharacterization().characterisePlusFraction();
fluid.setMixingRule("classic"); // MUST come AFTER characterisePlusFraction() -- see below
When an assay includes a plus fraction with zero moles, characterization preserves its name, inventory and properties. After adding material to that entry, characterize again before setting the mixing rule.
Ordering note (confirmed 2026-10-12 against a real NeqSim 3.24.0 build):
characterisePlusFraction() can SPLIT a plus/TBP fraction into several
lumped pseudo-components, changing the total component count. Setting the
mixing rule BEFORE that split leaves the EOS's kij matrix sized for the
pre-split count; the first flash that actually needs the matrix then throws
ArrayIndexOutOfBoundsException: Index N out of bounds for length N inside
EosMixingRuleHandler$ClassicSRK.getkij. Always characterize first, then
set the mixing rule.
**Lumping count note (confirmed 2026-10-12, PR review on #4303, reproduced
with a failing JUnit assertion):** do NOT call
fluid.getCharacterization().getLumpingModel().setNumberOfLumpedComponents(n)
directly on the default ("standard") lumping model to control the total
pseudo-component count -- StandardLumpingModel.generateLumpedComposition()
overwrites numberOfLumpedComponents with numberOfPseudocomponents (both
default to 7) at generation time, so setNumberOfLumpedComponents(6) alone
still produces 7 pseudo-components (12 total components here: 5 real + 4
TBP/plus heavy fractions lumped into 7), not 6 (11 total). Use
configureLumping().model("standard").totalPseudoComponents(n).build(),
which sets numberOfPseudocomponents directly -- the field the generator
actually reads.
Tuning Parameters
| Parameter | Effect | Typical Range |
|-----------|--------|---------------|
| Plus fraction MW | Shifts Psat, GOR | ±10-20% of measured |
| Plus fraction density | Adjusts liquid density | ±2-5% of measured |
| Number of lumped components | Accuracy vs speed | 3-12 fractions |
| kij (C1-C7+) | Fine-tunes Psat | -0.02 to +0.05 |
Validation Checklist
- [ ] Saturation pressure within ±2% of experimental
- [ ] Liquid density within ±3% of measured
- [ ] GOR within ±5% of separator test
- [ ] Z-factor within ±2% of CVD data
- [ ] Oil formation volume factor within ±3%
- [ ] Viscosity within ±20% (transport properties have larger uncertainty)
- [ ] Gas condensate: dew point within 10 % and C7+ density within 3 %; CME/CVD not degraded by the tuning
- [ ] Report the result as a
pvt_tuning_qualityblock (before = untuned template, after = tuned, parameters with
bounds and at-bound flags, excluded data with reasons): see neqsim-professional-reporting Principle 9a
- [ ] Lab data checked for physical validity first: a gas "CME" that stays near 1.0 was run on separator liquid
Common Pitfalls
- Overfitting: Don't tune more parameters than you have independent data points
- Non-unique solutions: Multiple kij sets can match Psat — validate with additional data
- Temperature extrapolation: Fitted parameters may not work at different temperatures
- Compositional shift: Parameters fitted to one composition may fail for depleted fluids
- Forgetting
setMixingRule: Must call before accessing kij parameters - Wrong units: MW in kg/mol (not g/mol) for
addTBPfraction - Changing a CPA component's
TCsilently changes its fitteda(T): CPA uses
a(T) = a0 (1 + c1 (1 - sqrt(T/Tc)))^2, so correcting TC in COMP.csv breaks the vapour-pressure fit.
Because sqrt(a) is linear in sqrt(T), re-express exactly: keep K = sqrt(a0)(1+c1) and
S = sqrt(a0) c1 / sqrt(Tc), then sqrt(a0') = K - S sqrt(Tc') and c1' = S sqrt(Tc') / sqrt(a0').
The Peneloux shift (racketZCPA) also scales with Tc/Pc, so refit it to liquid density afterwards.
This was applied and measured for glycerol on 2026-11-14 (#4069): vapour pressure was identical before and after,
and density was within 0.05 % at 0–100 °C. See the
Mechanics of Applying Tuning (read before writing a regression loop)
Iterate `getPhases()`, never `getPhase(i)`
getPhase(i) resolves through the phase-index map. On a single-phase system
getPhase(0), getPhase(1) and getPhase(2) can all return the same phase
object, while other phase objects the flash will later use are never touched.
Always walk the raw array:
for phase in fluid.getPhases():
if phase is None: # the array has 6 slots, several are null
continue
c = phase.getComponent(i)
c.setTC(c.getTC() * tc_mult)
c.setPC(c.getPC() * pc_mult)
Regress in the representation you export
Applying parameters fitted on a 40-component characterization to a 22-component
lumped fluid moved the dew point 12%. Run the regression on the lumped fluid in
its own right and the lumping error disappears by construction. Round-trip the
exported E300 file and re-check Psat and density — that is the only proof the
delivered file is the model you fitted.
Do not regress a parameter the data cannot see
On a gas condensate, every CME density point is single-phase gas where the heavy
pseudo-components are ~1 mol%; their Péneloux volume shift moves mixture density
by <0.02%. A regression drives it to whichever bound it is given while barely
changing the objective — and that arbitrary value then dominates the *condensate
liquid* density in the reservoir model. Check the objective across the bound
range before including a parameter; if it is monotonic to the bound, drop it and
keep the correlation value.
`VOLUME_SHIFT_C7PLUS` scales the effective shift
RegressionParameter.VOLUME_SHIFT_C7PLUS multiplies the effective Peneloux shift of each
plus/TBP fraction (Rackett correlation, dimensionless constant or E300 SSHIFT). Before the
#5195 fix it scaled only the dimensionless constant, which is zero for characterised fractions,
so the parameter had no effect. It changes liquid density only with useVolumeCorrection(true).
Compare simulated DL/CCE volumes with lab data on the same basis: NeqSim now reports
Peneloux-corrected relative volume, Z and Bg, gas gravity relative to air at 28.96546 g/mol and
DL Rs with Z = 1 standard gas (setUseIdealGasStandardVolume(false) for real-gas Z). See
docs/pvtsimulation/pvt_lab_tests.md and PvtVolumeConventionsTest.
Plus-fraction back-out fails on lean gas
Backing MW(C36+) out of the C7+ mass balance works for a black oil but not when
the plus fraction is 0.001–0.006 mol%: the residual is smaller than the reporting
precision and the molecular weight comes out negative. Instead keep the Katz SCN
shape and rescale it with one MW factor and one SG factor to reproduce the
measured mw7p and den7p — both factors are simply lab/Katz.
Saturation-pressure flashes on near-critical fluids
dewPointPressureFlash() and dewPointPressureFlashHC() can return the initial
guess plus a small offset, so the "saturation pressure" silently tracks whatever
start value the regression supplied. Verify against a pressure scan before
trusting them. A reliable fallback is bisection on the pressure where TPflash
first produces a second phase — but clone the fluid for every evaluation,
because a reused fluid object carries its previous converged K-values into the
next flash and the answer then depends on the order the bracket is walked.
Cross-check the result against calcPTphaseEnvelope.
Quantify the data noise floor before chasing residuals
Compare samples that are compositionally near-identical. If two such samples
report saturation pressures 24% apart, no EOS will fit both; tuning harder just
fits noise. Report bias and scatter separately, and stop when the scatter matches
the data's own inconsistency.
Explicit initial-volume depletion handoff
DepletionPvtHistoryGenerator.replayNativeFixedCell preserves original/tuned
checkpoints and fixed separator provenance for independently declared initial
occupied-volume experiments. Its immutable reference is not a dew-point estimate
or measured saturation normalization. The bounded gas-bearing phase family must
remain unchanged; critical and other-phase states fail. Keep the ordinary
replayNative laboratory protocol separate. See
docs/pvtsimulation/depletion_pvt_generation.md and
FixedCellDepletionHandoffTest; synthetic EOS consistency does not establish
measured calibration, held-out experiment accuracy or recoverable reserves.
Explicit-reference fixed-cell replay refines accepted endpoints through the existing
multiphase beta solver to 1e-12 equilibrium and relative volume targets. Preserve all
phase-family, Gibbs and component gates; failed refinement rejects the transaction.
The Gibbs trial must use the same stored component inventory: the caller reconstructs
a feasible homogeneous-phase allocation on copies before comparing energies. Keep
FixedCellFeasibleGibbsTest alongside the independent fixed-cell references; this
fix does not relax energy/fugacity/balance bounds or qualify global stability.
Its108 SRK/PR/volume-correction controls check analytic extensivity and fresh
homogeneous construction only; do not treat them as new depletion-path admission
or independent EOS/measurement accuracy. Preserve the frozen EOS_CONTROL_SCOPE.md.
Precise restoration reuses its caller-qualified endpoint before the first volume
check and reflashes after withdrawal; preserve FixedCellInitialStateTest's named
zero-inventory and independent binary controls. Do not widen volume tolerances
to conceal a repeated-flash inventory perturbation. Legacy CVD keeps its sequence.
Do not weaken absolute inventory bounds or claim arbitrary-scale/measured accuracy.
The original 216-state and intermediate 480-state matrices use identical frozen bounds.
For independently declared dry initial-volume experiments with oil appearance or
loss, use DepletionPvtHistoryGenerator.replayNativeDryPhaseChangingFixedCell
(core ConstantVolumeDepletion.runDryPhaseChangingFixedCellDepletion). Preserve
FixedCellResult.allowsDryPhaseChanges() with the immutable experiment reference.
The existing fixed-cell method retains its unchanged-family contract. Gas must
remain; water/aqueous/other phases, critical-degenerate splits and unclosed paths
fail transactionally. Every local refinement retains its phase-family/Gibbs/
component gates; between-endpoint dry oil appearance/disappearance is permitted.
DryFixedCellPhaseTransitionTest and the fixed-cell-transitions reference qualify
27dry binary SRK paths at three scales/both checkpoint selections, including the
gas-only pressure-grid limit and every separator inventory. This is independent
numerical consistency, not measured calibration, reservoir prediction or Tran RCVD.
Read docs/pvtsimulation/depletion_pvt_generation.md#dry-phase-changing-fixed-cell-experiment.
Explicit wet-gas/aqueous fixed-cell path
Use DepletionPvtHistoryGenerator.replayNativeWetGasFixedCell (core
ConstantVolumeDepletion.runWetGasFixedCellDepletion) only for a separately
accepted initial-occupied-volume gas/aqueous experiment. Aqueous liquid may
disappear; aqueous appearance/reappearance is rejected; gas must remain and
oil/other phases fail transactionally.
Water carried in produced gas is conserved through the unchanged separator.
Preserve checkpoint selection, whole-experiment identity and actual final-product
basis. allowsWetGasPhaseChanges() is distinct from the dry protocol flag.
No wet-dew inference, saturation-normalized CVD, black-oil extrapolation,
reservoir-volume fitting or measured-accuracy claim follows from this route.
Read WetGasFixedCellHandoffTest and the frozen independent reference at
src/test/resources/neqsim/pvtsimulation/wet-gas-fixed-cell/.
Read OFFGRID_SCOPE.md and OFFGRID_VALIDATION.md in that reference folder for
27 additional 20-pressure paths, unchanged bounds and separately labeled
current-master compatibility. Numerical case counts are not independent
experimental measurements or laboratory/reservoir holdout evidence.
Guide: docs/pvtsimulation/depletion_pvt_generation.md#wet-gas-fixed-cell-aqueous-transitions.