Distillation Design Rules
Guide for distillation column modeling and design in NeqSim.
Column Setup Pattern
import neqsim.process.equipment.distillation.DistillationColumn;
import neqsim.process.equipment.stream.Stream;
import neqsim.thermo.system.SystemSrkEos;
import neqsim.thermo.system.SystemInterface;
// Create feed
SystemInterface feed = new SystemSrkEos(273.15 + 50.0, 15.0);
feed.addComponent("methane", 0.10);
feed.addComponent("ethane", 0.25);
feed.addComponent("propane", 0.30);
feed.addComponent("n-butane", 0.20);
feed.addComponent("n-pentane", 0.15);
feed.setMixingRule("classic");
Stream feedStream = new Stream("feed", feed);
feedStream.setFlowRate(10000.0, "kg/hr");
feedStream.setTemperature(50.0, "C");
feedStream.setPressure(15.0, "bara");
feedStream.run();
// Create column (name, simpleTrayCount, hasReboiler, hasCondenser)
DistillationColumn column = new DistillationColumn("Deethanizer", 15, true, true);
column.addFeedStream(feedStream, 8); // Feed on stage 8
// Specifications
column.setCondenserTemperature(273.15 - 30.0); // Kelvin
column.getReboiler().setHeatInput(1e6); // Watts
// Alternatively replace the condenser temperature specification with:
// column.setCondenserRefluxRatio(2.5);
column.run();
Solver Selection
Default set-up for agent work (measured)
Use NEWTON as the first solver, check the result, and fall back explicitly. Do not use AUTO as
the default: on the benchmark below it was neither faster nor more robust than a fixed choice.
column.setSolverType(DistillationColumn.SolverType.NEWTON);
column.run();
if (!column.solved()) {
// MESH_RESIDUAL either returns a residual-verified state or fails; it never hands back
// reconciled products as a converged answer.
column.setSolverType(DistillationColumn.SolverType.MESH_RESIDUAL);
column.run();
}
if (!column.solved()) {
throw new IllegalStateException(column.getConvergenceDiagnostics());
}
DistillationColumn.SolveStatus status = column.getLastSolveStatus(); // report it with the result
DistillationColumn.SolverType used = column.getLastSolverTypeUsed(); // may differ after a fallback
Evidence (2026-11, seven SRK light-hydrocarbon columns of 5-20 trays, each solver on the nominal
case plus 21 perturbed feeds/pressures/duties; see docs/process/equipment/distillation.md,
"Choosing a solver"):
| Solver | Failures in 21 perturbed runs | Time for the 21 runs | Use it for |
|--------|-------------------------------|----------------------|------------|
| NEWTON | 0 | 59 s | Default. Fastest of the solvers with no failures |
| MATRIX_INSIDE_OUT | 0 | 66 s | Equivalent alternative |
| INSIDE_OUT | 0 | 134 s | Same answers as NEWTON, slower |
| MESH_RESIDUAL | 2 (fails instead of reconciling) | 121 s | Verification; fastest on condenser + reboiler columns with a reflux specification |
| NAPHTALI_SANDHOLM | 1 | 2-3x slower on 10+ trays | Residual-driven cross-check |
| DIRECT_SUBSTITUTION, DAMPED_SUBSTITUTION, WEGSTEIN | 2 | 42-48 s | Short reboiled columns (10 trays or fewer): fastest there since Anderson mixing |
| SUM_RATES | 2 | 25 s | Reboiler-only strippers and absorbers |
| AUTO | 2 | 49 s | Not as a default; failed the 15-tray stabiliser after 14 s where NEWTON solved it in 2.4 s |
Rules that follow from the measurements:
NEWTONcan finish asRECONCILED_PRODUCTS. On the 5-tray deethanizer its products then
closed the feed to 0.014 %, not to machine precision. If the status is not RIGOROUS_CONVERGED
and the result feeds a material balance or a guarantee, rerun with MESH_RESIDUAL.
- 15 trays or more: never start with
DIRECT_SUBSTITUTION,DAMPED_SUBSTITUTION,WEGSTEIN
or NAPHTALI_SANDHOLM; they were 2-3x slower than NEWTON and the sequential ones did not
converge the stabiliser.
- Solvers do not agree to more than about 0.1-0.3 % on product rates at default tolerances.
Sequential substitution stops on the sweep step, not on the distance to the solution. Quote the
solver and getLastSolveStatus() with every result, and cross-check a result that feeds a
decision with a second solver family (NEWTON vs MESH_RESIDUAL).
- Narrow-boiling mixtures (for example C4/C5/C6 debutanizer trays) need a build that contains
the bracketed tray PH flash (PR #4981). Before it, several solvers failed after 20-70 s.
- Anderson mixing in the sequential solvers is on by default for cold solves and off for warm
restarts, side-draw/pumparound/specification loops, Murphree efficiency below one and a
user-set iteration cap. column.setAndersonAccelerationEnabled(false) gives plain damped
substitution; getLastAndersonAccelerationCount() reports whether it was used and
getLastAndersonRejectionCount() how many mixing phases were rolled back (nonzero means it
cost sweeps without helping; disable it for that column).
- This evidence does not cover CPA or other associating fluids, absorbers without reboiler, side
draws or pumparounds. Measure before recommending a solver there, and add the result here.
Vacuum MEG regeneration
For salt-free water–MEG, use explicit reboiler duty and partial-condenser molar reflux ratio.
Initialize terminal temperatures through setSeedTemperature, then require
RIGOROUS_CONVERGED, closed energy across each adiabatic tray, and stationary internal
flows. In the November 17 tests, direct substitution with the bracketed tray PH flash
closed the one-tray binary case, a nearby duty change, and a three-tray case with trace
methane. This evidence applies to those SRK–CPA cases near 0.8 bara. For duty sweeps, verify
the published reboiler duty after each change and compare a nearby retained-state solve
with a fresh solve.
When reporting MEG loss, compare vapor MEG composition with data near the relevant
pressure and temperature. Keep the column conservation result and the vapor-composition
error visible in the engineering report. The
MEG benchmark in the equipment guide
lists the measured points and the SRK–CPA error before fitting.
All solver types
// Direct substitution (default) - sequential tray sweeps with Anderson mixing on cold solves
column.setSolverType(DistillationColumn.SolverType.DIRECT_SUBSTITUTION);
// Inside-Out — flow correction with K-value tracking
column.setSolverType(DistillationColumn.SolverType.INSIDE_OUT);
// Adaptive matrix inside-out — bypasses matrix setup on small columns,
// tries a component-balance matrix warm start on larger columns, then
// finishes with rigorous inside-out polishing
column.setSolverType(DistillationColumn.SolverType.MATRIX_INSIDE_OUT);
// Damped substitution - for difficult convergence
column.setSolverType(DistillationColumn.SolverType.DAMPED_SUBSTITUTION);
// MESH residual monitor - for residual auditing
column.setSolverType(DistillationColumn.SolverType.MESH_RESIDUAL);
// Naphtali-Sandholm - guarded simultaneous MESH residual Newton solver
column.setSolverType(DistillationColumn.SolverType.NAPHTALI_SANDHOLM);
// Optional: seed stage temperatures as initial guesses only, not fixed specs
column.setSeedTemperature(3, 273.15 + 45.0);
// Adjust max iterations
column.setMaxNumberOfIterations(200);
Runtime control: iteration budget, damping and tolerance
Three knobs decide how long a column runs before it gives up. Getting them wrong
is the usual cause of a column that burns minutes per solve inside a
ProcessModel outer loop.
// 1. ITERATION BUDGET — setMaxNumberOfIterations(n) is only a SOFT FLOOR.
// The effective budget is max(n, 5 * numberOfTrays) and can still be expanded
// by the overflow/polish extensions. setMaxNumberOfIterations(10) on an
// 11-tray column therefore does NOT cap anything (11*5 = 55 -> ~187 with
// overflow). NeqSim logs a warning when the request is below the tray floor.
column.setMaxNumberOfIterations(20, true); // HARD cap (2-arg overload)
column.setHardIterationCap(true); // or flip the flag separately
column.getEffectiveMaxNumberOfIterations(); // what the solver will actually use
// 2. DAMPING — the adaptive controller clamps the sequential step at
// minSequentialRelaxation (default 0.5). setRelaxationFactor now lowers that
// floor when you ask for heavier damping, so a request below 0.5 takes effect
// instead of being silently clamped back. Use this to break limit cycles.
column.setRelaxationFactor(0.3);
column.setMinSequentialRelaxation(0.2); // explicit floor if needed
column.setMinInsideOutRelaxation(0.2); // inside-out tear streams
// 3. TOLERANCE — the default absolute temperature tolerance (~0.02-0.03 K) can
// be ~10x tighter than the enclosing ProcessModel boundary gate (1e-3
// relative ~ 0.27 K at 270 K), so the column keeps iterating on a residual
// the plant model already accepts. Align them:
column.setTemperatureToleranceRelative(1.0e-3); // returns the absolute K value
column.getReferenceTemperature(); // basis used for the conversion
Rule of thumb for a column inside a multi-area ProcessModel: set a hard
iteration cap, damp below 0.5 if the tray temperatures oscillate, and match the
column tolerance to the model tolerance passed to
ProcessModel.runUntilConverged(maxIter, tol).
What `solved()` actually checks
solved() is not a single residual. It requires the solve status to be
RIGOROUS_CONVERGED or RECONCILED_PRODUCTS and every active residual gate
to pass:
| Gate | Source | Default tolerance |
|------|--------|-------------------|
| Temperature | mean per-tray change of the last sweep | ~0.02 K x complexity; NaN for simultaneous solvers, which then require the MESH gate instead |
| Mass | external feed/product balance | ~0.016 x complexity |
| Energy | tray enthalpy balance | not enforced by default (setEnforceEnergyBalanceTolerance(true)) |
| Internal traffic | max tray traffic / feed | 100 |
| Per-tray material balance | getLastTrayMaterialBalanceError() — summed absolute tray imbalance / tray throughput | getTrayMaterialBalanceTolerance(), default 0.02 |
| MESH infinity norm | all residual families | getMeshResidualTolerance(), default 1.0 |
The overall feed/product balance closing to machine precision does not mean
the column solved: each tray must close its own component balance too. Read
per-tray material imbalance in getConvergenceDiagnostics() before trusting
duties or a tray profile.
Do not gate on the MESH
material:infinity norm. Those entries scale each
component by its own throughput, so a trace component going from 1e-25 to
1.2e-25 mol/hr reads as a 0.17 residual. Use
getLastTrayMaterialBalanceError(), which weights by tray throughput.
Solver Selection Guide
| System Type | Recommended Solver | Notes |
|------------|-------------------|-------|
| Any hydrocarbon column, first attempt | NEWTON | Measured default, see "Default set-up for agent work" |
| Short reboiled HC column (10 trays or fewer), cold solve | DIRECT_SUBSTITUTION | Fastest there with Anderson mixing; status may be RECONCILED_PRODUCTS |
| Condenser + reboiler with reflux specification | MESH_RESIDUAL | Fastest and residual-verified on the depropanizer/debutanizer cases |
| Larger HC fractionators | MATRIX_INSIDE_OUT or NEWTON | Adaptive: small columns bypass matrix overhead; larger columns try the matrix warm start before rigorous inside-out polishing |
| Non-ideal (alcohols, water) | DAMPED_SUBSTITUTION or DIRECT_SUBSTITUTION | More conservative for non-ideal K-values |
| Absorbers (no condenser/reboiler) | SUM_RATES or DIRECT_SUBSTITUTION | Flow-corrected updates can help absorber/stripper cases |
| Wide-boiling (C1 to C20+) | DAMPED_SUBSTITUTION | Increase iterations and monitor residuals |
| Cryogenic (< -100°C) | INSIDE_OUT with residual diagnostics | Careful with phase identification |
| Solver audit / residual convergence | MESH_RESIDUAL or NAPHTALI_SANDHOLM | MESH_RESIDUAL records diagnostics and enforces the MESH/product-draw gate by default; NAPHTALI_SANDHOLM attempts guarded simultaneous MESH correction |
Column Specification Combinations
| Bottom Spec | Top Spec | Comment |
|------------|---------|---------|
| Reboiler duty | Condenser temperature | Most common |
| Reboiler duty | Reflux ratio | Alternative |
| Top product purity | Reboiler duty | Product-quality control |
| Bottom temperature | Reflux ratio | Direct T control |
// Common specification patterns
// Pattern 1: Condenser T + Reboiler duty
column.setCondenserTemperature(273.15 - 30.0);
column.getReboiler().setHeatInput(1.5e6);
// Pattern 2: Reflux ratio + Reboiler duty
column.getCondenser().setRefluxRatio(3.0);
column.getReboiler().setHeatInput(2.0e6);
// Pattern 3: Product quality plus boilup ratio
column.setTopProductPurity("ethane", 0.98);
column.setReboilerBoilupRatio(2.0);
Reading Column Results
For a terminal energy balance, sum the published streams' extensive enthalpy rates.
A closed total-condenser reflux outlet carries zero enthalpy and entropy rates. Read
molar or mass-specific properties only on flowing products.
column.run();
// Condenser and reboiler duties
double condenserDuty = column.getCondenser().getDuty(); // Watts
double reboilerDuty = column.getReboiler().getDuty(); // Watts
// Product streams
Stream overhead = (Stream) column.getGasOutStream();
Stream bottoms = (Stream) column.getLiquidOutStream();
// Stage temperatures and compositions
for (int stage = 0; stage < column.getTrays().size(); stage++) {
double stageTemp = column.getTray(stage).getTemperature() - 273.15;
// Composition on each stage
}
// Convergence metrics
int iterations = column.getLastIterationCount();
double massResidual = column.getLastMassResidual();
double energyResidual = column.getLastEnergyResidual();
boolean matrixWarmStartUsed = column.wasMatrixInsideOutWarmStartUsed();
boolean matrixWarmStartBypassed = column.wasMatrixInsideOutWarmStartBypassed();
int matrixIterations = column.getLastMatrixInsideOutIterationCount();
Feed Tray Location Rules
Kirkbride Correlation
For binary or pseudo-binary separations:
$$
\log\left(\frac{N_R}{N_S}\right) = 0.206 \log\left[\left(\frac{B}{D}\right) \left(\frac{x_{HK,F}}{x_{LK,F}}\right)^2 \left(\frac{x_{LK,B}}{x_{HK,D}}\right)^2 \right]
$$
Where $N_R$ = rectifying stages, $N_S$ = stripping stages, $B/D$ = bottoms/distillate ratio.
Rules of Thumb
| Column Type | Feed Tray (from top) | Notes |
|------------|---------------------|-------|
| Demethanizer | 40-60% of stages | Light key is very volatile |
| Deethanizer | 50-70% of stages | Moderate volatility |
| Depropanizer | 40-60% of stages | Balanced separation |
| Debutanizer | 50-60% of stages | Similar to depropanizer |
| Crude column | 60-80% of stages | Flash zone near bottom |
Minimum Stages and Reflux
Fenske Equation (Minimum Stages)
$$
N_{min} = \frac{\log\left(\frac{x_{LK,D}}{x_{HK,D}} \cdot \frac{x_{HK,B}}{x_{LK,B}}\right)}{\log(\alpha_{LK/HK})}
$$
Underwood Equation (Minimum Reflux)
$$
R_{min} = \frac{1}{\alpha - 1}\left(\frac{x_D}{\alpha - \theta} - \frac{1 - x_D}{1 - \theta}\right)
$$
Design Heuristics
- Actual stages ≈ 2 × minimum stages (Gilliland correlation)
- Actual reflux ≈ 1.2-1.5 × minimum reflux
- Stage efficiency: 50-70% for trays, 70-90% HETP/stage for packing
Convergence Troubleshooting
| Problem | Solution |
|---------|----------|
| Column does not converge | Switch solver first (NEWTON, then MESH_RESIDUAL); only then increase max iterations to 200-500 |
| Oscillating temperature profile | Reduce condenser/reboiler specs, use DAMPED_SUBSTITUTION; audit with MESH_RESIDUAL before trying NAPHTALI_SANDHOLM |
| Wrong product split | Check feed tray location and specifications |
| Negative flows on stages | Too many stages or wrong specifications |
| Condenser too cold | Check if subcooled liquid is physical (binary dewpoint) |
| Reboiler too hot | May be decomposing — check component stability |
Steps to Debug
- Start with fewer stages (5-8) and get convergence
- Gradually increase stages
- Use liberal specifications first (higher reflux), then tighten
- Check feed condition (vapor fraction) — subcooled feed may need enthalpy adjustment
- Verify component K-values make physical sense at column conditions
Column Sizing (Diameter)
Souders-Brown Correlation
$$
V_{flood} = K_{SB} \sqrt{\frac{\rho_L - \rho_V}{\rho_V}}
$$
Where $K_{SB}$ = 0.03-0.07 m/s for trays, 0.02-0.05 for packing.
Design velocity = 70-85% of flooding.
// After running column, get phase properties for sizing
SystemInterface topFluid = column.getTray(0).getFluid();
topFluid.initProperties();
double rhoV = topFluid.getPhase("gas").getDensity("kg/m3");
double rhoL = topFluid.getPhase("oil").getDensity("kg/m3");
double Ksb = 0.05; // m/s for sieve trays
double Vflood = Ksb * Math.sqrt((rhoL - rhoV) / rhoV);
double Vdesign = 0.80 * Vflood;
double gasFlow = column.getGasOutStream().getFlowRate("m3/hr") / 3600.0;
double area = gasFlow / Vdesign;
double diameter = Math.sqrt(4.0 * area / Math.PI);
Internals Selection
| Internals | When to Use | Typical HETP (m) |
|-----------|------------|-------------------|
| Sieve trays | General service, fouling | 0.5-0.7 |
| Valve trays | Variable turndown | 0.4-0.6 |
| Bubble cap trays | Low liquid rates | 0.5-0.8 |
| Random packing (Pall rings) | Low pressure drop, corrosive | 0.3-0.6 |
| Structured packing (Mellapak) | Vacuum, low ΔP | 0.2-0.5 |
Common Pitfalls
- Feed flash: Ensure feed is at correct T/P for column conditions
- Missing components: All components in feed must be present in EOS
- Mixing rule: Always set before column construction
- Heavy key in top / light key in bottom: Small amounts are normal — zero means perfect separation (unrealistic)
- Column pressure profile: Default is constant — set stage pressures for realistic profile
- Condenser type: Total vs partial condenser changes mass balance