Neqsim agentic process optimization

From equinor/neqsim · View interactive version

Neqsim agentic process optimization is an AI agent skill from the GitHub repository equinor/neqsim. Agentic closed-loop optimization of large multi-area NeqSim ProcessModel plants with convergence gating and equipment introspection. USE WHEN: an agent must optimize a live full-plant flowsheet (setpoints, compressor pressures, heater temperatures, routing fractions) across years/scenarios with surg

How to use this skill

Skill file

Agentic Process-Model Optimization

This skill is the recipe for an **agent that optimizes a large, already-built

multi-area plant** (e.g. an offshore separation + recompression + export train)

by turning the newest NeqSim automation and introspection APIs into a robust

optimization loop. It assumes the flowsheet is a ProcessModel assembled from

several named ProcessSystem areas (see neqsim-platform-modeling).

Use neqsim-optimization-and-doe for the algorithm (SQP, PSO, BatchStudy,

ProcessSimulationEvaluator → SciPy/Pyomo). Use this skill for the plumbing:

how to read the decision space, evaluate one trial robustly, gate feasibility,

and score the objective from real equipment results.


1. The four pillars (all verified in NeqSim ≥ 3.13.0)

| Need | API | Returns |

|------|-----|---------|

| Decision space (bounded knobs) | ProcessAutomation.getAdjustableParameters() / getAdjustableParametersJson() | List<AdjustableParameter> with name/address/unit/lowerBound/upperBound/source |

| Robust convergence of a coupled plant | ProcessModel.runUntilConverged(int maxIterations, double tolerance) | boolean converged; pair with getConvergenceReportJson() |

| Per-trial feasibility / failure gating | ProcessModel.getRunStatus() / getRunStatusJson(), ProcessSystem.getRunStatus() | RunStatus (completed/success/failedUnitName/failedUnitError) |

| Objective + constraints from equipment | Compressor.getOperatingPoint(), Standard_ASTM_D6377.RvpResult | power, surge/stonewall margins; certified RVP |

Why these matter for an agent: they replace the fragile "call .run() twice

and hope" pattern with explicit did-it-converge and did-any-unit-fail

signals, and they expose objective/constraint numbers (compression power, surge

distance, RVP spec) as structured JSON the agent can parse without walking Java

object trees.


2. Discover the decision space

from neqsim import jneqsim   # or devtools `ns` (see §8)
import json

auto = plant.getAutomation()                      # plant = ProcessModel
# NOTE: jpype returns java.lang.String, not Python str — json.loads needs str(...).
params = json.loads(str(auto.getAdjustableParametersJson()))
for p in params["parameters"]:
    print(p["name"], p["address"], p["unit"], p["lowerBound"], p["upperBound"], p["source"])

pressure, heater outlet temperature, valve outlet pressure, …).

solve it, do not also optimize it (double control = divergence).

the agent MUST supply a physically meaningful [lo, hi] before optimizing.

getAdjustableParameters() surfaces model-side inputs with bounds. If your

decision variables live in a Python driver (e.g. a ProcessInput dataclass or

a year selector), map each one explicitly to a NeqSim address or a rebuild

argument — the registry will not invent them for you.

Prerequisite — the model must already carry the optimization data basis.

getAdjustableParameters() only surfaces knobs the model has, and capacity

constraints only fire if the equipment has design limits. Before optimizing,

confirm the model was built with: line sizes (ID, length, roughness, elevation)

and manifold/header sizes for hydraulics; valve/choke Cv (and choke

Cv-vs-opening); compressor/pump performance maps + speeds; separator

dimensions + design K; equipment design limits (rated power, surge

margin, NPSH, erosional velocity, design P/T, MAWP, valve max Cv); manipulable

setpoints with physical bounds; and the objective + economic/spec basis.

Use enterprise-process-model-build-verify with

target_fidelity="optimization_ready" (its OPTIMIZATION_DATA_BASIS /

optimization_data_basis output) to gather and gate this basis, and

neqsim-process-modeling for the community build checklist.


3. Robust single-trial evaluation (the core helper)

Always gate on convergence and run status. A trial that diverges or throws in

one unit must return a large penalty, never a misleading objective.

def converge(plant, max_iter=30, tol=5e-3, settle_passes=2, soft_maxerr=0.05):
    """Run the coupled ProcessModel until boundary streams stop moving.

    Recycle-heavy plants have near-zero-flow anti-surge recycles that inflate
    the *relative* boundary-error metric (a tiny stream gives a large % error
    even when physically settled), so a strict `tol=1e-4` rarely passes. Accept
    a trial when NO unit threw AND the model either strictly converged or
    reached a relaxed boundary band; keep genuine unit failures infeasible.
    """
    converged = bool(plant.runUntilConverged(int(max_iter), float(tol)))
    for _ in range(settle_passes):                # settle slow recompression loops
        try:
            plant.run()
        except Exception:
            break
    report = json.loads(str(plant.getConvergenceReportJson()))   # str() — jpype String
    status = json.loads(str(plant.getRunStatusJson()))           # str() — jpype String
    failed = status.get("failedUnitName") not in (None, "", "null")
    max_err = report.get("maxError", float("inf"))
    soft_ok = (max_err == max_err) and (max_err < soft_maxerr)   # not NaN and small
    ok = (not failed) and (converged or soft_ok)
    return ok, report, status

def evaluate(plant, setpoints, *, max_iter=30, tol=5e-3):
    """Apply setpoints, converge, score. Returns (objective, record)."""
    try:
        apply_setpoints(plant, setpoints)          # see §4
        ok, report, status = converge(plant, max_iter, tol)
        if not ok:
            failed = status.get("failedUnitName") or report.get("maxError")
            return 1e9, {"feasible": False, "reason": f"non-converged/{failed}", **setpoints}
        obj, parts = objective_and_constraints(plant)   # see §5
        return obj, {"feasible": True, **parts, **setpoints}
    except Exception as exc:                        # JVM exception from a unit
        return 1e9, {"feasible": False, "reason": f"exception:{exc}", **setpoints}

Key rules:

inflate it to ~0.8 even when settled — don't demand tol=1e-4. Gate on

unit failure (failedUnitName) plus a relaxed maxError band, and add a

couple of settling run() passes.

the extra passes only damp slow recompression loops. Raise max_iter, not hacks.

never converges must not hang the optimizer: call plant.setMaxRunTimeSeconds(120.0)

(spans all areas and all passes of runUntilConverged) and

plant.setStallDetection(8, 1e-3) (no residual improvement for 8 iterations) once, and

call plant.requestStop() from a watchdog thread to cancel from outside. A tripped run

returns normally; read status["terminationReason"] (TIMED_OUT / STALLED / STOPPED),

getRunStatus().getBudgetUnitName() (unit that was running) and

plant.getLastRunDiagnostics().toJson(), and score the trial as infeasible. Cooperative

only: one unit that never returns cannot be interrupted. Default is off.

See docs/process/processmodel/run_status.md.

results.json later. Report the best feasible trial (min objective among

feasible=True), never the last evaluate() result — the final call can land

on a non-converged retry and write null power/RVP/surge into results.json.

satisfy two coupled constraints (RVP and compressor surge), say so and add

the relieving lever (recompression suction pressure) to DECISION_VARS; switch

the optimizer from minimize_scalar to scipy.minimize(Nelder-Mead, bounds=…).


4. Apply setpoints (string-addressable, dirty-tracked)

Prefer ProcessAutomation string addresses over walking the object graph:

def apply_setpoints(plant, sp):
    auto = plant.getAutomation()
    updates = {}                                   # address -> value (one unit family)
    if "export_P_bara" in sp:
        updates["Compression::export compressor.outletPressure"] = sp["export_P_bara"]
    auto.setValues(updates, "bara", False)         # batch, no run yet
    # temperatures use a different unit -> separate batch
    if "oil_heater_T_C" in sp:
        auto.setVariableValue("Sep train A::oil heater second stage.outletTemperature",
                              sp["oil_heater_T_C"], "C")
        auto.setVariableValue("Sep train B::oil heater second stage.outletTemperature",
                              sp["oil_heater_T_C"], "C")
    # convergence happens in converge() via runUntilConverged

If addresses are uncertain, self-heal: auto.setVariableValueSafe(addr, val, unit)

returns JSON with an auto-corrected address instead of throwing. Use

auto.validateAddress(addr) (returns None when valid) as a pre-flight check.

When the plant is built imperatively (handles in Python scope), it is equally

valid to set levers directly on the unit and let converge() settle them:

train_A.getUnit("oil heater second stage").setOutTemperature(T, "C").


5. Objective and constraints from real equipment

Compression power + surge/stonewall margin

def compressor_metrics(plant):
    total_power_MW = 0.0
    min_surge_margin = float("inf")
    within_chart_all = True
    for area in plant.getAllProcesses():           # each ProcessSystem
        for u in area.getUnitOperations():
            if u.getClass().getSimpleName() != "Compressor":
                continue
            op = json.loads(str(u.getOperatingPointJson()))   # str() — jpype String
            p = op.get("power_MW")
            if p == p:                              # not NaN
                total_power_MW += p
            d = op.get("distanceToSurge")           # fraction; NaN if no chart
            if d == d:
                min_surge_margin = min(min_surge_margin, d)
            if op.get("withinChart") is False:
                within_chart_all = False
    return total_power_MW, min_surge_margin, within_chart_all

getOperatingPoint() / getOperatingPointJson() fields:

power_MW, polytropicEfficiency, head_kJkg, flow_m3hr, speed_rpm,

distanceToSurge, distanceToStoneWall, surgeFlowRateMargin_m3hr,

withinChart, limitingConstraint (none/surge/stonewall/no_chart).

Uncomputable margins are NaN — always test x == x before using them.

Compressor control mode: solve-speed vs predictive (choose per objective)

A charted compressor can run two ways, and **the mode decides what is an input vs

an output** in your optimization — pick it deliberately:

| Mode | Setup | Fixed (input) | Computed (output) | Use for |

|------|-------|---------------|-------------------|---------|

| Solve-speed (default for most plants) | setOutletPressure(P) + setUseCompressorChart(True) + setSolveSpeed(True) | discharge pressure | speed, power, surge margin | spec/capacity/max-throughput studies where the network has fixed pressure boundaries |

| Predictive | setUseCompressorChart(True) + setSpeed(rpm) + setSolveSpeed(False) (do not pin outlet P) | shaft speed | discharge pressure, head, power, surge margin | speed-as-decision-variable optimization, surge/turndown and dynamic studies |

Rules of thumb:

a process level held by a downstream scrubber/level controller, an import

header), solve-speed is the physically correct steady-state control mode —

the machine trims speed to hold that pressure, and *speed / power / surge

margin are the outputs* you optimize against. This is the right mode for

"max production while meeting RVP / dew-point / cricondenbar", because product

specs are set by separation temperatures/pressures, not by throughput, so the

binding limit is compressor power/surge or separator gas load — all of which

fall out of a solve-speed run.

lowest power while still delivering P_export?"), use predictive mode: fix the

speed, let the chart compute discharge pressure and power. Sweeping speed then

traces the head/power curve directly (e.g. 90 %→95 %→100 %→105 % speed maps to a

monotonically rising discharge pressure and head).

pressure nodes float (e.g. a recompressor whose discharge mixes back into an

upstream stage): fix all speeds, drop the interior setOutletPressure calls,

and let a pressure-node/recycle pass settle the mixer pressures. Do this behind

a PREDICTIVE_PRESSURE toggle so the default solve-speed model (used for spec

and capacity studies) stays intact. Mixing the two modes on the same recycle

loop without a pressure-node pass will diverge.

setSurgeControlFactor(...)) so a turned-down point recycles onto the control

line instead of falling outside the map and returning NaN margins.

Export-oil RVP (certified spec) — use RvpResult

D6377 = jneqsim.standards.oilquality.Standard_ASTM_D6377
def export_oil_rvp_bara(stream, ref_T_C=37.8):
    std = D6377(stream.getFluid())
    std.setReferenceTemperature(ref_T_C, "C")      # if available on the build
    res = std.getRvpResult(D6377.RvpMethod.RVP_ASTM_D6377)
    r = json.loads(str(res.toJson()))              # str() — jpype String; {value, unit, method, referenceTemperatureC, valid}
    return r["value"], r["valid"]

The convenience stream.getRVP(37.8, "C", "bara", "RVP_ASTM_D6377") still works

and is fine inside a hot loop; switch to RvpResult when you need the method

label, reference temperature, and valid flag for the report.

Assemble objective with penalties

def objective_and_constraints(plant, rvp_target=0.79, surge_floor=0.10):
    power_MW, surge_margin, within = compressor_metrics(plant)
    rvp, rvp_valid = export_oil_rvp_bara(export_oil_stream())
    penalty = 0.0
    if not rvp_valid or rvp > rvp_target:
        penalty += 50.0 * max(0.0, rvp - rvp_target) + (0.0 if rvp_valid else 25.0)
    if surge_margin < surge_floor or not within:
        penalty += 100.0 * max(0.0, surge_floor - surge_margin) + (0.0 if within else 50.0)
    objective = power_MW + penalty                 # minimise compression power, feasibly
    return objective, {"power_MW": power_MW, "surge_margin": surge_margin,
                       "rvp_bara": rvp, "penalty": penalty}

Pick the objective from the task: minimise compression power, maximise gas/oil

export, minimise fuel gas, or a weighted blend. Express every constraint as a

soft penalty so gradient-free optimizers degrade gracefully.


6. Choosing the optimizer (defer to neqsim-optimization-and-doe)

Each full-plant evaluation is expensive (seconds–minutes) and the response is

noisy (recycle drift) and non-smooth (regime switches, flares). Therefore:

| Decision space | Recommended | Notes |

|----------------|-------------|-------|

| 1–2 knobs | 1-D/2-D sweep + interpolation | cheapest, most transparent (see notebook RVP-vs-heater sweep) |

| 3–6 continuous knobs | scipy.optimize.minimize(method="Powell") or Nelder-Mead, or NeqSim SQPoptimizer | bound via penalties; small maxiter |

| Global / many local minima | NeqSim Particle Swarm, or coordinate descent restarts | use when sweeps show multimodality |

| Pareto (power vs export) | MultiObjectiveOptimizer | trade-off front |

| Screening / DoE | BatchStudy + ProcessSystem.copy() | parallel, see §7 |

Bridge to SciPy/Pyomo/BoTorch via ProcessSimulationEvaluator when you need

algorithms NeqSim lacks (Bayesian, MINLP). **Do not claim NeqSim has Bayesian

optimization or LHS — it does not.**

Built-in shortcut — AgenticProcessOptimizer (NeqSim ≥ 3.13.0). Before hand-rolling

the §3 evaluate-helper + §6 SciPy loop, consider auto.newOptimizer(): a ready-made

bounded Nelder–Mead search that already does the per-trial evaluate() gating, penalty

folding, trajectory logging, and never-throw JSON contract described in this skill.

Build the problem straight from string addresses:

```python

opt = auto.newOptimizer()

opt.addVariable("Compression::Export Compressor.outletPressure", 80.0, 200.0, "bara")

opt.minimize("Compression::Export Compressor.power", "kW")

opt.addConstraintLessOrEqual("Export Oil.RVP", 0.79, "bara", 1.0e4)

opt.setSeed(42).setMaxEvaluations(80)

result = json.loads(str(opt.optimizeToJson())) # never throws; includes trajectory

readiness = json.loads(str(opt.getReadinessJson())) # ML/agentic self-rating

```

Use the manual SciPy/Pyomo bridge only when you need an algorithm it lacks

(Bayesian, MINLP, true multi-objective Pareto) or parallel deep-copy sweeps (§7).


7. Multi-year / multi-scenario sweeps with deep copies

ProcessSystem.copy() (and ProcessModel rebuild) produce independent deep

copies — verified independent so parallel trials cannot cross-contaminate.

years = [2033, 2034, 2035, 2036]
best = {}
for year in years:
    plant = build_plant(year)          # rebuild the full ProcessModel for the year
    x0 = initial_setpoints(plant)
    res = minimize(lambda x: evaluate(plant, vec_to_sp(x))[0], x0,
                   method="Powell", options={"maxiter": 30, "xtol": 0.5})
    best[year] = collect(plant, res)

balance) changes with Year. Optimizing operating levers on a stale build

gives the wrong answer.

and evaluate trials in separate threads/processes (BatchStudy,

MonteCarloSimulator, or the neqsim_runner subprocess bridge).

classify knobs as "technical" (need a rebuild/converge) vs "operating" (only

re-converge) to cut runtime.


8. Picking up brand-new NeqSim functionality (updates workflow)

New Java methods (like getOperatingPoint, runUntilConverged,

getAdjustableParameters, RvpResult) are only callable once the classes are on

the Python classpath. Two supported paths:

A. Devtools (workspace classes, no repackaging) — best for repo task

notebooks; picks up target/classes ahead of the shaded JAR:

import os, sys
from pathlib import Path
PROJECT_ROOT = Path(r"C:\Users\ESOL\Documents\GitHub\neqsim")
os.environ["NEQSIM_PROJECT_ROOT"] = str(PROJECT_ROOT)
sys.path.insert(0, str(PROJECT_ROOT / "devtools"))
from neqsim_dev_setup import neqsim_init, neqsim_classes
ns = neqsim_init(project_root=PROJECT_ROOT, recompile=False, verbose=True)
ns = neqsim_classes(ns)

Rebuild first if you changed Java: mvnw.cmd compile (or package -DskipTests).

This MUST be the first NeqSim-touching cell — JPype allows one JVM per

process, so any earlier from neqsim import jneqsim locks out the override

(restart the kernel if so).

B. Repackage the JAR into the pip neqsim — best when an existing notebook

already uses from neqsim import jneqsim everywhere and you don't want to touch

100+ cells:

.\mvnw.cmd package -DskipTests
Copy-Item target\neqsim-<version>.jar `
  "$env:APPDATA\Python\Python312\site-packages\neqsim\lib\java11\neqsim-<version>.jar" -Force

Verify in a fresh process before relying on it:

from neqsim import jneqsim
c = jneqsim.process.equipment.compressor.Compressor("c")
assert hasattr(c, "getOperatingPointJson")
assert "runUntilConverged" in dir(jneqsim.process.processmodel.ProcessModel)

8.5 Unified equipment-utilization roll-up + inlet-pressure lower-limit search

To "maximize production within utilization limits" you need a single view that puts

compressors, gas-turbine drivers, and separators/scrubbers on the same 0-1 scale, plus

a way to push an operating variable (e.g. inlet pressure) until the first constraint

binds. Two complementary approaches:

A. NeqSim-native (preferred). Activate every unit's CapacityConstraint, then read

one side-effect-free snapshot:

comp.getMechanicalDesign().setMaxDesignPower(driverSiteRatedKW) so the power

constraint has a basis.

SeparatorMechanicalDesign.setGasLoadFactor(K) -> setRetentionTime(t) ->

readDesignSpecifications() -> calcDesign().

maxUtilization, limitingConstraint, feasible, power_kW, and a plant

bottleneck + anyOverloaded. Drive the search with ProcessAutomation.evaluate()

or AgenticProcessOptimizer.

Native max-throughput-at-capacity (one call, both ProcessSystem and ProcessModel).

`ProcessAutomation.findMaxThroughputJson(feedAddresses, minRate, maxRate, rateUnit,

utilizationLimit)` enables the separator capacity constraints, then bisects the total

feed rate (all feeds scaled proportionally to their base rate) until the first unit's

maxUtilization reaches utilizationLimit (a 0-1 fraction). It leaves the model at the

feasible maximum and returns `{maxRate, rateUnit, feasibleAtMin, bindingUnit,

bindingConstraint, bindingUtilizationPercent}`. This is the string-addressable,

never-throwing replacement for a hand-rolled inlet/feed bisection loop. Pair with

enableCapacityConstraints() / prepareForCapacityStudyJson() /

validateForOptimizationJson() / getBottleneckRankingJson(topN) for the setup and

diagnostics.

Product-quality observables (spec constraints). getProductQualityJson(address)

(optionally with a reference temperature) returns, for a resolved stream (area-qualified

Area::Unit, unit.port, or a bare unit -> its first outlet), the export-oil RVP/TVP

(rvp_bara, tvp_bara via Standard_ASTM_D6377) and the gas cricondenbar_bara /

cricondentherm_K (via calcPTphaseEnvelope), each computed on a cloned fluid so the

live flowsheet is untouched. It never throws — a metric that cannot be computed is

reported as rvpError / envelopeError. Use these as the spec side of a

maximise-throughput-subject-to-RVP/cricondenbar optimisation.

Capacity for ALL equipment types (not just separators).

ProcessAutomation.enableCapacityConstraints() now enables the capacity constraints on

every CapacityConstrainedEquipment in the flowsheet (pumps, valves, pipelines,

heaters/coolers, heat exchangers, manifolds, ...), not only separators — so any of them

can become the binding bottleneck in getUtilizationSnapshot() /

getBottleneckRankingJson() / findMaxThroughputJson(). It deliberately preserves the

chartless-compressor gating (surge/speed stay disabled so utilisation stays smooth and

power-driven) by calling reinitializeCapacityConstraints() on compressors instead of a

blind enableAllConstraints(), and still adds the separator Souders-Brown gas-load

constraint. Set the design basis for each type first (compressor setMaxDesignPower,

pump/valve/pipe design limits, separator setGasLoadFactor) so the utilisation has a

meaningful denominator.

Routing / feed-scale as decision variables (#7). Feed streams already expose

flowRate as a writable INPUT (feed-scale). Splitters now also expose one bounded

splitFactor_i (0-1) INPUT per outlet in getAdjustableParameters() — the routing

decision variables. Reading <Splitter>.splitFactor_i returns the current fraction;

writing it sets that branch's relative weight and the splitter renormalises the factors

to sum to 1. Because they carry [0,1] bounds, AgenticProcessOptimizer.useAdjustableParameters()

picks them up automatically, so the optimizer can redistribute flow between trains/branches

as part of a maximise-production search. (Give feed flowRate explicit bounds if you want

the optimizer to treat feed-scale as a decision variable too.)

Parallel batch evaluation for ML / DoE (#6).

ProcessAutomation.evaluateBatchJson(candidates, unit, readbacks, maxParallel) (and the

full overload with readbackUnit, maxIterations, tolerance) scores a list of setpoint

maps in one call. For a ProcessSystem with maxParallel > 1 it evaluates each candidate

on an independent ProcessSystem.copy() on its own thread, so the batch is genuinely

parallel and the live model is left untouched — ideal for SciPy/BoTorch/GA/agent

populations. For a ProcessModel (no copy()), or maxParallel == 1, it runs

sequentially on the live facade. Each result carries the full evaluate payload

(converged, iterations, maxError, failedUnitName, failedUnitError) plus its

index; the root reports parallel, feasibleCount, and firstFeasibleIndex.

Maximise production and manage emissions. Combine the pieces: (1) decision space =

getAdjustableParameters() (bounded setpoints + splitter routing; bound feed flowRate

for feed-scale); (2) feasibility = enableCapacityConstraints() + the capacity snapshot

across all equipment; (3) objective = an AgenticProcessOptimizer.setObjectiveFunction

reward such as production − λ·(total compressor power) (compression shaft power is a

direct CO2 proxy for turbine-driven trains), or a ProductionOptimizer.optimizePareto

with [MAXIMIZE production, MINIMIZE Σ compressor power] to get the production-vs-emissions

trade-off front. evaluateBatchJson read-backs of each compressor's power give the

emissions term per candidate for an external Python optimizer.

**B. Transparent Python roll-up (API-risk-free, good when the separator capacity path

is not yet wired).** Merge three families into equipment_utilization(tags, sizes):

chart operating point);

(GasTurbineVendorPerformance);

~1.15 margin (see neqsim-separator-modelling), recomputing vg_max at the current

density.

single feasible flag.

Inlet-pressure lower-limit search. Parametrize the flowsheet by process/inlet

pressure (cleanest trick in a builder: add PROC_P = proc_p as a local at the top

of build_model(proc_p=PROC_P) so every internal reference picks up the argument with

one edit). Size separators once at the base (highest) pressure, then rebuild+run at each

lower pressure, evaluate equipment_utilization, and return the lowest feasible

pressure. Physics: lowering inlet pressure raises the export compression ratio and the

actual gas volume, so a scrubber gas-load or a compressor surge/power constraint becomes

the binding limit. The rebuild-per-point sweep is slow — gate it behind an env flag and

do NOT re-read live plant data inside the loop.


9. Reporting (defer to neqsim-professional-reporting)

Persist a trace of every trial and the optimum to results.json:

results = {
  "key_results": {"year": 2035, "min_compression_power_MW": power_MW,
                  "export_oil_rvp_bara": rvp, "surge_margin": surge_margin},
  "validation": {"converged": True, "rvp_spec_met": rvp <= 0.79,
                 "all_compressors_within_chart": within},
  "optimum_setpoints": best_setpoints,
  "tables": [{"title": "Per-year optimum", "headers": ["Year", "Power MW", "RVP bara", "Surge margin"],
              "rows": rows}],
}

Always plot: objective convergence trace, the active-constraint (RVP or surge)

vs the binding knob, and a per-year optimum summary. Add a discussion block per

figure (observation → mechanism → implication → recommendation).


10. Pitfalls checklist

str. json.loads(comp.getOperatingPointJson()) raises *"the JSON object must

be str, bytes or bytearray, not java.lang.String"*. If that error is swallowed by

a bare except, every trial silently reports power_MW=0.0 and surge_margin=NaN

— the objective collapses to the RVP/spec penalty and the optimizer "succeeds" on

a meaningless metric. Wrap every getXxxJson() in str(...).

band — not a strict tol=1e-4? Near-zero anti-surge recycles inflate the

relative boundary error; demand convergence too tightly and every trial is

"non-converged" even though the plant is physically settled.

last evaluate() call? The final call can hit a non-converged retry → null

power/RVP/surge in key_results.

add the relieving lever and switch to a multivariate optimizer?

Restart decisions with a shared riser and host

Use the two-well restart study

to compare a fixed platform choke with an opening trajectory. Inspect peak phase

rates, well production, separator levels, suction flow and power separately on

matched mesh, timestep and fluid cases. Check whether the largest load occurred

before or after the control move. A completed simulation or a small component

balance residual cannot establish that the peak is resolved. Ask for a paired

pressure/phase-rate trace or a compressor map when that evidence would change

the decision. For blind evaluation, give the agent only the challenge-mode MCP

server and score its saved choice separately. Review violation_evidence for the fluid,

mesh, timestep and host limit of each observed breach. A rejection on another configuration

keeps the production ranking unresolved while preserving the completed trajectories' findings.

For installed-equipment comparisons, verify the signed steady well-rate and choke-pressure residuals before starting the controllers. The reference case solves both to 1e-10 in kg/s and bar so an initialization discrepancy cannot disable the native steady momentum correction. Keep event and handoff protocol identical across a ranking. A rejected coarse trajectory also blocks selection when the fine runs happen to complete.

Use the same compressor map hash for both policies and every refinement. The optional native chart path computes the speed required by the export duty and checks the flow range and suction envelope. Record whether the chart came from a vendor or was constructed for a sensitivity case.

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.